Clinical implementation and initial experience with calypso 4D tracking system for prostate cancer treatment

被引:0
|
作者
Cao, D. [1 ]
Ye, J. [1 ]
Afghan, M. [1 ]
Wong, T. [1 ]
Shepard, D. [1 ]
机构
[1] Swedish Med Ctr, Swedish Canc Inst, Seattle, WA USA
关键词
D O I
10.1118/1.2760540
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: The Calypso 4D tracking system can detect real‐time intra‐fractional tumor motion based on RF signals from the implanted beacons. The initial clinical experience on tracking prostate motion during the treatment is reported. We performed a series of tests to evaluate the calibration accuracy and stability of the system. Material and Methods: The first FDA approved clinical Calypso 4D tracking system was installed and used for this work. With three beacons implemented in the prostate, the system reports the target location in a real time fashion. Seven patients with prostate cancer were localized/tracked using this system. The vender provided a monthly calibration phantom and an in‐house developed stereotactic cone based alignment tool that were used to test the calibration accuracy of the Calypso 4D tracking system. The system stability was also studied using the monthly calibration phantom. Results: For the seven patients treated so far, the average initial setup shifts from the external tattoos were 1.1, 2.2 and 4.0 mm along lateral, longitudinal and vertical directions, respectively. For one patient, the observed maximum shifts along the above three axes were 4.6, 10.9 and 29.2 mm. The range of target motion during treatment was found to be 3.4 (Right‐Left), 9.9 (Superior‐Inferior) and 12.3 (Anterior‐Posterior) mm. The average patient setup time was less then 5 minutes. The daily QA of the system takes around 5 minutes on average. The vender provided system calibration procedure is based on room lasers with 2 mm error tolerance, which may potentially decrease the overall system accuracy. Our stereotactic cone based alignment tool can achieve sub‐millimeter accuracy. Repeated monthly calibration procedures showed that the system stability is within 1 mm. Conclusion: Calypso system provides efficient and accurate patient setup for prostate treatment. The current calibration procedure can be improved to achieve better accuracy. © 2007, American Association of Physicists in Medicine. All rights reserved.
引用
收藏
页码:2376 / 2376
页数:1
相关论文
共 50 条
  • [31] The role of phosphodiesterase 4D and the microenvironment in prostate cancer
    Powers, Ginny L.
    Hammer, Kimberly D. P.
    Su, Xiaojing
    Domenech, Maribella
    Beebe, David J.
    Marker, Paul C.
    CANCER RESEARCH, 2013, 73
  • [32] A Phase II Trial of Real-time Target Tracking SBRT for Low-risk Prostate Cancer Utilizing the Calypso 4D Localization System: Patient-reported Quality of Life and Toxicity Outcomes
    Mantz, C. A.
    Fernandez, E.
    Zucker, I.
    Harrison, S.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2011, 81 (02): : S100 - S100
  • [33] 4D Imaging Experience for Treatment of Lung SBRT
    Hassan, S.
    Dobson, J.
    CLINICAL ONCOLOGY, 2018, 30 (06) : E59 - E59
  • [34] MR Spectroscopy of prostate cancer. Initial clinical experience
    Squillaci, E
    Manenti, G
    Mancino, S
    Carlani, M
    Di Roma, M
    Colangelo, V
    Simonetti, G
    JOURNAL OF EXPERIMENTAL & CLINICAL CANCER RESEARCH, 2005, 24 (04) : 523 - 530
  • [35] Performance Evaluation of Calypso® 4D Localization and Kilovoltage Image Guidance Systems for Interfraction Motion Management of Prostate Patients
    Ogunleye, Tomi
    Rossi, Peter J.
    Jani, Ashesh B.
    Fox, Tim
    Elder, Eric
    THESCIENTIFICWORLDJOURNAL, 2009, 9 : 449 - 458
  • [36] Clinical Implementation of Triggered Imaging for Prostate SBRT Motion Management: An Initial Experience
    Dong, H.
    Neylon, J. P.
    Tenn, S. E.
    Lamb, J. M.
    Valle, L.
    Steinberg, M. L.
    Kishan, A. U.
    Cao, M.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2024, 120 (02): : E118 - E118
  • [37] Image-guided 4D radiotherapy for prostate cancer
    Lebesque, J.
    EJC SUPPLEMENTS, 2007, 5 (04): : 42 - 43
  • [38] Comparison of Lung Tumor Motion Profiles From 4D CT and a Treatment Tracking System
    Yu, N.
    Chuang, C.
    Gottschalk, A.
    Yom, S.
    Xia, P.
    MEDICAL PHYSICS, 2009, 36 (06)
  • [39] Implementation and experimental results of 4D tumor tracking using robotic couch
    Buzurovic, I.
    Yu, Y.
    Werner-Wasik, M.
    Biswas, T.
    Anne, P. R.
    Dicker, A. P.
    Podder, T. K.
    MEDICAL PHYSICS, 2012, 39 (11) : 6957 - 6967
  • [40] Analysis and circuit implementation of a new 4D chaotic system
    Qi, GY
    Chen, GR
    PHYSICS LETTERS A, 2006, 352 (4-5) : 386 - 397