An Experimental Comparison of Flat-Panel Detector Performance for Direct and Indirect Systems (Initial Experiences and Physical Evaluation)

被引:0
|
作者
Tsutomu Gomi
Kichirou Koshida
Tosiaki Miyati
Jun Miyagawa
Hiroshi Hirano
机构
[1] Shinshu University Hospital,Department of Radiology
[2] Kanazawa University,Graduate School of Medicine
来源
关键词
Flat-panel detector; image quality; modulation transfer function (MTF); Wiener spectrum (WS); noise equivalent quanta (NEQ);
D O I
暂无
中图分类号
学科分类号
摘要
The purpose of this work was to compare direct and indirect detectors in terms of their system linearity, presampled modulation transfer function (MTF), Wiener spectrum (WS), noise equivalent quanta (NEQ), and power spectrum. Measurements were made on two flat-panel detectors, GE Revolution XR/d (indirect) and Shimadzu Safire (direct) radiographic techniques. The system linearity of the systems was measured using a time-scale method. The MTF of the systems was measured using an edge method. The WS of the systems was determined for a variable range of exposure levels by two-dimensional Fourier analysis. The NEQ was assessed from the measured MTF, WS, and estimated ideal signal-to-noise ratios. Power spectrum analyzed the chest phantom within artificial lesions. System linearity was excellent for the direct systems. For the direct system, the MTF was found to be significantly higher than that for the indirect systems. For the direct system, the WS was relatively uniform across all frequencies. In comparison, the indirect system exhibited a drop in the WS at high frequencies. At lower frequencies, the NEQ for the indirect system was noticeably higher than for the direct system. Power spectrum for the direct system was relatively flat and similar to that for white noise. The indirect system exhibited significant reduction at high spatial frequencies. In general, the direct systems exhibit improved image quality over indirect systems at comparable exposure dose.
引用
收藏
相关论文
共 50 条
  • [1] An experimental comparison of flat-panel detector performance for direct and indirect systems (initial experiences and physical evaluation)
    Gomi, Tsutomu
    Koshida, Kichirou
    Miyati, Tosiaki
    Miyagawa, Jun
    Hirano, Hiroshi
    JOURNAL OF DIGITAL IMAGING, 2006, 19 (04) : 362 - 370
  • [2] A performance comparison of direct- and indirect-detection flat-panel imagers
    Partridge, M
    Hesse, BM
    Müller, L
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2002, 484 (1-3): : 351 - 363
  • [3] Indirect flat-panel detector with avalanche gain
    Zhao, W
    Hunt, DC
    Tanioka, K
    Rowlands, JA
    MEDICAL IMAGING 2004: PHYSICS OF MEDICAL IMAGING, PTS 1 AND 2, 2004, 5368 : 150 - 161
  • [4] Imaging performance of a direct digital flat-panel radiographic detector
    Kengyelics, SM
    Davies, AG
    Launders, JH
    Cowen, AR
    Richardson, DL
    Wilson, P
    RADIOLOGY, 1998, 209P : 358 - 358
  • [5] An experimental comparison of detector performance for direct and indirect digital radiography systems
    Samei, E
    Flynn, MJ
    MEDICAL PHYSICS, 2003, 30 (04) : 608 - 622
  • [6] Experimental evaluation of a portable indirect flat-panel detector for the pediatric chest: Comparison with storage phosphor radiography at different exposures by using a chest phantom
    Rapp-Bernhardt, U
    Bernhardt, TM
    Lenzen, H
    Esseling, R
    Roehl, FW
    Schiborr, M
    Theobold-Hormann, I
    Heindel, W
    RADIOLOGY, 2005, 237 (02) : 485 - 491
  • [7] Challenges in Evaluating Flat-Panel Detector Fluoroscopy Systems
    Mahesh, Mahadevappa
    JOURNAL OF THE AMERICAN COLLEGE OF RADIOLOGY, 2013, 10 (03) : 223 - 224
  • [8] Initial performance evaluation of an indirect-detection, active matrix flat-panel imager (AMFPI) prototype for megavoltage imaging
    Antonuk, LE
    El-Mohri, Y
    Huang, WD
    Jee, KW
    Siewerdsen, JH
    Maolinbay, M
    Scarpine, VE
    Sandler, H
    Yorkston, J
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1998, 42 (02): : 437 - 454
  • [9] Experimental in vitro study to evaluate a flat-panel detector system
    Meier, S
    Mildenberger, P
    Oberholzer, K
    Krummenauer, F
    Thelen, M
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2004, 176 (06): : 875 - 879
  • [10] The amorphous selenium based flat-panel detector. Clinical experiences
    Schmidt, EL
    Herbig, W
    RADIOLOGE, 2003, 43 (05): : 374 - 378