Screening of agrochemicals in foodstuffs using low-temperature plasma (LTP) ambient ionization mass spectrometry

被引:93
|
作者
Wiley, Joshua S. [1 ,2 ]
Garcia-Reyes, Juan F. [1 ,2 ,4 ]
Harper, Jason D. [1 ,2 ]
Charipar, Nicholas A. [1 ,2 ]
Ouyang, Zheng [2 ,3 ]
Cooks, R. Graham [1 ,2 ]
机构
[1] Purdue Univ, Dept Chem, W Lafayette, IN 47907 USA
[2] Purdue Univ, Ctr Analyt Instrumentat Dev, W Lafayette, IN 47907 USA
[3] Purdue Univ, Weldon Sch Biomed Engn, W Lafayette, IN 47907 USA
[4] Univ Jaen, Analyt Chem Res Grp, Dept Phys & Analyt Chem, Jaen 23071, Spain
关键词
TIME-OF-FLIGHT; DESORPTION-IONIZATION; EMERGING CONTAMINANTS; AGRICULTURAL HEALTH; PESTICIDE EXPOSURE; RESIDUE ANALYSIS; CURRENT ISSUES; ION-SOURCE; FOOD; PHASE;
D O I
10.1039/b919493b
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Low-temperature plasma (LTP) permits direct ambient ionization and mass analysis of samples in their native environment with minimal or no prior preparation. LTP utilizes dielectric barrier discharges (DBDs) to create a low power plasma which is guided by gas flow onto the sample from which analytes are desorbed and ionized. In this study, the potential of LTP-MS for the detection of pesticide residues in food is demonstrated. Thirteen multi-class agricultural chemicals were studied (ametryn, amitraz, atrazine, buprofezin, DEET, diphenylamine, ethoxyquin, imazalil, isofenphosmethyl, isoproturon, malathion, parathion-ethyl and terbuthylazine). To evaluate the potential of the proposed approach, LTP-MS experiments were performed directly on fruit peels as well as on fruit/vegetable extracts. Most of the agrochemicals examined displayed remarkable sensitivity in the positive ion mode, giving limits of detection (LOD) for the direct measurement in the low picogram range. Tandem mass spectrometry (MS/MS) was used to confirm identification of selected pesticides by using for these experiments spiked fruit/vegetable extracts (QuEChERS, a standard sample treatment protocol) at levels as low as 1 pg, absolute, for some of the analytes. Comparisons of the data obtained by direct LTP-MS were made with the slower but more accurate conventional LC-MS/MS procedure. Herbicides spiked in aqueous solutions were detectable at LODs as low as 0.5 mg L(-1) without the need for any sample preparation. The results demonstrate that ambient LTP-MS can be applied for the detection and confirmation of traces of agrochemicals in actual market-purchased produce and in natural water samples. Quantitative analysis was also performed in a few selected cases and displayed a relatively high degree of linearity over four orders of magnitude.
引用
收藏
页码:971 / 979
页数:9
相关论文
共 50 条
  • [41] Miniature Flow-Through Low-Temperature Plasma Ionization Source for Ambient Ionization of Gases and Aerosols
    Spencer, Sandra E.
    Santiago, Brandon G.
    Glish, Gary L.
    ANALYTICAL CHEMISTRY, 2015, 87 (23) : 11887 - 11892
  • [42] The Application of the Microwave Plasma Ionization Source in Ambient Mass Spectrometry
    Maria Guć
    Edward Reszke
    Michał Cegłowski
    Grzegorz Schroeder
    Plasma Chemistry and Plasma Processing, 2019, 39 : 1001 - 1017
  • [43] The Application of the Microwave Plasma Ionization Source in Ambient Mass Spectrometry
    Guc, Maria
    Reszke, Edward
    Ceglowski, Michal
    Schroeder, Grzegorz
    PLASMA CHEMISTRY AND PLASMA PROCESSING, 2019, 39 (04) : 1001 - 1017
  • [44] Mass Spectrometry Study on Ions Generated by Low-Temperature Plasma Jet
    Chen, Baihan
    Liu, Dawei
    IEEE TRANSACTIONS ON PLASMA SCIENCE, 2021, 49 (03) : 1190 - 1194
  • [45] Temperature-Tuning Desorption Ionization for Ambient Mass Spectrometry
    Li, Ningxi
    Cai, Zhijun
    Zhang, Zhongyao
    Zhang, Wenpeng
    Ma, Xiaoxiao
    Zhou, Xiaoyu
    Ouyang, Zheng
    ANALYTICAL CHEMISTRY, 2023, 95 (29) : 11099 - 11105
  • [46] Gas Chromatography Interfaced with Atmospheric Pressure Ionization-Quadrupole Time-of-Flight-Mass Spectrometry by Low-Temperature Plasma Ionization
    Norgaard, Asger W.
    Kofoed-Sorensen, Vivi
    Svensmark, Bo
    Wolkoff, Peder
    Clausen, Per Axel
    ANALYTICAL CHEMISTRY, 2013, 85 (01) : 28 - 32
  • [47] Development of a graphite low-temperature plasma source with dual-mode in-source fragmentation for ambient mass spectrometry
    Almasian, Mohammad Reza
    Yang, Chengdui
    Xing, Zhi
    Zhang, Sichun
    Zhang, Xinrong
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2010, 24 (06) : 742 - 748
  • [48] Rapid Screening of Methamphetamine in Hair by Ambient Ionization Mass Spectrometry (AIMS)
    Shi, Shengyang
    Wen, Luhong
    Hu, Shundi
    Chen, La
    Qiao, Juanjuan
    Hong, Huanhuan
    ANALYTICAL LETTERS, 2023, 56 (16) : 2541 - 2553
  • [49] Low-Temperature Plasma Pretreatment Enhanced Cholesterol Detection in Brain by Desorption Electrospray Ionization-Mass Spectrometry Imaging
    Rahman, Md. Muedur
    Islam, Ariful
    Al Mamun, Md.
    Afroz, Mst. Sayela
    Nabi, Md. Mahamodun
    Sakamoto, Takumi
    Sato, Tomohito
    Kahyo, Tomoaki
    Takahashi, Yutaka
    Okino, Akitoshi
    Setou, Mitsutoshi
    JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2024, 35 (06) : 1227 - 1236
  • [50] Rapid and quantitative analysis of pesticides in fruits by QuEChERS pretreatment and low-temperature plasma desorption/ionization orbitrap mass spectrometry
    Albert, Anastasia
    Kramer, Andrea
    Scheeren, Simon
    Engelhard, Carsten
    ANALYTICAL METHODS, 2014, 6 (15) : 5463 - 5471