The effect of suture anchor design and orientation on suture abrasion: An in vitro study

被引:64
|
作者
Bardana, DD
Burks, RT
West, JR
Greis, PE
机构
[1] Univ Utah, Dept Orthoped, Salt Lake City, UT 84132 USA
[2] Kingston Gen Hosp, Dept Surg, Kingston, ON K7L 2V7, Canada
[3] Univ Cincinnati, Noyes Giannestras Biomech Lab, Dept Biomed Engn, Cincinnati, OH USA
关键词
sutures; equipment failure; suture anchor; abrasion; cyclic loading; arthroscopy;
D O I
10.1053/jars.2003.50032
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Purpose: To evaluate the effects of suture anchor design and orientation on suture abrasion in a cyclic model. Type of Study: In vitro. Methods: Biomechanical studies have shown suture breakage to be a predominant mode of failure in a suture anchor repair construct. It is possible that suture abrasion during knot tying or in vivo cyclic loading may contribute to early failure. This study specifically investigates suture abrasion caused by 17 commonly used suture anchors and demonstrates the effects of suture anchor angulation and rotation on suture abrasion. To eliminate target tissue as a source of failure, all anchors were implanted into a solid block of sawbones material and tested with No. 2 Ethibond Excel sutures (Ethicon, Somerville, NJ). The testing model focused on 3 variables: suture anchor type, suture pull angle (SA) and angle of anchor rotation (RA). Abrasion testing was then performed on a servohydraulic materials testing system by continually cycling the suture back and forth through each anchor with an excursion of 4 cm at a rate of 0.5 Hz under a load of 10 N until suture failure occurred. Results: Sutures performed significantly better when cycled in line with the anchor at 0degrees SA with 0degrees RA than they did at 45degrees SA with 0degrees RA or 45degrees SA with 90degrees RA. We found no significant difference between anchors tested at 45degrees SA with 0degrees RA and 45degrees SA with 90degrees RA. For tests performed using metallic suture anchors, all constructs failed by fraying of the suture. Constructs using biopolymer anchors and nonabsorbable polymeric anchors experienced a mixture of suture and anchor eyelet failures. Conclusions: In addition to the statistically significant detrimental effects of suture anchor angulation and rotation on suture abrasion, suture anchor eyelet design may also influence suture abrasion. Surgeons should be aware of the effects of anchor angulation, suture position in the eyelet, and design and composition of the eyelet to maximize the durability of the construct.
引用
收藏
页码:274 / 281
页数:8
相关论文
共 50 条
  • [41] Evaluation of BioCorkscrew and Bioknotless RC suture anchor rotator cuff repair fixation: an in vitro biomechanical study
    Ammon, Jennifer Tucker
    Nyland, John
    Chang, Haw Chong
    Burden, Robert
    Caborn, David N. M.
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2007, 15 (11) : 1375 - 1381
  • [42] Using a modified recycled corkscrew suture anchor to pass a suture under the coracoid base
    Chuaychoosakoon, Chaiwat
    Klabklay, Prapakorn
    Maliwankul, Korakot
    INTERNATIONAL JOURNAL OF SURGERY CASE REPORTS, 2023, 106
  • [43] Biomechanical comparison of screw-in suture anchor–suture combinations used for Bankart repair
    Brad S. Sparks
    John Nyland
    Akbar Nawab
    Ethan Blackburn
    Ryan Krupp
    David N. M. Caborn
    Archives of Orthopaedic and Trauma Surgery, 2010, 130 : 321 - 327
  • [44] Anatomic Knot Suture Anchor Versus Knotless Suture Anchor Technique for Anterior Talofibular Ligament Repair: A Biomechanical Comparison
    Li, Hong
    Xu, Hanlin
    Hua, Yinghui
    Chen, Wenbo
    Li, Hongyun
    Chen, Shiyi
    ORTHOPAEDIC JOURNAL OF SPORTS MEDICINE, 2020, 8 (01)
  • [45] Patellar Sleeve Avulsion Fracture Repair: Suture Anchor Technique With Suture Cerclage Augmentation
    Nowell, Jared A.
    Niu, Emily L.
    ARTHROSCOPY TECHNIQUES, 2023, 12 (12): : e2197 - e2202
  • [46] Biomechanical Analysis of All-Suture Suture Anchor Fixation Compared With Conventional Suture Anchors and Interference Screws for Biceps Tenodesis
    Frank, Rachel M.
    Bernardoni, Eamon D.
    Veera, Shreya S.
    Waterman, Brian R.
    Griffin, Justin W.
    Shewman, Elizabeth F.
    Cole, Brian J.
    Romeo, Anthony A.
    Verma, Nikhil N.
    ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2019, 35 (06): : 1760 - 1768
  • [47] Options for glenoid labral suture anchor fixation
    Rudzki, JR
    Purcell, DB
    Wright, RW
    OPERATIVE TECHNIQUES IN SPORTS MEDICINE, 2004, 12 (04) : 225 - 231
  • [48] Suture Anchor Insertion Angle and the Deadman Theory
    Burkhart, Stephen S.
    ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2009, 25 (12): : 1365 - 1365
  • [49] Refixation of sternoclavicular luxation with a suture anchor system
    Lehmann, W.
    Laskowski, J.
    Grossterlinden, L.
    Rueger, J. M.
    UNFALLCHIRURG, 2010, 113 (05): : 418 - 421
  • [50] All-suture Anchor Status quo
    Klatte, T. O.
    Ntalos, D.
    Frosch, K. -H.
    ARTHROSKOPIE, 2019, 32 (06) : 439 - 444