Optimisation of radiotherapy for carcinoma of the parotid gland: a comparison of conventional, three-dimensional conformal, and intensity-modulated techniques

被引:60
|
作者
Nutting, CM
Rowbottom, CG
Cosgrove, VP
Henk, JM
Dearnaley, DP
Robinson, MH
Conway, J
Webb, S
机构
[1] Inst Canc Res, Dept Radiotherapy, Sutton, Surrey, England
[2] Royal Marsden NHS Trust, Sutton, Surrey, England
[3] Inst Canc Res, Joint Dept Phys, Sutton, Surrey, England
[4] Weston Pk Hosp, YCR Dept Clin Oncol, Sheffield, S Yorkshire, England
[5] Weston Pk Hosp, Dept Radiotherapy Phys, Sheffield, S Yorkshire, England
关键词
parotid gland tumours; conventional radiotherapy; conformal radiotherapy; intensity-modulated radiotherapy; optimisation; radiotherapy technique;
D O I
10.1016/S0167-8140(01)00339-5
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Background and purpose: To compare external beam radiotherapy techniques for parotid gland tumours using conventional radiotherapy (RT), three-dimensional conformal radiotherapy (3DCRT), and intensity-modulated radiotherapy (IMRT). To optimise the IMRT techniques, and to produce an IMRT class solution. Materials and methods: The planning target volume (PTV), contra-lateral parotid gland, oral cavity, brain-stern, brain and cochlea were outlined on CT planning scans of six patients with parotid gland tumours. Optimised conventional RT and 3DCRT plans were created and compared with inverse-planned IMRT dose distributions using dose-volume histograms. The aim was to reduce the radiation dose to organs at risk and improve the PTV dose distribution. A beam-direction optimisation algorithm was used to improve the dose distribution of the IMRT plans, and a class solution for parotid gland IMRT was investigated. Results: 3DCRT plans produced an equivalent PTV irradiation and reduced the dose to the cochlea, oral cavity, brain, and other normal tissues compared with conventional RT. IMRT further reduced the radiation dose to the cochlea and oral cavity compared with 3DCRT. For nine- and seven-field IMRT techniques, there was an increase in low-dose radiation to non-target tissue and the contra-lateral parotid gland. IMRT plans produced using three to five optimised intensity-modulated beam directions maintained the advantages of the more complex IMRT plans, and reduced the contra-lateral parotid gland dose to acceptable levels. Three- and four-field non-coplanar beam arrangements increased the volume of brain irradiated, and increased PTV dose inhomogeneity. A four-field class solution consisting of paired ipsilateral coplanar anterior and posterior oblique beams (15, 45, 145 and 170 degrees from the anterior plane) was developed which maintained the benefits without the complexity of individual patient optimisation. Conclusions: For patients with parotid gland tumours, reduction in the radiation dose to critical normal tissues was demonstrated with 3DCRT compared with conventional RT. IMRT produced a further reduction in the dose to the cochlea and oral cavity. With nine and seven fields, the dose to the contra-lateral parotid gland was increased, but this was avoided by optimisation of the beam directions. The benefits of IMRT were maintained with three or four fields when the beam angles were optimised, but were also achieved using a four-field class solution. Clinical trials are required to confirm the clinical benefits of these improved dose distributions. (C) 2001 Elsevier Science Ireland Ltd. All rights reserved.
引用
收藏
页码:163 / 172
页数:10
相关论文
共 50 条
  • [1] Effect of three-dimensional conformal radiotherapy and intensity-modulated radiotherapy on parotid gland function and quality of life in patients with nasopharyngeal carcinoma
    Zheng, Lirong
    Tong, Lei
    Due, Fenglei
    Ren, Huijun
    Xiao, Lin
    [J]. AMERICAN JOURNAL OF TRANSLATIONAL RESEARCH, 2021, 13 (05): : 5272 - 5279
  • [2] Intensity-modulated three-dimensional conformal radiotherapy
    Mohan, R
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1997, 39 (02): : 121 - 121
  • [3] Intensity-modulated radiotherapy versus conventional three-dimensional conformal radiotherapy for boost or salvage treatment of nasopharyngeal carcinoma
    Hsiung, CY
    Yorke, ED
    Chui, CS
    Hunt, MA
    Ling, CC
    Huang, EY
    Wang, CJ
    Chen, HC
    Yeh, SA
    Hsu, HC
    Amols, HI
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2002, 53 (03): : 638 - 647
  • [4] Dosimetric Comparison of Intensity-Modulated Radiotherapy, Volumetric Modulated Arc Therapy and Hybrid Three-Dimensional Conformal Radiotherapy/Intensity-Modulated Radiotherapy Techniques for Right Breast Cancer
    Liu, Yi-Chi
    Chang, Hung-Ming
    Lin, Hsin-Hon
    Lu, Chia-Chun
    Lai, Lu-Han
    [J]. JOURNAL OF CLINICAL MEDICINE, 2020, 9 (12) : 1 - 14
  • [5] Comparison of treatment plans using intensity-modulated radiotherapy and three-dimensional conformal radiotherapy for paranasal sinus carcinoma
    Huang, D
    Xia, P
    Akazawa, P
    Akazawa, C
    Quivey, JM
    Verhey, LJ
    Kaplan, M
    Lee, N
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2003, 56 (01): : 158 - 168
  • [6] Dosimetric comparison of intensity-modulated radiotherapy and three-dimensional conformal radiotherapy for cerebral malignant gliomas
    Zheng, Ruifeng
    Fan, Ruitai
    Wen, Haiying
    Luo, Junbo
    Yang, Yang
    [J]. JOURNAL OF BUON, 2015, 20 (01): : 248 - 252
  • [7] Comparison of Acute Gastrointestinal Toxicity of Intensity-Modulated Radiotherapy Versus Three-Dimensional Conformal Radiotherapy in Patients of Carcinoma Cervix
    Padhi, Sanjukta
    Mahapatra, Bikash Ranjan
    Pati, Kartik Chandra
    Sahoo, Bijayalaxmi
    Kanungo, Satuanrata
    Mishra, Tanushree
    Muraleedharan, Anupam
    [J]. CUREUS JOURNAL OF MEDICAL SCIENCE, 2023, 15 (11)
  • [8] DOSIMETRIC COMPARISON OF THREE-DIMENSIONAL CONFORMAL PROTON RADIOTHERAPY, INTENSITY-MODULATED PROTON THERAPY, AND INTENSITY-MODULATED RADIOTHERAPY FOR TREATMENT OF PEDIATRIC CRANIOPHARYNGIOMAS
    Boehling, Nicholas S.
    Grosshans, David R.
    Bluett, Jaques B.
    Palmer, Matthew T.
    Song, Xiaofei
    Amos, Richard A.
    Sahoo, Narayan
    Meyer, Jeffrey J.
    Mahajan, Anita
    Woo, Shiao Y.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2012, 82 (02): : 643 - 652
  • [9] VOLUMETRIC MODULATED ARC THERAPY FOR DELIVERY OF PROSTATE RADIOTHERAPY: COMPARISON WITH INTENSITY-MODULATED RADIOTHERAPY AND THREE-DIMENSIONAL CONFORMAL RADIOTHERAPY
    Palma, David
    Vollans, Emily
    James, Kerry
    Nakano, Sandy
    Moiseenko, Vitali
    Shaffer, Richard
    Mckenzie, Michael
    Morris, James
    Otto, Karl
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2008, 72 (04): : 996 - 1001
  • [10] A comparison of conformal and intensity-modulated techniques for oesophageal radiotherapy
    Nutting, CM
    Bedford, JL
    Cosgrove, VP
    Tait, DM
    Dearnaley, DP
    Webb, S
    [J]. RADIOTHERAPY AND ONCOLOGY, 2001, 61 (02) : 157 - 163