Adjuvant external beam radiotherapy after therapeutic groin lymphadenectomy for patients with melanoma: a dosimetric comparison of three-dimensional conformal and intensity-modulated radiotherapy techniques

被引:3
|
作者
Adams, Gerard [1 ,2 ]
Foote, Matthew [1 ,2 ]
Brown, Simon [1 ]
Burmeister, Bryan [1 ,2 ]
机构
[1] Princess Alexandra Hosp, Radiat Oncol Canc Serv, Brisbane, Qld, Australia
[2] Univ Queensland, Sch Med, St Lucia, Qld, Australia
关键词
adjuvant; groin; intensity-modulated radiotherapy; lymphadenectomy; lymph node; melanoma; radiotherapy; three-dimensional conformal radiotherapy; RADIATION-THERAPY; PHASE-2; CANCER; TROG; IMRT;
D O I
10.1097/CMR.0000000000000304
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Radiotherapy after lymph node dissection is recommended in high-risk melanoma cases. The aim of this study is to assess whether intensity-modulated radiotherapy (IMRT) offers advantages over three-dimensional conformal radiotherapy (3DCRT) in the groin nodal basin. Fifteen consecutively treated patients (5 3DCRT and 10 IMRT) were selected. Optimized theoretical plans using the other modality were created - enabling direct comparisons of 3DCRT and IMRT. Target volume and organs at risk constraints were assessed as achieved or as having minor (<= 5%) or major (> 5%) deviations. The Wilcoxon signed-rank test was used to compare the dose received from each patient plan (3DCRT vs. IMRT), whereas the Mann-Whitney U-test was used to compare clinical plans with theoretical plans. Fisher's exact test was used to compare categorical data. Target coverage was achievable in most patients (major deviations - 1 IMRT and 3 3DCRT). Conformity index improved with IMRT - median 0.65, range 0.48-0.81, versus median 0.44, range 0.29-0.60 for 3DCRT; P value less than 0.001. All 3DCRT plans had major deviations for femoral head/neck constraints. Twelve and 13 IMRT plans achieved the high (V42<5%) and low (V36<35%) constraints; P value less than 0.001. IMRT delivered statistically significant lower doses to small bowel volumes up to 40 ml. There were no differences in beam numbers used nor dosimetric endpoints measured when clinical plans were compared with theoretical plans. IMRT appears to allow superior conformity of dose to the target volume while relatively sparing the adjacent the bowel and femoral head/neck. This may reduce toxicity while maintaining control rates. Melanoma Res 27: 50-56 Copyright (C) 2017 Wolters Kluwer Health, Inc. All rights reserved.
引用
收藏
页码:50 / 56
页数:7
相关论文
共 50 条
  • [1] Dosimetric Comparison of Three Different External Beam Partial Breast Irradiation Techniques: Three-Dimensional Conformal Radiotherapy, Intensity-Modulated Radiotherapy and Volumetric Modulated Arc Radiotherapy
    Sun, T.
    Li, J.
    Xu, M.
    Liu, T.
    Lin, X.
    Zhang, G.
    [J]. MEDICAL PHYSICS, 2011, 38 (06) : 3682 - +
  • [2] Dosimetric comparison of intensity-modulated radiotherapy and three-dimensional conformal radiotherapy for cerebral malignant gliomas
    Zheng, Ruifeng
    Fan, Ruitai
    Wen, Haiying
    Luo, Junbo
    Yang, Yang
    [J]. JOURNAL OF BUON, 2015, 20 (01): : 248 - 252
  • [3] Dosimetric Comparison of Intensity-Modulated Radiotherapy, Volumetric Modulated Arc Therapy and Hybrid Three-Dimensional Conformal Radiotherapy/Intensity-Modulated Radiotherapy Techniques for Right Breast Cancer
    Liu, Yi-Chi
    Chang, Hung-Ming
    Lin, Hsin-Hon
    Lu, Chia-Chun
    Lai, Lu-Han
    [J]. JOURNAL OF CLINICAL MEDICINE, 2020, 9 (12) : 1 - 14
  • [4] Determination and comparison of dosimetric parameters of three-dimensional conformal radiotherapy, field in field, and intensity-modulated radiotherapy techniques in radiotherapy of breast conserving patients
    Takabi, Fatemeh Shirani
    Broomand, Mohammad Ali
    Nickfarjam, Abolfazl
    Asadi, Amin
    Namiranian, Nasim
    [J]. JOURNAL OF CANCER RESEARCH AND THERAPEUTICS, 2023, 19 (03) : 624 - 632
  • [6] Adjuvant radiotherapy for gallbladder cancer: A dosimetric comparison of conformal radiotherapy and intensity-modulated radiotherapy
    Sun, Xiao-Nan
    Wang, Qi
    Gu, Ben-Xing
    Zhu, Yan-Hong
    Hu, Jian-Bin
    Shi, Guo-Zhi
    Zheng, Shu
    [J]. WORLD JOURNAL OF GASTROENTEROLOGY, 2011, 17 (03) : 397 - 402
  • [7] Dosimetric comparison of four different external beam partial breast irradiation techniques: Three-dimensional conformal radiotherapy, intensity-modulated radiotherapy, helical tomotherapy, and proton beam therapy
    Moon, Sung Ho
    Shin, Kyung Hwan
    Kim, Tae Hyun
    Yoon, Myonggeun
    Park, Soah
    Lee, Doo-Hyun
    Kim, Jong Won
    Kim, Dae Woong
    Park, Sung Yong
    Cho, Kwan Ho
    [J]. RADIOTHERAPY AND ONCOLOGY, 2009, 90 (01) : 66 - 73
  • [8] DOSIMETRIC COMPARISON OF THREE-DIMENSIONAL CONFORMAL PROTON RADIOTHERAPY, INTENSITY-MODULATED PROTON THERAPY, AND INTENSITY-MODULATED RADIOTHERAPY FOR TREATMENT OF PEDIATRIC CRANIOPHARYNGIOMAS
    Boehling, Nicholas S.
    Grosshans, David R.
    Bluett, Jaques B.
    Palmer, Matthew T.
    Song, Xiaofei
    Amos, Richard A.
    Sahoo, Narayan
    Meyer, Jeffrey J.
    Mahajan, Anita
    Woo, Shiao Y.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2012, 82 (02): : 643 - 652
  • [9] Intensity-modulated three-dimensional conformal radiotherapy
    Mohan, R
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1997, 39 (02): : 121 - 121
  • [10] Dosimetric Comparison of Three-Dimensional Conformal Radiotherapy with Hybrid Intensity-Modulated Radiotherapy Techniques for Treatment of Locally Advanced Lung Cancer
    Suyunmez, Ozge
    Genc, Mine
    Ciftlikli, Ozlem Toykan
    Tuncel, Nina
    [J]. TURK ONKOLOJI DERGISI-TURKISH JOURNAL OF ONCOLOGY, 2022, 37 (03): : 239 - 245