Clinical implementation and initial experience with calypso 4D tracking system for prostate cancer treatment

被引:0
|
作者
Cao, D. [1 ]
Ye, J. [1 ]
Afghan, M. [1 ]
Wong, T. [1 ]
Shepard, D. [1 ]
机构
[1] Swedish Med Ctr, Swedish Canc Inst, Seattle, WA USA
关键词
D O I
10.1118/1.2760540
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: The Calypso 4D tracking system can detect real‐time intra‐fractional tumor motion based on RF signals from the implanted beacons. The initial clinical experience on tracking prostate motion during the treatment is reported. We performed a series of tests to evaluate the calibration accuracy and stability of the system. Material and Methods: The first FDA approved clinical Calypso 4D tracking system was installed and used for this work. With three beacons implemented in the prostate, the system reports the target location in a real time fashion. Seven patients with prostate cancer were localized/tracked using this system. The vender provided a monthly calibration phantom and an in‐house developed stereotactic cone based alignment tool that were used to test the calibration accuracy of the Calypso 4D tracking system. The system stability was also studied using the monthly calibration phantom. Results: For the seven patients treated so far, the average initial setup shifts from the external tattoos were 1.1, 2.2 and 4.0 mm along lateral, longitudinal and vertical directions, respectively. For one patient, the observed maximum shifts along the above three axes were 4.6, 10.9 and 29.2 mm. The range of target motion during treatment was found to be 3.4 (Right‐Left), 9.9 (Superior‐Inferior) and 12.3 (Anterior‐Posterior) mm. The average patient setup time was less then 5 minutes. The daily QA of the system takes around 5 minutes on average. The vender provided system calibration procedure is based on room lasers with 2 mm error tolerance, which may potentially decrease the overall system accuracy. Our stereotactic cone based alignment tool can achieve sub‐millimeter accuracy. Repeated monthly calibration procedures showed that the system stability is within 1 mm. Conclusion: Calypso system provides efficient and accurate patient setup for prostate treatment. The current calibration procedure can be improved to achieve better accuracy. © 2007, American Association of Physicists in Medicine. All rights reserved.
引用
收藏
页码:2376 / 2376
页数:1
相关论文
共 50 条
  • [21] Investigation Of Calypso 4D As A Respiratory Gating System For EBRT For Pancreatic Cancer By Correlating The Pancreatic Movement Using Calypso 4D With The Relative Breathing Motion Obtained By Anzai Motion Monitoring System
    Betancourt, R.
    Plastaras, J.
    Metz, J.
    Kassaee, A.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2011, 81 (02): : S787 - S788
  • [22] Tracking prostate motion and isocenter offset during treatment using the Calypos(tm) 4D Localization System
    Willoughby, T
    Kupelian, P
    Litzenberg, D
    Sandler, H
    Levine, L
    Dimmer, S
    MEDICAL PHYSICS, 2005, 32 (06) : 2133 - 2133
  • [23] 4D radiation therapy for prostate cancer
    Li, Jin Sheng
    Ma, Chang-Ming
    INTERNATIONAL JOURNAL OF BIOMEDICAL ENGINEERING AND TECHNOLOGY, 2012, 8 (2-3) : 138 - 150
  • [24] 4D verification of real-time accuracy of the Calypso system with lung cancer patient trajectory data
    Parikh, P
    Hubenschmidt, J
    Dimmer, S
    Vertatschitsch, E
    Eidens, R
    Wright, JN
    Low, DA
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2005, 63 (02): : S26 - S27
  • [25] Clinical implementation: 4D computed tomography for thoracic tumor treatment planning
    Rietzel, E
    Liu, AK
    Chen, GT
    Doppke, KP
    Choi, NC
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2004, 60 (01): : S609 - S610
  • [26] Validation of 4D dose calculation using an independent motion monitoring by the calypso tracking system and 3D polymer gel dosimetry
    Mann, P.
    Saito, N.
    Lang, C.
    Runz, A.
    Johnen, W.
    Witte, M.
    Schmitt, D.
    Karger, C. P.
    9TH INTERNATIONAL CONFERENCE ON 3D RADIATION DOSIMETRY, 2017, 847
  • [27] Verification of Prostate VMAT Treatment Plans Using the Octavius 4D System
    Stelljes, T. S.
    Looe, H. K.
    Willborn, K.
    Poppe, B.
    MEDICAL PHYSICS, 2013, 40 (06)
  • [28] A Comparative Study for Daily Localization with 3D Ultrasound, Cone Beam CT, Implanted Prostate Fiducial Markers and Calypso 4D Localization System for Patients Undergoing IGRT for Prostate Cancer
    Neicu, T.
    Ren, L.
    Chetty, I.
    Pradhan, D.
    Stricker, H.
    Movsas, B.
    Elshaikh, M.
    MEDICAL PHYSICS, 2010, 37 (06)
  • [29] Acceptance Testing and Quality-Assurance Protocols for the Calypso® 4D Localization System™ and Q-Fix®/Calypso® Couchtop
    O'Daniel, J.
    Wu, Q. J.
    McMahon, R.
    Maurer, J.
    Lee, W. R.
    Yin, F.
    MEDICAL PHYSICS, 2009, 36 (06)
  • [30] Clinical implementation of 4D dynamic Arc therapy
    Yang, Y
    Scheibmann, E
    Li, T
    Xing, L
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2005, 63 (02): : S563 - S564