Screening of agrochemicals in foodstuffs using low-temperature plasma (LTP) ambient ionization mass spectrometry
被引:93
|
作者:
Wiley, Joshua S.
论文数: 0引用数: 0
h-index: 0
机构:
Purdue Univ, Dept Chem, W Lafayette, IN 47907 USA
Purdue Univ, Ctr Analyt Instrumentat Dev, W Lafayette, IN 47907 USAPurdue Univ, Dept Chem, W Lafayette, IN 47907 USA
Wiley, Joshua S.
[1
,2
]
Garcia-Reyes, Juan F.
论文数: 0引用数: 0
h-index: 0
机构:
Purdue Univ, Dept Chem, W Lafayette, IN 47907 USA
Purdue Univ, Ctr Analyt Instrumentat Dev, W Lafayette, IN 47907 USA
Univ Jaen, Analyt Chem Res Grp, Dept Phys & Analyt Chem, Jaen 23071, SpainPurdue Univ, Dept Chem, W Lafayette, IN 47907 USA
Garcia-Reyes, Juan F.
[1
,2
,4
]
Harper, Jason D.
论文数: 0引用数: 0
h-index: 0
机构:
Purdue Univ, Dept Chem, W Lafayette, IN 47907 USA
Purdue Univ, Ctr Analyt Instrumentat Dev, W Lafayette, IN 47907 USAPurdue Univ, Dept Chem, W Lafayette, IN 47907 USA
Harper, Jason D.
[1
,2
]
Charipar, Nicholas A.
论文数: 0引用数: 0
h-index: 0
机构:
Purdue Univ, Dept Chem, W Lafayette, IN 47907 USA
Purdue Univ, Ctr Analyt Instrumentat Dev, W Lafayette, IN 47907 USAPurdue Univ, Dept Chem, W Lafayette, IN 47907 USA
Charipar, Nicholas A.
[1
,2
]
Ouyang, Zheng
论文数: 0引用数: 0
h-index: 0
机构:
Purdue Univ, Ctr Analyt Instrumentat Dev, W Lafayette, IN 47907 USA
Purdue Univ, Weldon Sch Biomed Engn, W Lafayette, IN 47907 USAPurdue Univ, Dept Chem, W Lafayette, IN 47907 USA
Ouyang, Zheng
[2
,3
]
Cooks, R. Graham
论文数: 0引用数: 0
h-index: 0
机构:
Purdue Univ, Dept Chem, W Lafayette, IN 47907 USA
Purdue Univ, Ctr Analyt Instrumentat Dev, W Lafayette, IN 47907 USAPurdue Univ, Dept Chem, W Lafayette, IN 47907 USA
Cooks, R. Graham
[1
,2
]
机构:
[1] Purdue Univ, Dept Chem, W Lafayette, IN 47907 USA
[2] Purdue Univ, Ctr Analyt Instrumentat Dev, W Lafayette, IN 47907 USA
[3] Purdue Univ, Weldon Sch Biomed Engn, W Lafayette, IN 47907 USA
Low-temperature plasma (LTP) permits direct ambient ionization and mass analysis of samples in their native environment with minimal or no prior preparation. LTP utilizes dielectric barrier discharges (DBDs) to create a low power plasma which is guided by gas flow onto the sample from which analytes are desorbed and ionized. In this study, the potential of LTP-MS for the detection of pesticide residues in food is demonstrated. Thirteen multi-class agricultural chemicals were studied (ametryn, amitraz, atrazine, buprofezin, DEET, diphenylamine, ethoxyquin, imazalil, isofenphosmethyl, isoproturon, malathion, parathion-ethyl and terbuthylazine). To evaluate the potential of the proposed approach, LTP-MS experiments were performed directly on fruit peels as well as on fruit/vegetable extracts. Most of the agrochemicals examined displayed remarkable sensitivity in the positive ion mode, giving limits of detection (LOD) for the direct measurement in the low picogram range. Tandem mass spectrometry (MS/MS) was used to confirm identification of selected pesticides by using for these experiments spiked fruit/vegetable extracts (QuEChERS, a standard sample treatment protocol) at levels as low as 1 pg, absolute, for some of the analytes. Comparisons of the data obtained by direct LTP-MS were made with the slower but more accurate conventional LC-MS/MS procedure. Herbicides spiked in aqueous solutions were detectable at LODs as low as 0.5 mg L(-1) without the need for any sample preparation. The results demonstrate that ambient LTP-MS can be applied for the detection and confirmation of traces of agrochemicals in actual market-purchased produce and in natural water samples. Quantitative analysis was also performed in a few selected cases and displayed a relatively high degree of linearity over four orders of magnitude.
机构:
Sichuan Univ, Coll Chem, Res Ctr Analyt Instrumentat, Chengdu 610064, Peoples R ChinaSichuan Univ, Coll Chem, Res Ctr Analyt Instrumentat, Chengdu 610064, Peoples R China
Wang, Bo
Ding, Xuelu
论文数: 0引用数: 0
h-index: 0
机构:
Sichuan Univ, Coll Chem, Res Ctr Analyt Instrumentat, Chengdu 610064, Peoples R ChinaSichuan Univ, Coll Chem, Res Ctr Analyt Instrumentat, Chengdu 610064, Peoples R China
Ding, Xuelu
Zhao, Zhongjun
论文数: 0引用数: 0
h-index: 0
机构:
Sichuan Univ, Coll Chem, Res Ctr Analyt Instrumentat, Chengdu 610064, Peoples R ChinaSichuan Univ, Coll Chem, Res Ctr Analyt Instrumentat, Chengdu 610064, Peoples R China
Zhao, Zhongjun
Duan, Yixiang
论文数: 0引用数: 0
h-index: 0
机构:
Sichuan Univ, Coll Life Sci, Res Ctr Analyt Instrumentat, Chengdu 610064, Peoples R ChinaSichuan Univ, Coll Chem, Res Ctr Analyt Instrumentat, Chengdu 610064, Peoples R China
机构:
Univ Leipzig, Fac Chem & Mineral, Res Grp Mass Spectrometry, Linnestr 3, D-04103 Leipzig, GermanyUniv Leipzig, Fac Chem & Mineral, Res Grp Mass Spectrometry, Linnestr 3, D-04103 Leipzig, Germany
Kiontke, Andreas
Billig, Susan
论文数: 0引用数: 0
h-index: 0
机构:
Univ Leipzig, Fac Chem & Mineral, Res Grp Mass Spectrometry, Linnestr 3, D-04103 Leipzig, GermanyUniv Leipzig, Fac Chem & Mineral, Res Grp Mass Spectrometry, Linnestr 3, D-04103 Leipzig, Germany
Billig, Susan
Birkemeyer, Claudia
论文数: 0引用数: 0
h-index: 0
机构:
Univ Leipzig, Fac Chem & Mineral, Res Grp Mass Spectrometry, Linnestr 3, D-04103 Leipzig, GermanyUniv Leipzig, Fac Chem & Mineral, Res Grp Mass Spectrometry, Linnestr 3, D-04103 Leipzig, Germany