Reducing Abdominal CT Radiation Dose With Adaptive Statistical Iterative Reconstruction Technique

被引:401
|
作者
Prakash, Priyanka [1 ,2 ]
Kalra, Mannudeep K. [1 ,2 ]
Kambadakone, Avinash K. [1 ,2 ]
Pien, Homer [1 ,2 ]
Hsieh, Jiang [3 ]
Blake, Michael A. [1 ,2 ]
Sahani, Dushyant V. [1 ,2 ]
机构
[1] Massachusetts Gen Hosp, Dept Radiol, Boston, MA 02114 USA
[2] Harvard Univ, Sch Med, Boston, MA 02114 USA
[3] GE Healthcare, Waukesha, WI USA
关键词
abdominal CT; interative reconstruction; ASIR; radiation dose; COMPUTED-TOMOGRAPHY; IMAGE-QUALITY; ROW CT; REDUCTION; ANGIOGRAPHY; NOISE;
D O I
10.1097/RLI.ob013e3181dzfeec
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To assess radiation dose reduction for abdominal computed tomography (CT) examinations with adaptive statistical iterative reconstruction (ASIR) technique. Materials and Methods: With institutional review board approval, retrospective review of weight adapted abdominal CT exams were performed in 156 consecutive patients with ASIR and in 66 patients with filtered back projection (FBP) on a 64-slice MDCT. Patients were categorized into 3 groups of < 60 kg (n = 42), 61 to 90 kg (n = 100), and >= 91 kg (n = 80) for weight-based adjustment of automatic exposure control technique. Remaining scan parameters were held constant at 1.375:1 pitch, 120 kVp, 55 mm table feed per rotation, 5 mm section thickness. Two radiologists reviewed all CT examinations for image noise and diagnostic acceptability. CT dose index volume, and dose length product were recorded. Image noise and transverse abdominal diameter were measured in all patients. Data were analyzed using analysis of variance. Results: ASIR allowed for an overall average decrease of 25.1% in CT dose index volume compared with the FBP technique (ASIR, 11.9 +/- 3.6 mGy; FBP, 15.9 +/- 4.3 mGy) (P < 0.0001). In each of the 3 weight categories, CT examinations reconstructed with ASIR technique were associated with significantly lower radiation dose compared with FBP technique (P < 0.0001). There was also significantly less objective image noise with ASIR (6.9 +/- 2.2) than with FBP (9.5 +/- 2.0) (P < 0.0001). For the subjective analysis, all ASIR and FBP reconstructed abdominal CTs had optimal or less noise. However, 9% of FBP and 3.8% of ASIR reconstructed CT examinations were diagnostically unacceptable because of the presence of artifacts. Use of ASIR reconstruction kernel results in a blotchy pixilated appearance in 39% of CT sans which however, was mild and did not affect the diagnostic acceptability of images. The critical reproduction of visually sharp anatomic structures was preserved in all but one ASIR 40% reconstructed CT examination. Conclusion: ASIR technique allows radiation dose reduction for abdominal CT examinations whereas improving image noise compared with the FBP technique.
引用
收藏
页码:202 / 210
页数:9
相关论文
共 50 条
  • [21] Model-Based Iterative Reconstruction Versus Adaptive Statistical Iterative Reconstruction in Low-Dose Abdominal CT for Urolithiasis
    Botsikas, Diomidis
    Stefanelli, Salvatore
    Boudabbous, Sana
    Toso, Seema
    Becker, Christoph D.
    Montet, Xavier
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2014, 203 (02) : 336 - 340
  • [22] New scanning technique using Adaptive Statistical Iterative Reconstruction (ASIR) significantly reduced the radiation dose of cardiac CT
    Tumur, Odgerel
    Soon, Kean
    Brown, Fraser
    Mykytowycz, Marcus
    JOURNAL OF MEDICAL IMAGING AND RADIATION ONCOLOGY, 2013, 57 (03) : 292 - 296
  • [23] Radiation dose reduction with the adaptive statistical iterative reconstruction (ASIR) technique for chest CT in children: An intra-individual comparison
    Lee, Seung Hyun
    Kim, Myung-Joon
    Yoon, Choon-Sik
    Lee, Mi-Jung
    EUROPEAN JOURNAL OF RADIOLOGY, 2012, 81 (09) : E938 - E943
  • [24] Low-Dose CT With the Adaptive Statistical Iterative Reconstruction V Technique in Abdominal Organ Injury: Comparison With Routine-Dose CT With Filtered Back Projection
    Lee, Nam Kyung
    Kim, Suk
    Hong, Seung BaeK
    Kim, Tae Un
    Ryu, Hwaseong
    Lee, Ji Won
    Kim, Jin You
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2019, 213 (03) : 659 - 666
  • [25] Lowering the Dose in Head CT Using Adaptive Statistical Iterative Reconstruction
    Kilic, K.
    Erbas, G.
    Guryildirim, M.
    Arac, M.
    Ilgit, E.
    Coskun, B.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2011, 32 (09) : 1578 - 1582
  • [26] Radiation dose reduction in soft tissue neck CT using adaptive statistical iterative reconstruction (ASIR)
    Vachha, Behroze
    Brodoefel, Harald
    Wilcox, Carol
    Hackney, David B.
    Moonis, Gul
    EUROPEAN JOURNAL OF RADIOLOGY, 2013, 82 (12) : 2222 - 2226
  • [27] Cranial CT with Adaptive Statistical Iterative Reconstruction: Improved Image Quality with Concomitant Radiation Dose Reduction
    Rapalino, O.
    Kamalian, Shervin
    Kamalian, Shahmir
    Payabvash, S.
    Souza, L. C. S.
    Zhang, D.
    Mukta, J.
    Sahani, D. V.
    Lev, M. H.
    Pomerantz, S. R.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2012, 33 (04) : 609 - 615
  • [28] Impact of the adaptive statistical iterative reconstruction technique on image quality in ultra-low-dose CT
    Xu, Yan
    He, Wen
    Chen, Hui
    Hu, Zhihai
    Li, Juan
    Zhang, Tingting
    CLINICAL RADIOLOGY, 2013, 68 (09) : 902 - 908
  • [29] MDCT Arthrography of the Hip: Value of the Adaptive Statistical Iterative Reconstruction Technique and Potential for Radiation Dose Reduction
    Tobalem, Frank
    Dugert, Eric
    Verdun, Francis R.
    Dunet, Vincent
    Ott, Julien G.
    Rudiger, Hannes A.
    Cherix, Stephane
    Meuli, Reto
    Becce, Fabio
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2014, 203 (06) : W665 - W673
  • [30] Adaptive statistical iterative reconstruction: reducing dose while preserving image quality in the pediatric head CT examination
    Colin D. McKnight
    Kuanwong Watcharotone
    Mohannad Ibrahim
    Emmanuel Christodoulou
    Aaron H. Baer
    Hemant A. Parmar
    Pediatric Radiology, 2014, 44 : 997 - 1003