Low-Temperature Plasma Ionization Differential Ion Mobility Spectrometry

被引:20
|
作者
Kuklya, Andriy [1 ]
Engelhard, Carsten [2 ]
Uteschil, Florian [1 ]
Kerpen, Klaus [1 ]
Marks, Robert [1 ]
Telgheder, Ursula [1 ,3 ]
机构
[1] UDE, Dept Instrumental Analyt Chem, D-45141 Essen, Germany
[2] Univ Siegen, Dept Biol & Chem, D-57068 Siegen, Germany
[3] IWW Water Ctr, D-45476 Mulheim, Germany
关键词
DESORPTION/IONIZATION MASS-SPECTROMETRY; ATMOSPHERIC-PRESSURE; PROBE; OPTIMIZATION; FIELD;
D O I
10.1021/acs.analchem.5b02077
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A low-temperature plasma (LTP) was used as an ionization source for differential ion mobility spectrometry (DMS) for the first time. This ionization source enhances the potential of DMS as a miniaturized System for on-site rapid monitoring. The effects of experimental parameters (e.g., discharge/carrier gas composition and flow rate, applied voltage) on the analysis of model aromatic compounds were investigated and discussed. It was found that the nature of reactant ion positive (RIP) is dependent on the discharge/carrier gas composition. The best response to the analyte was achieved when pure nitrogen was used as the discharge/carrier gas. The ability to perform analysis with zero helium consumption is especially attractive in view of the potential application of LTP-DMS for online (and on-site) monitoring. Analytical performance was determined with six environmentally relevant model compounds (benzene, toluene, ethylbenzene, p-xylene, 1,2,4-trimethylbenzene, and naphthalene) using LTP and directly compared to APPI and APCI (Ni-63) ionization sources. When LTP was coupled to DMS, calculated LOD values were found to be in the range of 35-257 ng L-1 (concentration in the carrier gas). These values are competitive with those calculated for two DMS equipped with traditional ionization sources (APPI, Ni-63). The obtained results are promising enough to ensure the potential of LTP as ionization source for DMS.
引用
收藏
页码:8932 / 8940
页数:9
相关论文
共 50 条
  • [1] Low-Temperature Plasma Ionization Ion Mobility Spectrometry
    Jafari, Mohammad T.
    ANALYTICAL CHEMISTRY, 2011, 83 (03) : 797 - 803
  • [2] Analysis of liquid samples by Low-Temperature Plasma Ionization Source-ion mobility spectrometry
    Ismaili, Hashem
    Jafari, Mohammad. T.
    Khayamian, Taghi
    INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 2023, 483
  • [3] Arrays of low-temperature plasma probes for ambient ionization mass spectrometry
    Dalgleish, Jon K.
    Wleklinski, Michael
    Shelley, Jacob T.
    Mulligan, Christopher C.
    Ouyang, Zheng
    Cooks, R. Graham
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2013, 27 (01) : 135 - 142
  • [4] The requirements for low-temperature plasma ionization support miniaturization of the ion source
    Kiontke, Andreas
    Holzer, Frank
    Belder, Detlev
    Birkemeyer, Claudia
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2018, 410 (16) : 3715 - 3722
  • [5] The requirements for low-temperature plasma ionization support miniaturization of the ion source
    Andreas Kiontke
    Frank Holzer
    Detlev Belder
    Claudia Birkemeyer
    Analytical and Bioanalytical Chemistry, 2018, 410 : 3715 - 3722
  • [6] IONIZATION WAVES IN LOW-TEMPERATURE PLASMA
    LANDA, PS
    MISKINOVA, NA
    PONOMAREV, YV
    USPEKHI FIZICHESKIKH NAUK, 1980, 132 (04): : 601 - 637
  • [7] X-ray ionization differential ion mobility spectrometry
    Kuklya, Andriy
    Reinecke, Tobias
    Uteschil, Florian
    Kerpen, Klaus
    Zimmermann, Stefan
    Telgheder, Ursula
    TALANTA, 2017, 162 : 159 - 166
  • [8] IONIZATION WAVES EXCITATION IN LOW-TEMPERATURE PLASMA
    LANDA, PS
    PONOMAREV, YV
    RADIOTEKHNIKA I ELEKTRONIKA, 1976, 21 (11): : 2337 - 2343
  • [9] ON THEORY OF IONIZATION AND RECOMBINATION IN A LOW-TEMPERATURE PLASMA
    BIBERMAN, LM
    VOROBEV, VS
    YAKUBOV, IT
    SOVIET PHYSICS JETP-USSR, 1969, 29 (06): : 1070 - +
  • [10] STATE OF LOW-TEMPERATURE PLASMA WITH A NONEQUILIBRIUM IONIZATION
    BIBERMAN, LM
    VOROBYEV, VS
    YAKUBOV, IT
    USPEKHI FIZICHESKIKH NAUK, 1979, 128 (02): : 233 - 271