Rapid determination of multiclass fungicides in wine by low-temperature plasma (LTP) ambient ionization mass spectrometry

被引:0
|
作者
Beneito-Cambra, Miriam [1 ]
Perez-Ortega, Patricia [1 ]
Molina-Diaz, Antonio [1 ]
Garcia-Reyes, Juan F. [1 ]
机构
[1] Univ Jaen, Dept Phys & Analyt Chem, Analyt Chem Res Grp FQM 323, Jaen 23071, Spain
关键词
PRESSURE DESORPTION IONIZATION; ELECTROSPRAY-IONIZATION; OPEN-AIR; PESTICIDES;
D O I
10.1039/c5ay00810g
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A low-temperature plasma (LTP) probe is a plasma-based technique that permits the direct and rapid ambient ionization and mass analysis of relatively complex samples in their native environment. It belongs to the ambient desorption/ionization mass spectrometry (MS) technique, and these features map well against the requirements of food quality and safety testing. In this study, the application of LTP-MS for the rapid screening and detection of pesticides in wines has been evaluated. Aliquots of a sample extract (3 mu L of each solution) were deposited on a heated (120 degrees C) microscope glass slide for LTP-MS analysis. The analytical performance of LTP-MS has been studied for a set of 10 multiclass fungicides selected according to their relevance and presence in actual wine samples. The compounds included in the study were azoxystrobin, carbendazim, dimethomorph, fenhexamid, flusilazol, metalaxyl, penconazole, tebuconazole, imazalil and thiabendazole. Two different approaches were examined: (i) the direct analyses of wines with no prior treatment besides a simple sample dilution, and (ii) the analyses of sample extracts obtained after a thorough sample preparation step using solid-phase extraction with polymeric cartridges. The proposed approach enabled the detection of the pesticides in wine at low concentration levels in the range from 15 mu g L-1 to 300 mu g L-1 (fulfilling maximum residue levels (MRLs) set in EU regulations in all cases) by means of tandem mass spectrometry experiments with an ion trap operated in the positive ionization mode. The qualitative results obtained with actual red wine market samples compared well against the reference method based on liquid chromatography/mass spectrometry. Various examples shown demonstrate that ambient LTP-MS can be applied for the detection of these chemicals in beverages without sample treatment steps besides dilution.
引用
收藏
页码:7345 / 7351
页数:7
相关论文
共 50 条
  • [31] Fast screening of analytes for chemical reactions by reactive low-temperature plasma ionization mass spectrometry
    Zhang, Wei
    Huang, Guangming
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2015, 29 (21) : 1947 - 1953
  • [32] Low-Temperature Plasma Ionization-Mass Spectrometry for the Analysis of Compounds in Organic Aerosol Particles
    Spencer, Sandra E.
    Tyler, Chelsea A.
    Tolocka, Michael P.
    Glish, Gary L.
    ANALYTICAL CHEMISTRY, 2015, 87 (04) : 2249 - 2254
  • [33] Surface acoustic wave nebulization improves compound selectivity of low-temperature plasma ionization for mass spectrometry
    Kiontke, Andreas
    Roudini, Mehrzad
    Billig, Susan
    Fakhfouri, Amarghan
    Winkler, Andreas
    Birkemeyer, Claudia
    SCIENTIFIC REPORTS, 2021, 11 (01)
  • [34] Thermal Desorption Low Temperature Plasma Ionization Mass Spectrometry for Rapid and Sensitive Detection of Pesticides in Broomcorn
    Wang Shuang
    Wang Zhe
    Hou Ke-Yong
    Li Hai-Yang
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2017, 45 (02) : 175 - 181
  • [35] Mass spectrometry of clustered flows during gas ionization by low-temperature plasma in the diffuser part of the nozzle
    Khudozhitkov, V. E.
    Zarvin, A. E.
    Kalyada, V. V.
    PHYSICS OF PLASMAS, 2025, 32 (03)
  • [36] Chemical analysis and chemical imaging of fragrances and volatile compounds by low-temperature plasma ionization mass spectrometry
    Campbell, Dahlia I.
    Dalgleish, Jon K.
    Cotte-Rodriguez, Ismael
    Maeno, Shuji
    Cooks, R. Graham
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2013, 27 (16) : 1828 - 1836
  • [37] Monitoring rapid reactions with ambient pressure ionization mass spectrometry
    Jansson, Erik
    Zare, Richard
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2017, 253
  • [38] Rapid detection of furanyl fentanyl in complex matrices using Leidenfrost desorption-assisted low-temperature arc plasma ionization mass spectrometry
    Zhang, Wei
    Han, Zhongbao
    Zhao, Zhongyu
    Shi, Jianjun
    Liu, Liyan
    Wang, Dan
    Yu, Zhan
    ANALYST, 2024, 149 (09) : 2762 - 2768
  • [39] Low-temperature plasma (LTP) jets for mass spectrometry (MS): Ion processes, instrumental set-ups, and application examples
    Martinez-Jarquin, Sandra
    Winkler, Robert
    TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2017, 89 : 133 - 145
  • [40] IONIZATION WAVES IN LOW-TEMPERATURE PLASMA
    LANDA, PS
    MISKINOVA, NA
    PONOMAREV, YV
    USPEKHI FIZICHESKIKH NAUK, 1980, 132 (04): : 601 - 637