Effect of a lung recruitment maneuver by high-frequency oscillatory ventilation in experimental acute lung injury on organ blood flow in pigs

被引:10
|
作者
David, Matthias [1 ]
Gervais, Hendrik W.
Karmrodt, Jens
Depta, Arno L.
Kempski, Oliver
Markstaller, Klaus
机构
[1] Johannes Gutenberg Univ Mainz, Dept Anesthesiol, D-6500 Mainz, Germany
[2] Johannes Gutenberg Univ Mainz, Inst Neurosurg Pathophysiol, D-6500 Mainz, Germany
来源
CRITICAL CARE | 2006年 / 10卷 / 04期
关键词
D O I
10.1186/cc4967
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Introduction The objective was to study the effects of a lung recruitment procedure by stepwise increases of mean airway pressure upon organ blood flow and hemodynamics during high-frequency oscillatory ventilation (HFOV) versus pressure-controlled ventilation (PCV) in experimental lung injury. Methods Lung damage was induced by repeated lung lavages in seven anesthetized pigs (23-26 kg). In randomized order, HFOV and PCV were performed with a fixed sequence of mean airway pressure increases (20, 25, and 30 mbar every 30 minutes). The transpulmonary pressure, systemic hemodynamics, intracranial pressure, cerebral perfusion pressure, organ blood flow (fluorescent microspheres), arterial and mixed venous blood gases, and calculated pulmonary shunt were determined at each mean airway pressure setting. Results The transpulmonary pressure increased during lung recruitment (HFOV, from 15 +/- 3 mbar to 22 +/- 2 mbar, P < 0.05; PCV, from 15 +/- 3 mbar to 23 +/- 2 mbar, P < 0.05), and high airway pressures resulted in elevated left ventricular end-diastolic pressure (HFOV, from 3 +/- 1 mmHg to 6 +/- 3 mmHg, P < 0.05; PCV, from 2 +/- 1 mmHg to 7 +/- 3 mmHg, P < 0.05), pulmonary artery occlusion pressure (HFOV, from 12 +/- 2 mmHg to 16 +/- 2 mmHg, P < 0.05; PCV, from 13 +/- 2 mmHg to 15 +/- 2 mmHg, P < 0.05), and intracranial pressure (HFOV, from 14 +/- 2 mmHg to 16 +/- 2 mmHg, P < 0.05; PCV, from 15 +/- 3 mmHg to 17 +/- 2 mmHg, P < 0.05). Simultaneously, the mean arterial pressure (HFOV, from 89 +/- 7 mmHg to 79 +/- 9 mmHg, P < 0.05; PCV, from 91 +/- 8 mmHg to 81 +/- 8 mmHg, P < 0.05), cardiac output (HFOV, from 3.9 +/- 0.4 l/minute to 3.5 +/- 0.3 l/minute, P < 0.05; PCV, from 3.8 +/- 0.6 l/minute to 3.4 +/- 0.3 l/minute, P < 0.05), and stroke volume (HFOV, from 32 +/- 7 ml to 28 +/- 5 ml, P < 0.05; PCV, from 31 +/- 2 ml to 26 +/- 4 ml, P < 0.05) decreased. Blood flows to the heart, brain, kidneys and jejunum were maintained. Oxygenation improved and the pulmonary shunt fraction decreased below 10% (HFOV, P < 0.05; PCV, P < 0.05). We detected no differences between HFOV and PCV at comparable transpulmonary pressures. Conclusion A typical recruitment procedure at the initiation of HFOV improved oxygenation but also decreased systemic hemodynamics at high transpulmonary pressures when no changes of vasoactive drugs and fluid management were performed. Blood flow to the organs was not affected during lung recruitment. These effects were independent of the ventilator mode applied.
引用
收藏
页数:10
相关论文
共 50 条
  • [41] Helix improves gas exchange during high-frequency oscillatory ventilation in a pediatric model of acute lung injury
    Katz, AL
    Gentile, MA
    Craig, DM
    Quick, G
    Meliones, JN
    Cheifetz, IM
    CRITICAL CARE MEDICINE, 2000, 28 (12) : A31 - A31
  • [42] High-frequency oscillatory ventilation: a better tool for lung protection?
    H Gönençer
    N Ünal
    M Oral
    M Tulunay
    Critical Care, 8 (Suppl 1):
  • [43] Combining lung-protective strategies in experimental acute lung injury: The impact of high-frequency partial liquid ventilation
    Rotta, Alexandre T.
    Viana, Mario Eduardo G.
    Wiryawan, Budi
    Sargentelli, Guilherme A.
    Dowhy, Mark S.
    Zin, Walter A.
    Fuhrman, Bradley P.
    PEDIATRIC CRITICAL CARE MEDICINE, 2006, 7 (06) : 562 - 570
  • [44] High-frequency oscillatory ventilation and partial liquid ventilation after acute lung injury in premature lambs with respiratory distress syndrome
    Göthberg, S
    Parker, TA
    Abman, SH
    Kinsella, JP
    CRITICAL CARE MEDICINE, 2000, 28 (07) : 2450 - 2456
  • [45] High-frequency oscillatory ventilation of the perfluorocarbon-filled lung: Dose-response relationships in an animal model of acute lung injury
    Doctor, A
    Price, B
    Bhargava, N
    DiCanzio, J
    Arnold, JH
    CRITICAL CARE MEDICINE, 2001, 29 (04) : 847 - 854
  • [46] LUNG-VOLUME RECRUITMENT DURING HIGH-FREQUENCY VENTILATION
    BRYAN, AC
    JOURNAL OF PEDIATRICS, 1990, 116 (02): : 317 - 317
  • [47] Mean Lung Pressure during Adult High-Frequency Oscillatory Ventilation: An Experimental Study Using a Lung Model
    Hirayama, Takahiro
    Nagano, Osamu
    Shiba, Naoki
    Yumoto, Tetsuya
    Sato, Keiji
    Terado, Michihisa
    Ugawa, Toyomu
    Ichiba, Shingo
    Ujike, Yoshihito
    ACTA MEDICA OKAYAMA, 2014, 68 (06) : 323 - 329
  • [48] Lung volume recruitment in lambs during high-frequency oscillatory ventilation using respiratory inductive plethysmography
    Göthberg, S
    Parker, TA
    Griebel, J
    Abman, SH
    Kinsella, JP
    PEDIATRIC RESEARCH, 2001, 49 (01) : 38 - 44
  • [49] Lung volume recruitment in lambs during high-frequency oscillatory ventilation using respiratory inductive plethysmography
    Göthberg S.
    Parker T.A.
    Griebel J.
    Abman S.H.
    Kinsella J.P.
    Pediatric Research, 2001, 49 (1) : 38 - 44
  • [50] OXYGENATION DURING VENTILATION BY HIGH-FREQUENCY OSCILLATION IN DOGS WITH ACUTE LUNG INJURY
    MANSEL, JK
    GILLESPIE, DJ
    CRITICAL CARE MEDICINE, 1986, 14 (11) : 955 - 959