Optimisation of radiotherapy for carcinoma of the parotid gland: a comparison of conventional, three-dimensional conformal, and intensity-modulated techniques

被引:60
|
作者
Nutting, CM
Rowbottom, CG
Cosgrove, VP
Henk, JM
Dearnaley, DP
Robinson, MH
Conway, J
Webb, S
机构
[1] Inst Canc Res, Dept Radiotherapy, Sutton, Surrey, England
[2] Royal Marsden NHS Trust, Sutton, Surrey, England
[3] Inst Canc Res, Joint Dept Phys, Sutton, Surrey, England
[4] Weston Pk Hosp, YCR Dept Clin Oncol, Sheffield, S Yorkshire, England
[5] Weston Pk Hosp, Dept Radiotherapy Phys, Sheffield, S Yorkshire, England
关键词
parotid gland tumours; conventional radiotherapy; conformal radiotherapy; intensity-modulated radiotherapy; optimisation; radiotherapy technique;
D O I
10.1016/S0167-8140(01)00339-5
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Background and purpose: To compare external beam radiotherapy techniques for parotid gland tumours using conventional radiotherapy (RT), three-dimensional conformal radiotherapy (3DCRT), and intensity-modulated radiotherapy (IMRT). To optimise the IMRT techniques, and to produce an IMRT class solution. Materials and methods: The planning target volume (PTV), contra-lateral parotid gland, oral cavity, brain-stern, brain and cochlea were outlined on CT planning scans of six patients with parotid gland tumours. Optimised conventional RT and 3DCRT plans were created and compared with inverse-planned IMRT dose distributions using dose-volume histograms. The aim was to reduce the radiation dose to organs at risk and improve the PTV dose distribution. A beam-direction optimisation algorithm was used to improve the dose distribution of the IMRT plans, and a class solution for parotid gland IMRT was investigated. Results: 3DCRT plans produced an equivalent PTV irradiation and reduced the dose to the cochlea, oral cavity, brain, and other normal tissues compared with conventional RT. IMRT further reduced the radiation dose to the cochlea and oral cavity compared with 3DCRT. For nine- and seven-field IMRT techniques, there was an increase in low-dose radiation to non-target tissue and the contra-lateral parotid gland. IMRT plans produced using three to five optimised intensity-modulated beam directions maintained the advantages of the more complex IMRT plans, and reduced the contra-lateral parotid gland dose to acceptable levels. Three- and four-field non-coplanar beam arrangements increased the volume of brain irradiated, and increased PTV dose inhomogeneity. A four-field class solution consisting of paired ipsilateral coplanar anterior and posterior oblique beams (15, 45, 145 and 170 degrees from the anterior plane) was developed which maintained the benefits without the complexity of individual patient optimisation. Conclusions: For patients with parotid gland tumours, reduction in the radiation dose to critical normal tissues was demonstrated with 3DCRT compared with conventional RT. IMRT produced a further reduction in the dose to the cochlea and oral cavity. With nine and seven fields, the dose to the contra-lateral parotid gland was increased, but this was avoided by optimisation of the beam directions. The benefits of IMRT were maintained with three or four fields when the beam angles were optimised, but were also achieved using a four-field class solution. Clinical trials are required to confirm the clinical benefits of these improved dose distributions. (C) 2001 Elsevier Science Ireland Ltd. All rights reserved.
引用
收藏
页码:163 / 172
页数:10
相关论文
共 50 条
  • [31] Adjuvant external beam radiotherapy after therapeutic groin lymphadenectomy for patients with melanoma: a dosimetric comparison of three-dimensional conformal and intensity-modulated radiotherapy techniques
    Adams, Gerard
    Foote, Matthew
    Brown, Simon
    Burmeister, Bryan
    MELANOMA RESEARCH, 2017, 27 (01) : 50 - 56
  • [32] Comparison of conformal and intensity-modulated techniques for simultaneous integrated boost radiotherapy of upper esophageal carcinoma
    Fu, Wei-Hua
    Wang, Lu-Hua
    Zhou, Zong-Mei
    Dai, Jian-Rong
    Hu, Yi-Min
    Zhao, Lu-Jun
    WORLD JOURNAL OF GASTROENTEROLOGY, 2004, 10 (08) : 1098 - 1102
  • [33] A Retrospective Comparison of Toxicity, Response and Survival of Intensity-Modulated Radiotherapy Versus Three-Dimensional Conformal Radiation Therapy in the Treatment of Rectal Carcinoma
    Kouklidis, Georgios
    Nikolopoulos, Manolis
    Ahmed, Omer
    Eskander, Boulos
    Masters, Ben
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2023, 15 (11)
  • [34] Comparison of conformal and intensity-modulated techniques for simultaneous integrated boost radiotherapy of upper esophageal carcinoma
    Wei-Hua Fu Lu-Hua Wang Zong-Mei Zhou Jian-Rong Dai Yi-Min Hu Lu-Jun Zhao Department of Radiation Oncology
    World Journal of Gastroenterology, 2004, (08) : 1098 - 1102
  • [35] Dosimetric comparison of three-dimensional conformal radiotherapy and intensity-modulated radiotherapy for left-sided chest wall and lymphatic irradiation
    Kivanc, Huseyin
    Gultekin, Melis
    Gurkaynak, Murat
    Ozyigit, Gokhan
    Yildiz, Ferah
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2019, 20 (12): : 36 - 44
  • [36] A Model of the Cost-effectiveness of Intensity-modulated Radiotherapy in Comparison with Three-dimensional Conformal Radiotherapy for the Treatment of Localised Prostate Cancer
    Hummel, S. R.
    Stevenson, M. D.
    Simpson, E. L.
    Staffurth, J.
    CLINICAL ONCOLOGY, 2012, 24 (10) : E159 - E167
  • [37] Intensity-Modulated Radiotherapy versus Three-Dimensional Conformal Radiotherapy in Definitive Chemoradiotherapy for Cervical Esophageal Squamous Cell Carcinoma: Comparison of Survival Outcomes and Toxicities
    Chen, Nai-Bin
    Qiu, Bo
    Zhang, Jun
    Qiang, Meng-Yun
    Zhu, Yu-Jia
    Wang, Bin
    Guo, Jin-Yu
    Cai, Ling-Zhi
    Huang, Shao-Min
    Liu, Meng-Zhong
    Li, Qun
    Hu, Yong-Hong
    Li, Qi-Wen
    Liu, Hui
    CANCER RESEARCH AND TREATMENT, 2020, 52 (01): : 31 - 40
  • [38] Three-dimensional conformal radiotherapy, static intensity-modulated and helical intensity-modulated radiotherapy in glioblastoma. Dosimetric comparison in patients with overlap between target volumes and organs at risk
    Buglione, Michela
    Spiazzi, Luigi
    Saiani, Federica
    Costa, Loredana
    Shehi, Blerina
    Lazzari, Barbara
    Uccelli, Chiara
    Pasinetti, Nadia
    Borghetti, Paolo
    Triggiani, Luca
    Donadoni, Laura
    Pedretti, Sara
    Magrini, Stefano M.
    TUMORI, 2014, 100 (03) : 272 - 277
  • [39] Intensity-Modulated Versus Three-Dimensional Conformal Radiotherapy for Cervical Cancer: National Trend and Survival
    Wang, Y., Jr.
    Ballo, M. T.
    Hubler, A.
    Somer, B.
    Tillmanns, T.
    Farmer, M. R.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2019, 105 (01): : E339 - E340
  • [40] Comparison of conformal radiotherapy, intensity-modulated radiotherapy and tomotherapy irradiation techniques in prostate cancers
    Tugrul, Taylan
    Olacak, Nezahat
    Koylu, Murat
    JOURNAL OF RADIOTHERAPY IN PRACTICE, 2019, 18 (03) : 276 - 279