Rapid determination of multiclass fungicides in wine by low-temperature plasma (LTP) ambient ionization mass spectrometry

被引:0
|
作者
Beneito-Cambra, Miriam [1 ]
Perez-Ortega, Patricia [1 ]
Molina-Diaz, Antonio [1 ]
Garcia-Reyes, Juan F. [1 ]
机构
[1] Univ Jaen, Dept Phys & Analyt Chem, Analyt Chem Res Grp FQM 323, Jaen 23071, Spain
关键词
PRESSURE DESORPTION IONIZATION; ELECTROSPRAY-IONIZATION; OPEN-AIR; PESTICIDES;
D O I
10.1039/c5ay00810g
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A low-temperature plasma (LTP) probe is a plasma-based technique that permits the direct and rapid ambient ionization and mass analysis of relatively complex samples in their native environment. It belongs to the ambient desorption/ionization mass spectrometry (MS) technique, and these features map well against the requirements of food quality and safety testing. In this study, the application of LTP-MS for the rapid screening and detection of pesticides in wines has been evaluated. Aliquots of a sample extract (3 mu L of each solution) were deposited on a heated (120 degrees C) microscope glass slide for LTP-MS analysis. The analytical performance of LTP-MS has been studied for a set of 10 multiclass fungicides selected according to their relevance and presence in actual wine samples. The compounds included in the study were azoxystrobin, carbendazim, dimethomorph, fenhexamid, flusilazol, metalaxyl, penconazole, tebuconazole, imazalil and thiabendazole. Two different approaches were examined: (i) the direct analyses of wines with no prior treatment besides a simple sample dilution, and (ii) the analyses of sample extracts obtained after a thorough sample preparation step using solid-phase extraction with polymeric cartridges. The proposed approach enabled the detection of the pesticides in wine at low concentration levels in the range from 15 mu g L-1 to 300 mu g L-1 (fulfilling maximum residue levels (MRLs) set in EU regulations in all cases) by means of tandem mass spectrometry experiments with an ion trap operated in the positive ionization mode. The qualitative results obtained with actual red wine market samples compared well against the reference method based on liquid chromatography/mass spectrometry. Various examples shown demonstrate that ambient LTP-MS can be applied for the detection of these chemicals in beverages without sample treatment steps besides dilution.
引用
收藏
页码:7345 / 7351
页数:7
相关论文
共 50 条
  • [1] Screening of agrochemicals in foodstuffs using low-temperature plasma (LTP) ambient ionization mass spectrometry
    Wiley, Joshua S.
    Garcia-Reyes, Juan F.
    Harper, Jason D.
    Charipar, Nicholas A.
    Ouyang, Zheng
    Cooks, R. Graham
    ANALYST, 2010, 135 (05) : 971 - 979
  • [2] Direct olive oil analysis by low-temperature plasma (LTP) ambient ionization mass spectrometry
    Garcia-Reyes, Juan F.
    Mazzoti, Fabio
    Harper, Jason D.
    Charipar, Nicholas A.
    Oradu, Sheran
    Ouyang, Zheng
    Sindona, Giovanni
    Cooks, R. Graham
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2009, 23 (19) : 3057 - 3062
  • [3] Arrays of low-temperature plasma probes for ambient ionization mass spectrometry
    Dalgleish, Jon K.
    Wleklinski, Michael
    Shelley, Jacob T.
    Mulligan, Christopher C.
    Ouyang, Zheng
    Cooks, R. Graham
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2013, 27 (01) : 135 - 142
  • [4] Fast quantitation of pyrazole fungicides in wine by ambient ionization mass spectrometry
    Pu, Fan
    Zhang, Wenpeng
    Han, Chao
    Ouyang, Zheng
    ANALYTICAL METHODS, 2017, 9 (34) : 5058 - 5064
  • [5] Ambient ion/molecule reactions in low-temperature plasmas (LTP): reactive LTP mass spectrometry
    Benassi, Mario
    Garcia-Reyes, Juan F.
    Spengler, Bernhard
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2013, 27 (07) : 795 - 804
  • [6] Detection of Explosives and Related Compounds by Low-Temperature Plasma Ambient Ionization Mass Spectrometry
    Garcia-Reyes, Juan F.
    Harper, Jason D.
    Salazar, Gary A.
    Charipar, Nicholas A.
    Ouyang, Zheng
    Cooks, R. Graham
    ANALYTICAL CHEMISTRY, 2011, 83 (03) : 1084 - 1092
  • [7] Direct olive oil analysis by low-temperature plasma (LTP) ambient ionization mass spectrometry (vol 23, pg 3057, 2009)
    Garcia-Reyes, Juan F.
    Mazzotti, Fabio
    Harper, Jason D.
    Charipar, Nicholas A.
    Oradu, Sheran
    Ouyang, Zheng
    Sindona, Giovanni
    Cooks, R. Graham
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2009, 23 (21) : 3492 - 3492
  • [8] Characterization of a Low-Temperature Plasma (LTP) Ambient Ionization Source Using Temporally Resolved Monochromatic Imaging Spectrometry
    Chan, George C. -Y.
    Engelhard, Carsten
    Wiley, Joshua S.
    Shoulds, Ayanna U.
    Cooks, R. Graham
    Hieftje, Gary M.
    Shelley, Jacob T.
    APPLIED SPECTROSCOPY, 2023, 77 (08) : 940 - 956
  • [9] Direct detection of fatty acid ethyl esters using low temperature plasma (LTP) ambient ionization mass spectrometry for rapid bacterial differentiation
    Zhang, J. Isabella
    Costa, Anthony B.
    Tao, W. Andy
    Cooks, R. Graham
    ANALYST, 2011, 136 (15) : 3091 - 3097
  • [10] Analyte and matrix evaporability - key players of low-temperature plasma ionization for ambient mass spectrometry
    Kiontke, Andreas
    Engel, Christoph
    Belder, Detlev
    Birkemeyer, Claudia
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2018, 410 (21) : 5123 - 5130