Optimisation of radiotherapy for carcinoma of the parotid gland: a comparison of conventional, three-dimensional conformal, and intensity-modulated techniques

被引:60
|
作者
Nutting, CM
Rowbottom, CG
Cosgrove, VP
Henk, JM
Dearnaley, DP
Robinson, MH
Conway, J
Webb, S
机构
[1] Inst Canc Res, Dept Radiotherapy, Sutton, Surrey, England
[2] Royal Marsden NHS Trust, Sutton, Surrey, England
[3] Inst Canc Res, Joint Dept Phys, Sutton, Surrey, England
[4] Weston Pk Hosp, YCR Dept Clin Oncol, Sheffield, S Yorkshire, England
[5] Weston Pk Hosp, Dept Radiotherapy Phys, Sheffield, S Yorkshire, England
关键词
parotid gland tumours; conventional radiotherapy; conformal radiotherapy; intensity-modulated radiotherapy; optimisation; radiotherapy technique;
D O I
10.1016/S0167-8140(01)00339-5
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Background and purpose: To compare external beam radiotherapy techniques for parotid gland tumours using conventional radiotherapy (RT), three-dimensional conformal radiotherapy (3DCRT), and intensity-modulated radiotherapy (IMRT). To optimise the IMRT techniques, and to produce an IMRT class solution. Materials and methods: The planning target volume (PTV), contra-lateral parotid gland, oral cavity, brain-stern, brain and cochlea were outlined on CT planning scans of six patients with parotid gland tumours. Optimised conventional RT and 3DCRT plans were created and compared with inverse-planned IMRT dose distributions using dose-volume histograms. The aim was to reduce the radiation dose to organs at risk and improve the PTV dose distribution. A beam-direction optimisation algorithm was used to improve the dose distribution of the IMRT plans, and a class solution for parotid gland IMRT was investigated. Results: 3DCRT plans produced an equivalent PTV irradiation and reduced the dose to the cochlea, oral cavity, brain, and other normal tissues compared with conventional RT. IMRT further reduced the radiation dose to the cochlea and oral cavity compared with 3DCRT. For nine- and seven-field IMRT techniques, there was an increase in low-dose radiation to non-target tissue and the contra-lateral parotid gland. IMRT plans produced using three to five optimised intensity-modulated beam directions maintained the advantages of the more complex IMRT plans, and reduced the contra-lateral parotid gland dose to acceptable levels. Three- and four-field non-coplanar beam arrangements increased the volume of brain irradiated, and increased PTV dose inhomogeneity. A four-field class solution consisting of paired ipsilateral coplanar anterior and posterior oblique beams (15, 45, 145 and 170 degrees from the anterior plane) was developed which maintained the benefits without the complexity of individual patient optimisation. Conclusions: For patients with parotid gland tumours, reduction in the radiation dose to critical normal tissues was demonstrated with 3DCRT compared with conventional RT. IMRT produced a further reduction in the dose to the cochlea and oral cavity. With nine and seven fields, the dose to the contra-lateral parotid gland was increased, but this was avoided by optimisation of the beam directions. The benefits of IMRT were maintained with three or four fields when the beam angles were optimised, but were also achieved using a four-field class solution. Clinical trials are required to confirm the clinical benefits of these improved dose distributions. (C) 2001 Elsevier Science Ireland Ltd. All rights reserved.
引用
下载
收藏
页码:163 / 172
页数:10
相关论文
共 50 条
  • [21] Integral Dose Variation in Three-dimensional Conformal Radiotherapy, Intensity-modulated Radiotherapy, and Helical Tomotherapy
    Yang, R.
    Xu, S.
    Jiang, W.
    Zhou, G.
    Wang, J.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2009, 75 (03): : S713 - S713
  • [22] Integral Dose Variation in Three-Dimensional Conformal Radiotherapy, Intensity-Modulated Radiotherapy, and Helical Tomotherapy
    Yang, R.
    Wang, J.
    Xu, S.
    MEDICAL PHYSICS, 2009, 36 (06)
  • [23] Clinical and dosimetric study of radiotherapy for glioblastoma: three-dimensional conformal radiotherapy versus intensity-modulated radiotherapy
    Thibouw, David
    Truc, Gilles
    Bertaut, Aurelie
    Chevalier, Cedric
    Aubignac, Leone
    Mirjolet, Celine
    JOURNAL OF NEURO-ONCOLOGY, 2018, 137 (02) : 429 - 438
  • [24] Clinical and dosimetric study of radiotherapy for glioblastoma: three-dimensional conformal radiotherapy versus intensity-modulated radiotherapy
    David Thibouw
    Gilles Truc
    Aurélie Bertaut
    Cédric Chevalier
    Léone Aubignac
    Céline Mirjolet
    Journal of Neuro-Oncology, 2018, 137 : 429 - 438
  • [25] Superiority of intensity-modulated radiotherapy over three-dimensional conformal radiotherapy combined with brachytherapy in nasopharyngeal carcinoma:: a planning study
    Taheri-Kadkhoda, Z.
    Pettersson, N.
    Bjoerk-Eriksson, T.
    Johansson, K-A
    BRITISH JOURNAL OF RADIOLOGY, 2008, 81 (965): : 397 - 405
  • [26] Three dimensional conformal postoperative radiotherapy for unilateral parotid gland cancer: A comparison of three different parotid gland irradiation techniques
    Helal, Azza
    Omar, Abbas
    ALEXANDRIA JOURNAL OF MEDICINE, 2013, 49 (04): : 379 - 384
  • [27] Superiority of helical tomotherapy on liver sparing and dose escalation in hepatocellular carcinoma: a comparison study of three-dimensional conformal radiotherapy and intensity-modulated radiotherapy
    Zhao, Qianqian
    Wang, Renben
    Zhu, Jian
    Jin, Linzhi
    Zhu, Kunli
    Xu, Xiaoqing
    Feng, Rui
    Jiang, Shumei
    Qi, Zhonghua
    Yin, Yong
    ONCOTARGETS AND THERAPY, 2016, 9 : 3807 - 3813
  • [28] Dosimetric Comparison of Three-Dimensional Conformal Radiotherapy and Intensity Modulated Radiotherapy for Paediatric Neuroblastoma
    Jiang, M.
    PEDIATRIC BLOOD & CANCER, 2016, 63 : S196 - S196
  • [29] Nasopharyngeal carcinoma in children: Comparison of conventional and intensity-modulated radiotherapy
    Laskar, Siddhartha
    Bahl, Gaurav
    Muckaden, Maryann
    Pai, Suresh K.
    Gupta, Tejpal
    Banavali, Shripad
    Arora, Brijesh
    Sharma, Dayanand
    Kurkure, Purna A.
    Ramadwar, Mukta
    Viswanathan, Seethalaxhmi
    Rangarajan, Venkatesh
    Qureshi, Sajid
    Deshpande, Deepak D.
    Shrivastava, Shyam K.
    Dinshaw, Ketayun A.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2008, 72 (03): : 728 - 736
  • [30] Comparison of intensity-modulated radiotherapy with conventional conformal radiotherapy for complex-shaped tumors
    Pirzkall, A
    Carol, M
    Lohr, F
    Höss, A
    Wannenmacher, M
    Debus, J
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2000, 48 (05): : 1371 - 1380