Low-Temperature Plasma Ionization Differential Ion Mobility Spectrometry

被引:20
|
作者
Kuklya, Andriy [1 ]
Engelhard, Carsten [2 ]
Uteschil, Florian [1 ]
Kerpen, Klaus [1 ]
Marks, Robert [1 ]
Telgheder, Ursula [1 ,3 ]
机构
[1] UDE, Dept Instrumental Analyt Chem, D-45141 Essen, Germany
[2] Univ Siegen, Dept Biol & Chem, D-57068 Siegen, Germany
[3] IWW Water Ctr, D-45476 Mulheim, Germany
关键词
DESORPTION/IONIZATION MASS-SPECTROMETRY; ATMOSPHERIC-PRESSURE; PROBE; OPTIMIZATION; FIELD;
D O I
10.1021/acs.analchem.5b02077
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A low-temperature plasma (LTP) was used as an ionization source for differential ion mobility spectrometry (DMS) for the first time. This ionization source enhances the potential of DMS as a miniaturized System for on-site rapid monitoring. The effects of experimental parameters (e.g., discharge/carrier gas composition and flow rate, applied voltage) on the analysis of model aromatic compounds were investigated and discussed. It was found that the nature of reactant ion positive (RIP) is dependent on the discharge/carrier gas composition. The best response to the analyte was achieved when pure nitrogen was used as the discharge/carrier gas. The ability to perform analysis with zero helium consumption is especially attractive in view of the potential application of LTP-DMS for online (and on-site) monitoring. Analytical performance was determined with six environmentally relevant model compounds (benzene, toluene, ethylbenzene, p-xylene, 1,2,4-trimethylbenzene, and naphthalene) using LTP and directly compared to APPI and APCI (Ni-63) ionization sources. When LTP was coupled to DMS, calculated LOD values were found to be in the range of 35-257 ng L-1 (concentration in the carrier gas). These values are competitive with those calculated for two DMS equipped with traditional ionization sources (APPI, Ni-63). The obtained results are promising enough to ensure the potential of LTP as ionization source for DMS.
引用
收藏
页码:8932 / 8940
页数:9
相关论文
共 50 条
  • [21] Screening of agrochemicals in foodstuffs using low-temperature plasma (LTP) ambient ionization mass spectrometry
    Wiley, Joshua S.
    Garcia-Reyes, Juan F.
    Harper, Jason D.
    Charipar, Nicholas A.
    Ouyang, Zheng
    Cooks, R. Graham
    ANALYST, 2010, 135 (05) : 971 - 979
  • [22] Direct olive oil analysis by low-temperature plasma (LTP) ambient ionization mass spectrometry
    Garcia-Reyes, Juan F.
    Mazzoti, Fabio
    Harper, Jason D.
    Charipar, Nicholas A.
    Oradu, Sheran
    Ouyang, Zheng
    Sindona, Giovanni
    Cooks, R. Graham
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2009, 23 (19) : 3057 - 3062
  • [23] Chemometric optimization of a low-temperature plasma source design for ambient desorption/ionization mass spectrometry
    Albert, Anastasia
    Engelhard, Carsten
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2015, 105 : 109 - 115
  • [24] Surface ionization ion mobility spectrometry
    Anal Chem, 1 (273-278):
  • [25] Surface ionization ion mobility spectrometry
    Wu, C
    Hill, HH
    Rasulev, UK
    Nazarov, EG
    ANALYTICAL CHEMISTRY, 1999, 71 (01) : 273 - 278
  • [26] COMPUTATION OF IONIZATION INSTABILITY IN MAGNETIZED LOW-TEMPERATURE PLASMA
    VELIKHOV, EP
    DEGTYARE.LM
    SAMARSKI.AA
    FAVORSKI.AP
    DOKLADY AKADEMII NAUK SSSR, 1969, 184 (03): : 578 - &
  • [27] Low-Temperature Plasma Probe for Ambient Desorption Ionization
    Harper, Jason D.
    Charipar, Nicholas A.
    Mulligan, Christopher C.
    Zhang, Xinrong
    Cooks, R. Graham
    Ouyang, Zheng
    ANALYTICAL CHEMISTRY, 2008, 80 (23) : 9097 - 9104
  • [28] THRESHOLD OF IONIZATION INSTABILITY IN AN UNBOUNDED LOW-TEMPERATURE PLASMA
    ZAMPAGLIONE, V
    PLASMA PHYSICS, 1972, 14 (06): : 664 - +
  • [29] Differential Ion Mobility Spectrometry
    Baumbach, Joerg Ingo
    INTERNATIONAL JOURNAL FOR ION MOBILITY SPECTROMETRY, 2010, 13 (3-4) : 167 - 168
  • [30] LOW-TEMPERATURE ION MOBILITY IN INTERACTING FERMI LIQUIDS
    GOULD, H
    MA, SK
    PHYSICAL REVIEW, 1969, 183 (01): : 338 - &