Comparison of intensity-modulated radiotherapy with conventional conformal radiotherapy for complex-shaped tumors

被引:129
|
作者
Pirzkall, A
Carol, M
Lohr, F
Höss, A
Wannenmacher, M
Debus, J
机构
[1] Univ Heidelberg, Dept Clin Radiol, Heidelberg, Germany
[2] German Canc Res Ctr, Dept Phys Med, D-6900 Heidelberg, Germany
[3] German Canc Res Ctr, Dept Radiat Oncol, D-6900 Heidelberg, Germany
关键词
intensity-modulated radiation therapy; 3D conformal radiotherapy (CRT); Inverse treatment planning; multileaf collimator (MLC); serial tomotherapy;
D O I
10.1016/S0360-3016(00)00772-0
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: Conformal and intensity-modulated radiotherapy (IMRT) plans for 9 patients were compared based on characterization of plan quality and effects on the oncology department. Methods and Materials: These clinical cases, treated originally with conformal radiotherapy (CRT), required extraordinary effort to produce conformal treatment plans using nonmodulated, shaped noncoplanar fields with multileaf collimators (MLCs). IMRT plans created for comparison included rotational treatments with slit collimator, and fixed-field MLC treatments using equispaced coplanar, and noncoplanar fields. Plans were compared based upon target coverage, target conformality, dose homogeneity, monitor units (MU), user-interactive planning time, and treatment delivery time. The results were subjected to a statistical analysis. Results: IMRT increased target coverage an average of 36% and conformality by 10%. Where dose escalation was a goal, IMRT increased mean dose by 4-6 Gy and target coverage by 19% with the same degree of conformality. Rotational IMRT was slightly superior to fixed-field IMRT. All IMRT techniques increased integral dose and target dose heterogeneity. IMRT planning times were significantly less, whereas MU increased significantly; estimated delivery times were similar. Conclusion: IMRT techniques increase dose and target coverage while continuing to spare organs-at-risk, and can be delivered in a time frame comparable to other sophisticated techniques. (C) 2000 Elsevier Science Inc.
引用
收藏
页码:1371 / 1380
页数:10
相关论文
共 50 条
  • [31] Dosimetric comparison of field in field intensity-modulated radiotherapy technique with conformal radiotherapy techniques in breast cancer
    Ercan, Tuelay
    Igdem, Sefik
    Alco, Guel
    Zengin, Funda
    Atilla, Selin
    Dincer, Maktav
    Okkan, Sait
    JAPANESE JOURNAL OF RADIOLOGY, 2010, 28 (04) : 283 - 289
  • [32] Dosimetric comparison of intensity-modulated radiotherapy and three-dimensional conformal radiotherapy for cerebral malignant gliomas
    Zheng, Ruifeng
    Fan, Ruitai
    Wen, Haiying
    Luo, Junbo
    Yang, Yang
    JOURNAL OF BUON, 2015, 20 (01): : 248 - 252
  • [33] Dosimetric comparison of field in field intensity-modulated radiotherapy technique with conformal radiotherapy techniques in breast cancer
    Tülay Ercan
    Şefik İğdem
    Gül Alço
    Funda Zengin
    Selin Atilla
    Maktav Dinçer
    Sait Okkan
    Japanese Journal of Radiology, 2010, 28 : 283 - 289
  • [34] Comparison of Intensity-Modulated Radiotherapy and 3-Dimensional Conformal Radiotherapy as Adjuvant Therapy for Gastric Cancer
    Minn, A. Yuriko
    Hsu, Annie
    La, Trang
    Kunz, Pamela
    Fisher, George A.
    Ford, James M.
    Norton, Jeffrey A.
    Visser, Brendan
    Goodman, Karyn A.
    Koong, Albert C.
    Chang, Daniel T.
    CANCER, 2010, 116 (16) : 3943 - 3952
  • [35] Intensity-modulated radiotherapy
    Leibel, SA
    Fuks, Z
    Zelefsky, MJ
    Wolden, SL
    Rosenzweig, KE
    Alektiar, KM
    Hunt, MA
    Yorke, ED
    Hong, LX
    Amols, HI
    Burman, CM
    Jackson, A
    Mageras, GS
    LoSasso, T
    Happersett, L
    Spirou, SV
    Chui, CS
    Ling, CC
    CANCER JOURNAL, 2002, 8 (02): : 164 - 176
  • [36] DOSIMETRIC COMPARISON OF VOLUMETRIC INTENSITY-MODULATED ARC (RAPIDARC) THERAPY, INTENSITY-MODULATED RADIOTHERAPY, AND 3D CONFORMAL RADIOTHERAPY FOR PRIMARY LIVER TUMOURS
    John, Jacob
    Sivasevan, Roshni
    Sudha, Arun Sankar
    Sivanandan, Choondal Devan
    Abdurahman, Sajeed
    Paramu, Raghukumar
    Sreedevi, Shaiju Vasudevan
    George, Preethi Sara
    Jayaprakash, Puthuveettil Govindan
    EUROPEAN JOURNAL OF CANCER, 2015, 51 : E34 - E34
  • [37] Optimisation of radiotherapy for carcinoma of the parotid gland: a comparison of conventional, three-dimensional conformal, and intensity-modulated techniques
    Nutting, CM
    Rowbottom, CG
    Cosgrove, VP
    Henk, JM
    Dearnaley, DP
    Robinson, MH
    Conway, J
    Webb, S
    RADIOTHERAPY AND ONCOLOGY, 2001, 60 (02) : 163 - 172
  • [38] Target coverage in head and neck cancer treated with intensity-modulated radiotherapy: A comparison between conventional and conformal techniques
    Palazzi, Mauro
    Orlandi, Ester
    Pignoli, Emanuele
    Lualdi, Manuela
    Zonca, Giancarlo
    Sangalli, Claudia
    Stucchi, Claudio
    Olmi, Patrizia
    TUMORI JOURNAL, 2006, 92 (06): : 503 - 510
  • [39] A comparison of intensity-modulated radiotherapy versus 3D conformal radiotherapy for prostate cancer patients whose rectal reaction to prior conventional radiotherapy was known
    Ozard, S
    Parker, W
    Patrocinio, H
    Faria, S
    Souhami, L
    MEDICAL PHYSICS, 2005, 32 (07) : 2410 - 2410
  • [40] Comparison of conventional radiotherapy and intensity-modulated radiotherapy for post-operative radiotherapy for primary extremity soft tissue sarcoma
    Stewart, Alexandra J.
    Lee, Young K.
    Saran, Frank H.
    RADIOTHERAPY AND ONCOLOGY, 2009, 93 (01) : 125 - 130