Screening of agrochemicals in foodstuffs using low-temperature plasma (LTP) ambient ionization mass spectrometry

被引:93
|
作者
Wiley, Joshua S. [1 ,2 ]
Garcia-Reyes, Juan F. [1 ,2 ,4 ]
Harper, Jason D. [1 ,2 ]
Charipar, Nicholas A. [1 ,2 ]
Ouyang, Zheng [2 ,3 ]
Cooks, R. Graham [1 ,2 ]
机构
[1] Purdue Univ, Dept Chem, W Lafayette, IN 47907 USA
[2] Purdue Univ, Ctr Analyt Instrumentat Dev, W Lafayette, IN 47907 USA
[3] Purdue Univ, Weldon Sch Biomed Engn, W Lafayette, IN 47907 USA
[4] Univ Jaen, Analyt Chem Res Grp, Dept Phys & Analyt Chem, Jaen 23071, Spain
关键词
TIME-OF-FLIGHT; DESORPTION-IONIZATION; EMERGING CONTAMINANTS; AGRICULTURAL HEALTH; PESTICIDE EXPOSURE; RESIDUE ANALYSIS; CURRENT ISSUES; ION-SOURCE; FOOD; PHASE;
D O I
10.1039/b919493b
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Low-temperature plasma (LTP) permits direct ambient ionization and mass analysis of samples in their native environment with minimal or no prior preparation. LTP utilizes dielectric barrier discharges (DBDs) to create a low power plasma which is guided by gas flow onto the sample from which analytes are desorbed and ionized. In this study, the potential of LTP-MS for the detection of pesticide residues in food is demonstrated. Thirteen multi-class agricultural chemicals were studied (ametryn, amitraz, atrazine, buprofezin, DEET, diphenylamine, ethoxyquin, imazalil, isofenphosmethyl, isoproturon, malathion, parathion-ethyl and terbuthylazine). To evaluate the potential of the proposed approach, LTP-MS experiments were performed directly on fruit peels as well as on fruit/vegetable extracts. Most of the agrochemicals examined displayed remarkable sensitivity in the positive ion mode, giving limits of detection (LOD) for the direct measurement in the low picogram range. Tandem mass spectrometry (MS/MS) was used to confirm identification of selected pesticides by using for these experiments spiked fruit/vegetable extracts (QuEChERS, a standard sample treatment protocol) at levels as low as 1 pg, absolute, for some of the analytes. Comparisons of the data obtained by direct LTP-MS were made with the slower but more accurate conventional LC-MS/MS procedure. Herbicides spiked in aqueous solutions were detectable at LODs as low as 0.5 mg L(-1) without the need for any sample preparation. The results demonstrate that ambient LTP-MS can be applied for the detection and confirmation of traces of agrochemicals in actual market-purchased produce and in natural water samples. Quantitative analysis was also performed in a few selected cases and displayed a relatively high degree of linearity over four orders of magnitude.
引用
收藏
页码:971 / 979
页数:9
相关论文
共 50 条
  • [1] Direct olive oil analysis by low-temperature plasma (LTP) ambient ionization mass spectrometry
    Garcia-Reyes, Juan F.
    Mazzoti, Fabio
    Harper, Jason D.
    Charipar, Nicholas A.
    Oradu, Sheran
    Ouyang, Zheng
    Sindona, Giovanni
    Cooks, R. Graham
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2009, 23 (19) : 3057 - 3062
  • [2] Rapid determination of multiclass fungicides in wine by low-temperature plasma (LTP) ambient ionization mass spectrometry
    Beneito-Cambra, Miriam
    Perez-Ortega, Patricia
    Molina-Diaz, Antonio
    Garcia-Reyes, Juan F.
    ANALYTICAL METHODS, 2015, 7 (17) : 7345 - 7351
  • [3] Arrays of low-temperature plasma probes for ambient ionization mass spectrometry
    Dalgleish, Jon K.
    Wleklinski, Michael
    Shelley, Jacob T.
    Mulligan, Christopher C.
    Ouyang, Zheng
    Cooks, R. Graham
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2013, 27 (01) : 135 - 142
  • [4] Characterization of a Low-Temperature Plasma (LTP) Ambient Ionization Source Using Temporally Resolved Monochromatic Imaging Spectrometry
    Chan, George C. -Y.
    Engelhard, Carsten
    Wiley, Joshua S.
    Shoulds, Ayanna U.
    Cooks, R. Graham
    Hieftje, Gary M.
    Shelley, Jacob T.
    APPLIED SPECTROSCOPY, 2023, 77 (08) : 940 - 956
  • [5] Spray-inlet microwave plasma torch and low temperature plasma ionization for ambient mass spectrometry of agrochemicals
    Wang, Yaliang
    Xu, Li
    Zhu, Hui
    Dong, Junguo
    Cheng, Ping
    Zhou, Zhen
    ANALYTICAL METHODS, 2019, 11 (42) : 5421 - 5430
  • [6] Ambient ion/molecule reactions in low-temperature plasmas (LTP): reactive LTP mass spectrometry
    Benassi, Mario
    Garcia-Reyes, Juan F.
    Spengler, Bernhard
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2013, 27 (07) : 795 - 804
  • [7] Detection of Explosives and Related Compounds by Low-Temperature Plasma Ambient Ionization Mass Spectrometry
    Garcia-Reyes, Juan F.
    Harper, Jason D.
    Salazar, Gary A.
    Charipar, Nicholas A.
    Ouyang, Zheng
    Cooks, R. Graham
    ANALYTICAL CHEMISTRY, 2011, 83 (03) : 1084 - 1092
  • [8] Direct olive oil analysis by low-temperature plasma (LTP) ambient ionization mass spectrometry (vol 23, pg 3057, 2009)
    Garcia-Reyes, Juan F.
    Mazzotti, Fabio
    Harper, Jason D.
    Charipar, Nicholas A.
    Oradu, Sheran
    Ouyang, Zheng
    Sindona, Giovanni
    Cooks, R. Graham
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2009, 23 (21) : 3492 - 3492
  • [9] Rapid screening of antimalarial drugs using low-temperature plasma desorption/ionization Orbitrap mass spectrometry
    Ateacha, Derick N.
    Kuhlmann, Christopher
    Engelhard, Carsten
    ANALYTICAL METHODS, 2019, 11 (05) : 566 - 574
  • [10] Analyte and matrix evaporability - key players of low-temperature plasma ionization for ambient mass spectrometry
    Kiontke, Andreas
    Engel, Christoph
    Belder, Detlev
    Birkemeyer, Claudia
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2018, 410 (21) : 5123 - 5130