The effect of suture anchor design and orientation on suture abrasion: An in vitro study

被引:64
|
作者
Bardana, DD
Burks, RT
West, JR
Greis, PE
机构
[1] Univ Utah, Dept Orthoped, Salt Lake City, UT 84132 USA
[2] Kingston Gen Hosp, Dept Surg, Kingston, ON K7L 2V7, Canada
[3] Univ Cincinnati, Noyes Giannestras Biomech Lab, Dept Biomed Engn, Cincinnati, OH USA
关键词
sutures; equipment failure; suture anchor; abrasion; cyclic loading; arthroscopy;
D O I
10.1053/jars.2003.50032
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Purpose: To evaluate the effects of suture anchor design and orientation on suture abrasion in a cyclic model. Type of Study: In vitro. Methods: Biomechanical studies have shown suture breakage to be a predominant mode of failure in a suture anchor repair construct. It is possible that suture abrasion during knot tying or in vivo cyclic loading may contribute to early failure. This study specifically investigates suture abrasion caused by 17 commonly used suture anchors and demonstrates the effects of suture anchor angulation and rotation on suture abrasion. To eliminate target tissue as a source of failure, all anchors were implanted into a solid block of sawbones material and tested with No. 2 Ethibond Excel sutures (Ethicon, Somerville, NJ). The testing model focused on 3 variables: suture anchor type, suture pull angle (SA) and angle of anchor rotation (RA). Abrasion testing was then performed on a servohydraulic materials testing system by continually cycling the suture back and forth through each anchor with an excursion of 4 cm at a rate of 0.5 Hz under a load of 10 N until suture failure occurred. Results: Sutures performed significantly better when cycled in line with the anchor at 0degrees SA with 0degrees RA than they did at 45degrees SA with 0degrees RA or 45degrees SA with 90degrees RA. We found no significant difference between anchors tested at 45degrees SA with 0degrees RA and 45degrees SA with 90degrees RA. For tests performed using metallic suture anchors, all constructs failed by fraying of the suture. Constructs using biopolymer anchors and nonabsorbable polymeric anchors experienced a mixture of suture and anchor eyelet failures. Conclusions: In addition to the statistically significant detrimental effects of suture anchor angulation and rotation on suture abrasion, suture anchor eyelet design may also influence suture abrasion. Surgeons should be aware of the effects of anchor angulation, suture position in the eyelet, and design and composition of the eyelet to maximize the durability of the construct.
引用
收藏
页码:274 / 281
页数:8
相关论文
共 50 条
  • [31] PERCUTANEOUS ENTEROSTOMY WITH THE COPE SUTURE ANCHOR
    COLEMAN, CC
    COONS, HG
    COPE, C
    DERAUF, BJ
    KRENZEL, C
    EPSTEIN, DH
    SCHLAM, BW
    CASTANEDA, F
    HOUGH, JP
    MORADIAN, GP
    RADIOLOGY, 1990, 174 (03) : 889 - 891
  • [32] Knotless Suture Anchor With Suture Tape Quadriceps Tendon Repair Is Biomechanically Superior to Transosseous and Traditional Suture Anchor-Based Repairs in a Cadaveric Model
    Kindya, Michael C.
    Konicek, John
    Rizzi, Angelo
    Komatsu, David E.
    Paci, James M.
    ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2017, 33 (01): : 190 - 198
  • [33] The suture-weave technique: A method of reloading a deployed unloaded suture anchor
    Brady, Paul. C.
    Burkhart, Stephen S.
    ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2006, 22 (07): : 800A - U81
  • [34] Comparison Between Suture Anchor and Transosseous Suture for the Modified-Brostrom Procedure
    Cho, Byung-Ki
    Kim, Yong-Min
    Kim, Dong-Soo
    Choi, Eui-Sung
    Shon, Hyun-Chul
    Park, Kyoung-Jin
    FOOT & ANKLE INTERNATIONAL, 2012, 33 (06) : 462 - 468
  • [35] Design of a suture anchor based on the superelasticity of the Ni-Ti alloy
    Puértolas, JA
    Pérez-García, JM
    Juan, E
    Ríos, R
    BIO-MEDICAL MATERIALS AND ENGINEERING, 2002, 12 (03) : 283 - 289
  • [36] Arthroscopic repair of rotator cuff injury with bioabsorbable suture anchor vs. all-suture anchor: a non-inferiority study
    Di Gennaro, Stefano
    Lecce, Domenico
    Tarantino, Alessio
    De Cupis, Mauro
    Bassetti, Erica
    Scarnera, Pierpaolo
    Ciminello, Enrico
    Calvisi, Vittorio
    BMC MUSCULOSKELETAL DISORDERS, 2022, 23 (01)
  • [37] Arthroscopic repair of rotator cuff injury with bioabsorbable suture anchor vs. all-suture anchor: a non-inferiority study
    Stefano Di Gennaro
    Domenico Lecce
    Alessio Tarantino
    Mauro De Cupis
    Erica Bassetti
    Pierpaolo Scarnera
    Enrico Ciminello
    Vittorio Calvisi
    BMC Musculoskeletal Disorders, 23
  • [38] Transosseous suture versus suture anchor fixation for inferior pole fractures of the patella in osteoporotic bone: a biomechanical study
    Jana Seggewiss
    Luis Fernando Nicolini
    Philipp Lichte
    Johannes Greven
    Marx Ribeiro
    Andreas Prescher
    Roman Michalik
    Christian Herren
    Philipp Kobbe
    Frank Hildebrand
    Miguel Pishnamaz
    European Journal of Medical Research, 27
  • [39] Transosseous suture versus suture anchor fixation for inferior pole fractures of the patella in osteoporotic bone: a biomechanical study
    Seggewiss, Jana
    Nicolini, Luis Fernando
    Lichte, Philipp
    Greven, Johannes
    Ribeiro, Marx
    Prescher, Andreas
    Michalik, Roman
    Herren, Christian
    Kobbe, Philipp
    Hildebrand, Frank
    Pishnamaz, Miguel
    EUROPEAN JOURNAL OF MEDICAL RESEARCH, 2022, 27 (01)
  • [40] Evaluation of BioCorkscrew and Bioknotless RC suture anchor rotator cuff repair fixation: an in vitro biomechanical study
    Jennifer Tucker Ammon
    John Nyland
    Haw Chong Chang
    Robert Burden
    David N. M. Caborn
    Knee Surgery, Sports Traumatology, Arthroscopy, 2007, 15 : 1375 - 1381