High-frequency oscillatory ventilation of the perfluorocarbon-filled lung: Dose-response relationships in an animal model of acute lung injury

被引:12
|
作者
Doctor, A
Price, B
Bhargava, N
DiCanzio, J
Arnold, JH
机构
[1] Childrens Hosp, Crit Care Res Labs, Boston, MA 02115 USA
[2] Childrens Hosp, Dept Anesthesia & Res Computat & Biostat, Boston, MA 02115 USA
[3] Harvard Univ, Sch Med, Boston, MA USA
关键词
partial liquid ventilation; acute respiratory distress syndrome; acute lung injury; mechanical ventilation; high-frequency oscillatory ventilation; saline lavage; pulmonary gas exchange; perfluorochemical;
D O I
10.1097/00003246-200104000-00033
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Objective: To examine dose-response relationships regarding the efficiency of gas exchange and hemodynamic function during high-frequency oscillation and partial liquid ventilation (HF0-PLV) of the perfluorocarbon (PFC)-treated lung in a model of acute lung injury. Setting: An animal research laboratory in a university medical center. Design:A prospective, randomized study comparing animals receiving varying doses (0, 5, 15, and 20 mL/kg) of perflubron during high-frequency oscillatory ventilation (HF0V) with mean airway pressure (Paw) optimized to achieve a minimal percutaneous oxygen saturation (Spo(2)). Subjects: Nineteen healthy swine (mean weight 28.9 kg) with saline lavage-induced acute lung injury. Methods: Animals were treated with repetitive saline lavage to achieve a uniform degree of acute lung injury (Spo(2) less than or equal to 90% on an Flo(2) of 1.0). After lung injury, subjects were converted to HFOV, and lung volume was optimized. HFO-PLV was initiated by instillation of perflubron at a rate of 0.5 mL.kg(-1).min(-1) to achieve total doses of 5, 15, and 20 mL/kg. After PFC dosing, the only experimental manipulation consisted of adjustment of Paw to achieve an Spo(2) of 90% +/- 2% with Flo(2) of 0.6. Gas exchange, hemodynamic variables, and pulmonary mechanics data were collected over a 1-hr period. Five control animals were not dosed with perflubron and remained on HFOV for the 1-hr period of data collection. Measurements and Main Results:After lung volume recruitment with HFOV, the initiation of HFO-PLV was best tolerated with the two lower doses in our protocol. There were essentially no changes in Pace, or ph between groups over the dosing interval. After dosing, analysis of variance demonstrated a PFC dose-dependent effect for oxygenation index (p = .01) only; the lowest oxygenation index was found in the 15 mL/kg group (p = .01). In the 15 mL/kg group, the Paw decreased steadily from 20.6 +/- 3.4 cm H2O at the end of dosing to 18.0 +/- 4.9 cm H2O at 60 mins. The Pao(2) increased from 113 +/- 51 torr (15.06 +/- 6.79 kPa) to 134 +/- 49 torr (17.86 +/- 6.53 kPa) during this period and was associated with a decreasing oxygenation index (from 11.4 +/- 2.0 to 9.3 +/- 1.5). The cardiac index and pulmonary vascular resistance did not change significantly during the dosing period and were relatively stable after the completion of dosing. Conclusions:The combination of HFOV and perflubron administration was well tolerated hemodynamically and was not associated with deterioration of gas exchange during dosing. Our data suggest that the optimal dose of perflubron to achieve the lowest oxygenation index during HFO-PLV is between 5 and 15 mL/kg. The combination of HFOV and perflubron administration is a novel strategy in the treatment of acute lung injury that shows some promise and merits additional investigation. We hope in future studies to address the histopathologic effects of varying perflubron doses during HFOV in a long-term study of the lung-protective effects of HFO-PLV.
引用
收藏
页码:847 / 854
页数:8
相关论文
共 50 条
  • [1] High-frequency oscillatory ventilation of the perfluorocarbon-filled lung: Preliminary results in an animal model of acute lung injury
    Doctor, A
    Mazzoni, MC
    DelBalzo, U
    DiCanzio, J
    Arnold, JH
    [J]. CRITICAL CARE MEDICINE, 1999, 27 (11) : 2500 - 2507
  • [2] High Frequency Oscillatory Ventilation of the Perfluorocarbon-Filled Lung: Preliminary Results in an Animal Model of Acute Lung Injury ♦ 177
    Allan Doctor
    Michelle Mazzoni
    Ughetta DelBalzo
    John H Arnold
    [J]. Pediatric Research, 1997, 41 (Suppl 4) : 32 - 32
  • [3] Histopathology of Acute Lung Injury: High Frequency Oscillation of the Perfluorocarbon-Filled Lung ♦ 178
    Allan Doctor
    Michelle Mazzoni
    Ughetta DelBalzo
    John H Arnold
    [J]. Pediatric Research, 1997, 41 (Suppl 4) : 32 - 32
  • [4] High-frequency oscillatory ventilation attenuates oxidative lung injury in a rabbit model of acute lung injury
    Ronchi, Carlos Fernando
    dos Anjos Ferreira, Ana Lucia
    Campos, Fabio Joly
    Kurokawa, Cilmery Suemi
    Carpi, Mario Ferreira
    de Moraes, Marcos Aurelio
    Bonatto, Rossano Cesar
    Defaveri, Julio
    Yeum, Kyung-Jin
    Fioretto, Jose Roberto
    [J]. EXPERIMENTAL BIOLOGY AND MEDICINE, 2011, 236 (10) : 1188 - 1196
  • [5] Bias flow does not affect ventilation during high-frequency oscillatory ventilation in a pediatric animal model of acute lung injury
    Turner, David A.
    Adams, David F.
    Gentile, Michael A.
    Williford, Lee
    Quick, George A.
    Smith, P. Brian
    Cheifetz, Ira M.
    [J]. PEDIATRIC CRITICAL CARE MEDICINE, 2012, 13 (02) : E108 - E112
  • [6] New therapies for adults with acute lung injury - High-frequency oscillatory ventilation
    Ferguson, ND
    Stewart, TE
    [J]. CRITICAL CARE CLINICS, 2002, 18 (01) : 91 - +
  • [7] Independent high-frequency oscillatory ventilation in the management of asymmetric acute lung injury
    Terragni, P
    Rosboch, GL
    Corno, E
    Menaldo, E
    Tealdi, A
    Borasio, P
    Davini, O
    Viale, AG
    Ranieri, VM
    [J]. ANESTHESIA AND ANALGESIA, 2005, 100 (06): : 1793 - 1796
  • [8] HIGH-FREQUENCY VENTILATION IN ACUTE LUNG INJURY
    ARMENGOL, J
    [J]. BRITISH JOURNAL OF ANAESTHESIA, 1989, 63 : S11 - S15
  • [9] PRONE POSITIONING ATTENUATES LUNG INFLAMMATORY INJURY IN AN ACUTE LUNG INJURY MODEL IN RABBITS UNDER HIGH-FREQUENCY OSCILLATORY VENTILATION
    Fioretto, Jose
    Batistella, Rafaelle
    Bonatto, Rossano
    Carpi, Mario
    Kurokawa, Cilmery
    Moraes, Marcos
    [J]. CRITICAL CARE MEDICINE, 2010, 38 (12) : U47 - U47
  • [10] Cardiovascular responses to high-frequency oscillatory ventilation during acute lung injury in sheep
    Nakagawa, Rikimaru
    Koizumi, Tomonobu
    Ono, Koichi
    Tsushima, Kenji
    Yoshikawa, Sumiko
    Kubo, Keishi
    Otagiri, Tetutarou
    [J]. JOURNAL OF ANESTHESIA, 2007, 21 (03) : 340 - 347