High-frequency oscillatory ventilation of the perfluorocarbon-filled lung: Dose-response relationships in an animal model of acute lung injury

被引:12
|
作者
Doctor, A
Price, B
Bhargava, N
DiCanzio, J
Arnold, JH
机构
[1] Childrens Hosp, Crit Care Res Labs, Boston, MA 02115 USA
[2] Childrens Hosp, Dept Anesthesia & Res Computat & Biostat, Boston, MA 02115 USA
[3] Harvard Univ, Sch Med, Boston, MA USA
关键词
partial liquid ventilation; acute respiratory distress syndrome; acute lung injury; mechanical ventilation; high-frequency oscillatory ventilation; saline lavage; pulmonary gas exchange; perfluorochemical;
D O I
10.1097/00003246-200104000-00033
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Objective: To examine dose-response relationships regarding the efficiency of gas exchange and hemodynamic function during high-frequency oscillation and partial liquid ventilation (HF0-PLV) of the perfluorocarbon (PFC)-treated lung in a model of acute lung injury. Setting: An animal research laboratory in a university medical center. Design:A prospective, randomized study comparing animals receiving varying doses (0, 5, 15, and 20 mL/kg) of perflubron during high-frequency oscillatory ventilation (HF0V) with mean airway pressure (Paw) optimized to achieve a minimal percutaneous oxygen saturation (Spo(2)). Subjects: Nineteen healthy swine (mean weight 28.9 kg) with saline lavage-induced acute lung injury. Methods: Animals were treated with repetitive saline lavage to achieve a uniform degree of acute lung injury (Spo(2) less than or equal to 90% on an Flo(2) of 1.0). After lung injury, subjects were converted to HFOV, and lung volume was optimized. HFO-PLV was initiated by instillation of perflubron at a rate of 0.5 mL.kg(-1).min(-1) to achieve total doses of 5, 15, and 20 mL/kg. After PFC dosing, the only experimental manipulation consisted of adjustment of Paw to achieve an Spo(2) of 90% +/- 2% with Flo(2) of 0.6. Gas exchange, hemodynamic variables, and pulmonary mechanics data were collected over a 1-hr period. Five control animals were not dosed with perflubron and remained on HFOV for the 1-hr period of data collection. Measurements and Main Results:After lung volume recruitment with HFOV, the initiation of HFO-PLV was best tolerated with the two lower doses in our protocol. There were essentially no changes in Pace, or ph between groups over the dosing interval. After dosing, analysis of variance demonstrated a PFC dose-dependent effect for oxygenation index (p = .01) only; the lowest oxygenation index was found in the 15 mL/kg group (p = .01). In the 15 mL/kg group, the Paw decreased steadily from 20.6 +/- 3.4 cm H2O at the end of dosing to 18.0 +/- 4.9 cm H2O at 60 mins. The Pao(2) increased from 113 +/- 51 torr (15.06 +/- 6.79 kPa) to 134 +/- 49 torr (17.86 +/- 6.53 kPa) during this period and was associated with a decreasing oxygenation index (from 11.4 +/- 2.0 to 9.3 +/- 1.5). The cardiac index and pulmonary vascular resistance did not change significantly during the dosing period and were relatively stable after the completion of dosing. Conclusions:The combination of HFOV and perflubron administration was well tolerated hemodynamically and was not associated with deterioration of gas exchange during dosing. Our data suggest that the optimal dose of perflubron to achieve the lowest oxygenation index during HFO-PLV is between 5 and 15 mL/kg. The combination of HFOV and perflubron administration is a novel strategy in the treatment of acute lung injury that shows some promise and merits additional investigation. We hope in future studies to address the histopathologic effects of varying perflubron doses during HFOV in a long-term study of the lung-protective effects of HFO-PLV.
引用
收藏
页码:847 / 854
页数:8
相关论文
共 50 条
  • [31] High frequency oscillatory ventilation (HFOV) as therapy for acute lung injury and ARDS
    Luecke, T
    Herrmann, P
    Quintel, M
    [J]. ANAESTHESIST, 2000, 49 (11): : 972 - 980
  • [32] High-frequency oscillatory ventilation combined with partial liquid ventilation in experimental lung injury: effects on lung cell apoptosis
    Zuo, Huimin
    Zeng, Linxiang
    Guo, Guanghua
    Zeng, Huihong
    [J]. WIENER KLINISCHE WOCHENSCHRIFT, 2015, 127 (15-16) : 606 - 611
  • [33] Higher Frequency Ventilation Attenuates Lung Injury during High-frequency Oscillatory Ventilation in Sheep Models of Acute Respiratory Distress Syndrome
    Liu, Songqiao
    Yi, Yang
    Wang, Maohua
    Chen, Qiuhua
    Huang, Yingzi
    Liu, Ling
    Xie, Jianfeng
    Zhou, Dunyuan
    Qiu, Haibo
    [J]. ANESTHESIOLOGY, 2013, 119 (02) : 398 - 411
  • [34] Inflammatory lung injury in rabbits: effects of high-frequency oscillatory ventilation in the prone position
    Fioretto, Jose Roberto
    Pires, Rafaelle Batistella
    Klefens, Susiane Oliveira
    Kurokawa, Cilmery Suemi
    Carpi, Mario Ferreira
    Bonatto, Rossano Cesar
    Moraes, Marcos Aurelio
    Ronchit, Carlos Fernando
    [J]. JORNAL BRASILEIRO DE PNEUMOLOGIA, 2019, 45 (05)
  • [35] High-frequency oscillatory ventilation: a better tool for lung protection?
    H Gönençer
    N Ünal
    M Oral
    M Tulunay
    [J]. Critical Care, 8 (Suppl 1):
  • [36] High-frequency oscillatory ventilation and partial liquid ventilation after acute lung injury in premature lambs with respiratory distress syndrome
    Göthberg, S
    Parker, TA
    Abman, SH
    Kinsella, JP
    [J]. CRITICAL CARE MEDICINE, 2000, 28 (07) : 2450 - 2456
  • [37] Spontaneous breathing during high-frequency oscillatory ventilation improves regional lung characteristics in experimental lung injury
    van Heerde, M.
    Roubik, K.
    Kopelent, V.
    Kneyber, M. C. J.
    Markhorst, D. G.
    [J]. ACTA ANAESTHESIOLOGICA SCANDINAVICA, 2010, 54 (10) : 1248 - 1256
  • [38] High frequency oscillatory and conventional ventilation, exogenous surfactant, and partial liquid ventilation: Effect of prolonged treatment on lung pathology in an animal lung injury model
    Manaligod, JM
    Bendel-Stenzel, EM
    Smith, KM
    Simonton, SC
    Bing, DR
    Meyers, PA
    Connett, JE
    Mammel, MC
    [J]. PEDIATRIC RESEARCH, 1999, 45 (04) : 311A - 311A
  • [39] High Frequency Oscillatory and Conventional Ventilation, Exogenous Surfactant, and Partial Liquid Ventilation: Effect of Prolonged Treatment on Lung Pathology in an Animal Lung Injury Model
    Joel M Manaligod
    Ellen M Bendel-Stenzel
    Kendra M Smith
    Susan C Simonton
    Dennis R Bing
    Pat A Meyers
    John E Connett
    Mark C Mammel
    [J]. Pediatric Research, 1999, 45 (7) : 311 - 311
  • [40] Combination of arteriovenous extracorporeal lung assist and high-frequency oscillatory ventilation in a porcine model of lavage-induced acute lung injury: A randomized controlled trial
    Brederlau, Joerg
    Muellenbach, Ralf
    Kredel, Markus
    Kuestermann, Julian
    Anetseder, Martin
    Greim, Clemens
    Roewer, Norbert
    [J]. JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE, 2007, 62 (02): : 336 - 345