Screening of agrochemicals in foodstuffs using low-temperature plasma (LTP) ambient ionization mass spectrometry

被引:93
|
作者
Wiley, Joshua S. [1 ,2 ]
Garcia-Reyes, Juan F. [1 ,2 ,4 ]
Harper, Jason D. [1 ,2 ]
Charipar, Nicholas A. [1 ,2 ]
Ouyang, Zheng [2 ,3 ]
Cooks, R. Graham [1 ,2 ]
机构
[1] Purdue Univ, Dept Chem, W Lafayette, IN 47907 USA
[2] Purdue Univ, Ctr Analyt Instrumentat Dev, W Lafayette, IN 47907 USA
[3] Purdue Univ, Weldon Sch Biomed Engn, W Lafayette, IN 47907 USA
[4] Univ Jaen, Analyt Chem Res Grp, Dept Phys & Analyt Chem, Jaen 23071, Spain
关键词
TIME-OF-FLIGHT; DESORPTION-IONIZATION; EMERGING CONTAMINANTS; AGRICULTURAL HEALTH; PESTICIDE EXPOSURE; RESIDUE ANALYSIS; CURRENT ISSUES; ION-SOURCE; FOOD; PHASE;
D O I
10.1039/b919493b
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Low-temperature plasma (LTP) permits direct ambient ionization and mass analysis of samples in their native environment with minimal or no prior preparation. LTP utilizes dielectric barrier discharges (DBDs) to create a low power plasma which is guided by gas flow onto the sample from which analytes are desorbed and ionized. In this study, the potential of LTP-MS for the detection of pesticide residues in food is demonstrated. Thirteen multi-class agricultural chemicals were studied (ametryn, amitraz, atrazine, buprofezin, DEET, diphenylamine, ethoxyquin, imazalil, isofenphosmethyl, isoproturon, malathion, parathion-ethyl and terbuthylazine). To evaluate the potential of the proposed approach, LTP-MS experiments were performed directly on fruit peels as well as on fruit/vegetable extracts. Most of the agrochemicals examined displayed remarkable sensitivity in the positive ion mode, giving limits of detection (LOD) for the direct measurement in the low picogram range. Tandem mass spectrometry (MS/MS) was used to confirm identification of selected pesticides by using for these experiments spiked fruit/vegetable extracts (QuEChERS, a standard sample treatment protocol) at levels as low as 1 pg, absolute, for some of the analytes. Comparisons of the data obtained by direct LTP-MS were made with the slower but more accurate conventional LC-MS/MS procedure. Herbicides spiked in aqueous solutions were detectable at LODs as low as 0.5 mg L(-1) without the need for any sample preparation. The results demonstrate that ambient LTP-MS can be applied for the detection and confirmation of traces of agrochemicals in actual market-purchased produce and in natural water samples. Quantitative analysis was also performed in a few selected cases and displayed a relatively high degree of linearity over four orders of magnitude.
引用
收藏
页码:971 / 979
页数:9
相关论文
共 50 条
  • [21] Peltier Heating-Assisted Low Temperature Plasma Ionization for Ambient Mass Spectrometry
    Lee, Hyoung Jun
    Oh, Ji-Seon
    Heo, Sung Woo
    Moon, Jeong Hee
    Kim, Jeong-Hoon
    Park, Sung Goo
    Park, Byoung Chul
    Kweon, Gi Ryang
    Yim, Yong-Hyeon
    MASS SPECTROMETRY LETTERS, 2015, 6 (03) : 71 - 74
  • [22] Molecularly imprinted polymer (MIP) membrane assisted direct spray ionization mass spectrometry for agrochemicals screening in foodstuffs
    Pereira, Igor
    Rodrigues, Marcella Ferreira
    Chaves, Andrea Rodrigues
    Vaz, Boniek Gontijo
    TALANTA, 2018, 178 : 507 - 514
  • [23] Method development for directly screening pesticide residues in foodstuffs using ambient microfabricated glow discharge plasma (MFGDP) desorption/ionization mass spectrometry
    Wang, Bo
    Ding, Xuelu
    Zhao, Zhongjun
    Duan, Yixiang
    INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 2015, 377 : 507 - 514
  • [24] Low-Temperature Plasma Ionization Ion Mobility Spectrometry
    Jafari, Mohammad T.
    ANALYTICAL CHEMISTRY, 2011, 83 (03) : 797 - 803
  • [25] Response in Ambient Low Temperature Plasma Ionization Compared to Electrospray and Atmospheric Pressure Chemical Ionization for Mass Spectrometry
    Kiontke, Andreas
    Billig, Susan
    Birkemeyer, Claudia
    INTERNATIONAL JOURNAL OF ANALYTICAL CHEMISTRY, 2018, 2018
  • [26] Development of an inverse low-temperature plasma ionization source for liquid chromatography/mass spectrometry
    Brecht, Dominik
    Uteschil, Florian
    Schmitz, Oliver J.
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2021, 35 (10)
  • [27] Effect of Ultrasonic Microdroplet Generation in the Low-Temperature Plasma Ionization-Mass Spectrometry
    Lee, Hyoung Jun
    Yim, Yong-Hyeon
    MASS SPECTROMETRY LETTERS, 2019, 10 (04) : 103 - 107
  • [28] Low-Temperature Plasma Ionization Differential Ion Mobility Spectrometry
    Kuklya, Andriy
    Engelhard, Carsten
    Uteschil, Florian
    Kerpen, Klaus
    Marks, Robert
    Telgheder, Ursula
    ANALYTICAL CHEMISTRY, 2015, 87 (17) : 8932 - 8940
  • [29] Rapid screening of active ingredients in drugs by mass spectrometry with low-temperature plasma probe
    Yueying Liu
    Ziqing Lin
    Sichun Zhang
    Chengdui Yang
    Xinrong Zhang
    Analytical and Bioanalytical Chemistry, 2009, 395 : 591 - 599
  • [30] Rapid screening of active ingredients in drugs by mass spectrometry with low-temperature plasma probe
    Liu, Yueying
    Lin, Ziqing
    Zhang, Sichun
    Yang, Chengdui
    Zhang, Xinrong
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2009, 395 (03) : 591 - 599