Rapid determination of multiclass fungicides in wine by low-temperature plasma (LTP) ambient ionization mass spectrometry

被引:0
|
作者
Beneito-Cambra, Miriam [1 ]
Perez-Ortega, Patricia [1 ]
Molina-Diaz, Antonio [1 ]
Garcia-Reyes, Juan F. [1 ]
机构
[1] Univ Jaen, Dept Phys & Analyt Chem, Analyt Chem Res Grp FQM 323, Jaen 23071, Spain
关键词
PRESSURE DESORPTION IONIZATION; ELECTROSPRAY-IONIZATION; OPEN-AIR; PESTICIDES;
D O I
10.1039/c5ay00810g
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A low-temperature plasma (LTP) probe is a plasma-based technique that permits the direct and rapid ambient ionization and mass analysis of relatively complex samples in their native environment. It belongs to the ambient desorption/ionization mass spectrometry (MS) technique, and these features map well against the requirements of food quality and safety testing. In this study, the application of LTP-MS for the rapid screening and detection of pesticides in wines has been evaluated. Aliquots of a sample extract (3 mu L of each solution) were deposited on a heated (120 degrees C) microscope glass slide for LTP-MS analysis. The analytical performance of LTP-MS has been studied for a set of 10 multiclass fungicides selected according to their relevance and presence in actual wine samples. The compounds included in the study were azoxystrobin, carbendazim, dimethomorph, fenhexamid, flusilazol, metalaxyl, penconazole, tebuconazole, imazalil and thiabendazole. Two different approaches were examined: (i) the direct analyses of wines with no prior treatment besides a simple sample dilution, and (ii) the analyses of sample extracts obtained after a thorough sample preparation step using solid-phase extraction with polymeric cartridges. The proposed approach enabled the detection of the pesticides in wine at low concentration levels in the range from 15 mu g L-1 to 300 mu g L-1 (fulfilling maximum residue levels (MRLs) set in EU regulations in all cases) by means of tandem mass spectrometry experiments with an ion trap operated in the positive ionization mode. The qualitative results obtained with actual red wine market samples compared well against the reference method based on liquid chromatography/mass spectrometry. Various examples shown demonstrate that ambient LTP-MS can be applied for the detection of these chemicals in beverages without sample treatment steps besides dilution.
引用
收藏
页码:7345 / 7351
页数:7
相关论文
共 50 条
  • [21] Rapid Characterization of Lithium Ion Battery Electrolytes and Thermal Aging Products by Low-Temperature Plasma Ambient Ionization High-Resolution Mass Spectrometry
    Vortmann, Britta
    Nowak, Sascha
    Engelhard, Carsten
    ANALYTICAL CHEMISTRY, 2013, 85 (06) : 3433 - 3438
  • [22] Low-Temperature Plasma Ionization Ion Mobility Spectrometry
    Jafari, Mohammad T.
    ANALYTICAL CHEMISTRY, 2011, 83 (03) : 797 - 803
  • [23] Response in Ambient Low Temperature Plasma Ionization Compared to Electrospray and Atmospheric Pressure Chemical Ionization for Mass Spectrometry
    Kiontke, Andreas
    Billig, Susan
    Birkemeyer, Claudia
    INTERNATIONAL JOURNAL OF ANALYTICAL CHEMISTRY, 2018, 2018
  • [24] Rapid and quantitative analysis of pesticides in fruits by QuEChERS pretreatment and low-temperature plasma desorption/ionization orbitrap mass spectrometry
    Albert, Anastasia
    Kramer, Andrea
    Scheeren, Simon
    Engelhard, Carsten
    ANALYTICAL METHODS, 2014, 6 (15) : 5463 - 5471
  • [25] Development of an inverse low-temperature plasma ionization source for liquid chromatography/mass spectrometry
    Brecht, Dominik
    Uteschil, Florian
    Schmitz, Oliver J.
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2021, 35 (10)
  • [26] Effect of Ultrasonic Microdroplet Generation in the Low-Temperature Plasma Ionization-Mass Spectrometry
    Lee, Hyoung Jun
    Yim, Yong-Hyeon
    MASS SPECTROMETRY LETTERS, 2019, 10 (04) : 103 - 107
  • [27] Spray-inlet microwave plasma torch and low temperature plasma ionization for ambient mass spectrometry of agrochemicals
    Wang, Yaliang
    Xu, Li
    Zhu, Hui
    Dong, Junguo
    Cheng, Ping
    Zhou, Zhen
    ANALYTICAL METHODS, 2019, 11 (42) : 5421 - 5430
  • [28] Low-Temperature Plasma Ionization Differential Ion Mobility Spectrometry
    Kuklya, Andriy
    Engelhard, Carsten
    Uteschil, Florian
    Kerpen, Klaus
    Marks, Robert
    Telgheder, Ursula
    ANALYTICAL CHEMISTRY, 2015, 87 (17) : 8932 - 8940
  • [29] Rapid screening of active ingredients in drugs by mass spectrometry with low-temperature plasma probe
    Yueying Liu
    Ziqing Lin
    Sichun Zhang
    Chengdui Yang
    Xinrong Zhang
    Analytical and Bioanalytical Chemistry, 2009, 395 : 591 - 599
  • [30] Rapid screening of active ingredients in drugs by mass spectrometry with low-temperature plasma probe
    Liu, Yueying
    Lin, Ziqing
    Zhang, Sichun
    Yang, Chengdui
    Zhang, Xinrong
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2009, 395 (03) : 591 - 599