Physical properties of a new flat panel detector with cesium-iodide technology

被引:0
|
作者
Hahn, Andreas [1 ]
Penchev, Petar [1 ]
Fiebich, Martin [1 ]
机构
[1] Univ Appl Sci, Inst Med Phys & Radiat Protect, Wiesenstr 14, D-35390 Giessen, Germany
关键词
Digital radiology; modulation transfer function; detective quantum efficiency; COMPUTED RADIOGRAPHY; PERFORMANCE; SYSTEMS;
D O I
10.1117/12.2216829
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Flat panel detectors have become the standard technology in projection radiography. Further progress in detector technology will result in an improvement of MTF and DQE. The new detector (DX-D45C; Agfa; Mortsel/Belgium) is based on cesium-iodine crystals and has a change in the detector material and the readout electronics. The detector has a size of 30 cm x 24 cm and a pixel matrix of 2560 x 2048 with a pixel pitch of 124 lam. The system includes an automatic exposure detector, which enables the use of the detector without a connection to the x-ray generator. The physical properties of the detector were determined following IEC 62220-1-1 in a laboratory setting. The MTF showed an improvement compared to the previous version of cesium-iodine based flat-panel detectors. Thereby the DQE is also improved especially for the higher frequencies. The new detector showed an improvement in the physical properties compared to the previous versions. This enables a potential for further dose reductions in clinical imaging.
引用
收藏
页数:5
相关论文
共 50 条
  • [21] Evaluation of a new radiographic system based on a flat panel X-ray detector
    Maack, I
    GuntherKohfahl, S
    Schroeder, H
    Spiess, K
    Neitzel, U
    RADIOLOGY, 1997, 205 : 109 - 109
  • [22] Basic evaluation of physical characteristic and clinical study of New Digital Subtraction Angiography system with a large-area Flat Panel Detector
    Okusako, K
    Shogaki, M
    Tanaka, K
    Yokoyama, K
    Ichida, T
    Okuyama, K
    Kudoh, H
    Tanaka, S
    Nakamura, K
    Ikeda, S
    MEDICAL IMAGING 2003: PHYSICS OF MEDICAL IMAGING, PTS 1 AND 2, 2003, 5030 : 845 - 852
  • [23] Should 3K zoom function be used for detection of pneumothorax in cesium iodide/amorphous silicon flat-panel detector radiographs presented on 1K-matrix soft copies?
    Karin A. Herrmann
    H. M. Bonél
    A. Stäbler
    M. Voelk
    M. Strotzer
    C. J. Zech
    M. F. Reiser
    European Radiology, 2006, 16
  • [24] Clinical evaluation of digital radiography based on a large-area cesium iodide-amorphous silicon flat-panel detector compared with screen-film radiography for skeletal system and abdomen
    Okamura, T
    Tanaka, S
    Koyama, K
    Norihumi, N
    Daikokuya, H
    Matsuoka, T
    Kishimoto, K
    Hatagawa, M
    Kudoh, H
    Yamada, R
    EUROPEAN RADIOLOGY, 2002, 12 (07) : 1741 - 1747
  • [25] Clinical evaluation of digital radiography based on a large-area cesium iodide-amorphous silicon flat-panel detector compared with screen-film radiography for skeletal system and abdomen
    Terue Okamura
    Saori Tanaka
    Koichi Koyama
    Nishida Norihumi
    Hideo Daikokuya
    Toshiyuki Matsuoka
    Kenji Kishimoto
    Masakatsu Hatagawa
    Hiroaki Kudoh
    Ryusaku Yamada
    European Radiology, 2002, 12 : 1741 - 1747
  • [26] Should 3K zoom function be used for detection of pneumothorax in cesium iodide/amorphous silicon flat-panel detector radiographs presented on 1K-matrix soft copies?
    Herrmann, Karin A.
    Bonel, H. M.
    Staebler, A.
    Voelk, M.
    Strotzer, M.
    Zech, C. J.
    Reiser, M. F.
    EUROPEAN RADIOLOGY, 2006, 16 (12) : 2768 - 2774
  • [27] Evaluation of the imaging properties of an amorphous selenium-based flat panel detector for digital fluoroscopy
    Hunt, DC
    Tousignant, O
    Rowlands, JA
    MEDICAL PHYSICS, 2004, 31 (05) : 1166 - 1175
  • [28] Contrast-detail detection of a new digital flat-panel detector: a ROC Study
    Kotter, E
    Uhrmeister, P
    Winterer, J
    Hauer, M
    Streng, W
    Langer, M
    CARS '99: COMPUTER ASSISTED RADIOLOGY AND SURGERY, 1999, 1191 : 19 - 22
  • [29] New 43 cm x 43 cm flat panel digital detector for general radiography
    Chaussat, C
    Chabbal, J
    Ducourant, T
    Moy, JP
    Spinnler, V
    Spahn, M
    Hahm, G
    RADIOLOGY, 1997, 205 : 102 - 102
  • [30] Erratum to: Clinical evaluation of digital radiography based on a large-area cesium iodide-amorphous silicon flat-panel detector compared with screen-film radiography for skeletal system and abdomen
    Terue Okamura
    Saori Tanaka
    Koichi Koyama
    Norifumi Nishida
    Hideo Daikokuya
    Toshiyuki Matsuoka
    Kenji Kishimoto
    Masakatsu Hatagawa
    Hiroaki Kudoh
    Ryusaku Yamada
    European Radiology, 2002, 12 (4) : 951 - 951