Effect of a lung recruitment maneuver by high-frequency oscillatory ventilation in experimental acute lung injury on organ blood flow in pigs

被引:10
|
作者
David, Matthias [1 ]
Gervais, Hendrik W.
Karmrodt, Jens
Depta, Arno L.
Kempski, Oliver
Markstaller, Klaus
机构
[1] Johannes Gutenberg Univ Mainz, Dept Anesthesiol, D-6500 Mainz, Germany
[2] Johannes Gutenberg Univ Mainz, Inst Neurosurg Pathophysiol, D-6500 Mainz, Germany
来源
CRITICAL CARE | 2006年 / 10卷 / 04期
关键词
D O I
10.1186/cc4967
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Introduction The objective was to study the effects of a lung recruitment procedure by stepwise increases of mean airway pressure upon organ blood flow and hemodynamics during high-frequency oscillatory ventilation (HFOV) versus pressure-controlled ventilation (PCV) in experimental lung injury. Methods Lung damage was induced by repeated lung lavages in seven anesthetized pigs (23-26 kg). In randomized order, HFOV and PCV were performed with a fixed sequence of mean airway pressure increases (20, 25, and 30 mbar every 30 minutes). The transpulmonary pressure, systemic hemodynamics, intracranial pressure, cerebral perfusion pressure, organ blood flow (fluorescent microspheres), arterial and mixed venous blood gases, and calculated pulmonary shunt were determined at each mean airway pressure setting. Results The transpulmonary pressure increased during lung recruitment (HFOV, from 15 +/- 3 mbar to 22 +/- 2 mbar, P < 0.05; PCV, from 15 +/- 3 mbar to 23 +/- 2 mbar, P < 0.05), and high airway pressures resulted in elevated left ventricular end-diastolic pressure (HFOV, from 3 +/- 1 mmHg to 6 +/- 3 mmHg, P < 0.05; PCV, from 2 +/- 1 mmHg to 7 +/- 3 mmHg, P < 0.05), pulmonary artery occlusion pressure (HFOV, from 12 +/- 2 mmHg to 16 +/- 2 mmHg, P < 0.05; PCV, from 13 +/- 2 mmHg to 15 +/- 2 mmHg, P < 0.05), and intracranial pressure (HFOV, from 14 +/- 2 mmHg to 16 +/- 2 mmHg, P < 0.05; PCV, from 15 +/- 3 mmHg to 17 +/- 2 mmHg, P < 0.05). Simultaneously, the mean arterial pressure (HFOV, from 89 +/- 7 mmHg to 79 +/- 9 mmHg, P < 0.05; PCV, from 91 +/- 8 mmHg to 81 +/- 8 mmHg, P < 0.05), cardiac output (HFOV, from 3.9 +/- 0.4 l/minute to 3.5 +/- 0.3 l/minute, P < 0.05; PCV, from 3.8 +/- 0.6 l/minute to 3.4 +/- 0.3 l/minute, P < 0.05), and stroke volume (HFOV, from 32 +/- 7 ml to 28 +/- 5 ml, P < 0.05; PCV, from 31 +/- 2 ml to 26 +/- 4 ml, P < 0.05) decreased. Blood flows to the heart, brain, kidneys and jejunum were maintained. Oxygenation improved and the pulmonary shunt fraction decreased below 10% (HFOV, P < 0.05; PCV, P < 0.05). We detected no differences between HFOV and PCV at comparable transpulmonary pressures. Conclusion A typical recruitment procedure at the initiation of HFOV improved oxygenation but also decreased systemic hemodynamics at high transpulmonary pressures when no changes of vasoactive drugs and fluid management were performed. Blood flow to the organs was not affected during lung recruitment. These effects were independent of the ventilator mode applied.
引用
收藏
页数:10
相关论文
共 50 条
  • [21] Lung recruitment in neonatal high-frequency oscillatory ventilation with volume-guarantee
    Solis-Garcia, Gonzalo
    Gonzalez-Pacheco, Noelia
    Ramos-Navarro, Cristina
    Vigil-Vazquez, Sara
    Gutierrez-Velez, Ana
    Merino-Hernandez, Amaia
    Sanchez De la Blanca, Ana Rodriguez
    Sanchez-Luna, Manuel
    PEDIATRIC PULMONOLOGY, 2022, 57 (12) : 3000 - 3008
  • [22] Bias flow does not affect ventilation during high-frequency oscillatory ventilation in a pediatric animal model of acute lung injury
    Turner, David A.
    Adams, David F.
    Gentile, Michael A.
    Williford, Lee
    Quick, George A.
    Smith, P. Brian
    Cheifetz, Ira M.
    PEDIATRIC CRITICAL CARE MEDICINE, 2012, 13 (02) : E108 - E112
  • [23] MERCURY INHALATION POISONING AND ACUTE LUNG INJURY IN A CHILD - USE OF HIGH-FREQUENCY OSCILLATORY VENTILATION
    MOROMISATO, DY
    ANAS, NG
    GOODMAN, G
    CHEST, 1994, 105 (02) : 613 - 615
  • [24] PRONE POSITIONING ATTENUATES LUNG INFLAMMATORY INJURY IN AN ACUTE LUNG INJURY MODEL IN RABBITS UNDER HIGH-FREQUENCY OSCILLATORY VENTILATION
    Fioretto, Jose
    Batistella, Rafaelle
    Bonatto, Rossano
    Carpi, Mario
    Kurokawa, Cilmery
    Moraes, Marcos
    CRITICAL CARE MEDICINE, 2010, 38 (12) : U47 - U47
  • [25] High-frequency oscillatory ventilation versus conventional ventilation in pediatric patients with acute lung injury: outcomes evaluation
    Ahmed R. Rezk
    Mai A. Mohamed
    Mohamed H. Elkenawy
    Nehad Bakry
    Ahmed Omran
    Egyptian Pediatric Association Gazette, 70
  • [26] High-frequency oscillatory ventilation versus conventional ventilation in pediatric patients with acute lung injury: outcomes evaluation
    Rezk, Ahmed R. R.
    Mohamed, Mai A. A.
    Elkenawy, Mohamed H. H.
    Bakry, Nehad
    Omran, Ahmed
    EGYPTIAN PEDIATRIC ASSOCIATION GAZETTE, 2022, 70 (01)
  • [27] High-frequency oscillatory ventilation of the perfluorocarbon-filled lung: Preliminary results in an animal model of acute lung injury
    Doctor, A
    Mazzoni, MC
    DelBalzo, U
    DiCanzio, J
    Arnold, JH
    CRITICAL CARE MEDICINE, 1999, 27 (11) : 2500 - 2507
  • [28] High-frequency ventilation for acute traumatic and nontraumatic lung injury
    R Varutti
    R Bigai
    M Fiorillo
    D Tomasello
    W Mercante
    G Trillò
    Critical Care, 17 (Suppl 2):
  • [29] THE EFFECT OF HIGH-FREQUENCY OSCILLATORY VENTILATION ON EXTRAVASCULAR LUNG WATER IN THE RABBIT
    RITCHIE, BC
    BRODECKY, V
    SCOTT, A
    WILKINSON, MH
    CLINICAL AND EXPERIMENTAL PHARMACOLOGY AND PHYSIOLOGY, 1986, 13 (11-12) : 811 - 817
  • [30] Physiologic responses to a staircase lung volume optimization maneuver in pediatric high-frequency oscillatory ventilation
    Pauline de Jager
    Johannes G. M. Burgerhof
    Alette A. Koopman
    Dick G. Markhorst
    Martin C. J. Kneyber
    Annals of Intensive Care, 10