Physical properties of a new flat panel detector with cesium-iodide technology

被引:0
|
作者
Hahn, Andreas [1 ]
Penchev, Petar [1 ]
Fiebich, Martin [1 ]
机构
[1] Univ Appl Sci, Inst Med Phys & Radiat Protect, Wiesenstr 14, D-35390 Giessen, Germany
关键词
Digital radiology; modulation transfer function; detective quantum efficiency; COMPUTED RADIOGRAPHY; PERFORMANCE; SYSTEMS;
D O I
10.1117/12.2216829
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Flat panel detectors have become the standard technology in projection radiography. Further progress in detector technology will result in an improvement of MTF and DQE. The new detector (DX-D45C; Agfa; Mortsel/Belgium) is based on cesium-iodine crystals and has a change in the detector material and the readout electronics. The detector has a size of 30 cm x 24 cm and a pixel matrix of 2560 x 2048 with a pixel pitch of 124 lam. The system includes an automatic exposure detector, which enables the use of the detector without a connection to the x-ray generator. The physical properties of the detector were determined following IEC 62220-1-1 in a laboratory setting. The MTF showed an improvement compared to the previous version of cesium-iodine based flat-panel detectors. Thereby the DQE is also improved especially for the higher frequencies. The new detector showed an improvement in the physical properties compared to the previous versions. This enables a potential for further dose reductions in clinical imaging.
引用
收藏
页数:5
相关论文
共 50 条
  • [31] An Experimental Comparison of Flat-Panel Detector Performance for Direct and Indirect Systems (Initial Experiences and Physical Evaluation)
    Tsutomu Gomi
    Kichirou Koshida
    Tosiaki Miyati
    Jun Miyagawa
    Hiroshi Hirano
    Journal of Digital Imaging, 2006, 19
  • [32] An experimental comparison of flat-panel detector performance for direct and indirect systems (initial experiences and physical evaluation)
    Gomi, Tsutomu
    Koshida, Kichirou
    Miyati, Tosiaki
    Miyagawa, Jun
    Hirano, Hiroshi
    JOURNAL OF DIGITAL IMAGING, 2006, 19 (04) : 362 - 370
  • [33] Physical characteristics of a clinical prototype for full-field digital mammography with an a-Se flat panel detector
    Lazzari, B
    Belli, G
    Gori, C
    Nykdnen, K
    MEDICAL IMAGING 2003: PHYSICS OF MEDICAL IMAGING, PTS 1 AND 2, 2003, 5030 : 656 - 666
  • [34] a-Si:H HEX-TFTs, a new technology for flat panel displays
    Lee, Hojin
    Yoo, Juhn S.
    Kim, C. -D.
    Kang, In Byeong
    Kanicki, Jerzy
    IDW '07: PROCEEDINGS OF THE 14TH INTERNATIONAL DISPLAY WORKSHOPS, VOLS 1-3, 2007, : 1993 - +
  • [35] The Simulation Study of New Flat Panel Detector Structure for Reducing Scattered Radiation Using Anthropomorphic Phantom
    Roh, Y.
    Jung, H.
    Kim, G.
    Park, M.
    Park, S.
    Ji, Y.
    Joo, K.
    Kim, J.
    MEDICAL PHYSICS, 2017, 44 (06) : 2983 - 2983
  • [36] Clinical translation of a new flat-panel detector for beam's-eye-view imaging
    Harris, T. C.
    Seco, J.
    Ferguson, D.
    Lehmann, M.
    Huber, P.
    Shi, M.
    Jacobson, M.
    Lozano, I. Valencia
    Myronakis, M.
    Baturin, P.
    Fueglistaller, R.
    Morf, D.
    Berbeco, R.
    PHYSICS IN MEDICINE AND BIOLOGY, 2020, 65 (22):
  • [37] Full breast digital mammography with an amorphous silicon-based flat panel detector: Physical characteristics of a clinical prototype
    Vedantham, S
    Karellas, A
    Suryanarayanan, S
    Albagli, D
    Han, S
    Tkaczyk, EJ
    Landberg, CE
    Opsahl-Ong, B
    Granfors, PR
    Levis, I
    D'Orsi, CJ
    Hendrick, RE
    MEDICAL PHYSICS, 2000, 27 (03) : 558 - 567
  • [38] Chest imaging with flat-panel detector at low and standard doses: comparison with storage phosphor technology in normal patients
    K. Herrmann
    H. Bonél
    A. Stäbler
    C. Kulinna
    C. Glaser
    N. Holzknecht
    B. Geiger
    M. Schätzl
    M. Reiser
    European Radiology, 2002, 12 : 385 - 390
  • [39] Chest imaging with flat-panel detector at low and standard doses:: comparison with storage phosphor technology in normal patients
    Herrmann, KA
    Bonél, H
    Stäbler, A
    Kulinna, C
    Glaser, C
    Holzknecht, N
    Geiger, B
    Schätzl, M
    Reiser, MF
    EUROPEAN RADIOLOGY, 2002, 12 (02) : 385 - 390
  • [40] Aging of imaging properties of a CMOS flat-panel detector for dental cone-beam computed tomography
    Kim, D. W.
    Han, J. C.
    Yun, S.
    Kim, H. K.
    JOURNAL OF INSTRUMENTATION, 2017, 12