Radiation dose reduction with the adaptive statistical iterative reconstruction (ASIR) technique for chest CT in children: An intra-individual comparison

被引:38
|
作者
Lee, Seung Hyun [1 ,2 ]
Kim, Myung-Joon [1 ,2 ]
Yoon, Choon-Sik [3 ]
Lee, Mi-Jung [1 ,2 ]
机构
[1] Yonsei Univ, Coll Med, Dept Radiol, Severance Childrens Hosp, Seoul 120752, South Korea
[2] Yonsei Univ, Coll Med, Res Inst Radiol Sci, Severance Childrens Hosp, Seoul 120752, South Korea
[3] Yonsei Univ, Coll Med, Gangnam Severance Hosp, Dept Radiol, Seoul 120752, South Korea
关键词
Adaptive statistical iterative reconstruction; Image quality; Radiation dose; Reconstruction algorithm; CT; TUBE CURRENT MODULATION; IMPROVED IMAGE QUALITY; COMPUTED-TOMOGRAPHY; FEASIBILITY; EXPERIENCE; ALGORITHM; EXPOSURE;
D O I
10.1016/j.ejrad.2012.06.013
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objective: To retrospectively compare radiation dose and image quality of pediatric chest CT using a routine dose protocol reconstructed with filtered back projection (FBP) (the Routine study) and a low-dose protocol with 50% adaptive statistical iterative reconstruction (ASIR) (the ASIR study). Materials and methods: We retrospectively reviewed chest CT performed in pediatric patients who underwent both the Routine study and the ASIR study on different days between January 2010 and August 2011. Volume CT dose indices (CTDIvol), dose length products (DLP), and effective doses were obtained to estimate radiation dose. The image quality was evaluated objectively as noise measured in the descending aorta and paraspinal muscle, and subjectively by three radiologists for noise, sharpness, artifacts, and diagnostic acceptability using a four-point scale. The paired Student's t-test and the Wilcoxon signed-rank test were used for statistical analysis. Results: Twenty-six patients (M: F = 13: 13, mean age 11.7) were enrolled. The ASIR studies showed 60.3%, 56.2%, and 55.2% reductions in CTDIvol (from 18.73 to 7.43 mGy, P < 0.001), DLP (from 307.42 to 134.51 mGy x cm, P < 0.001), and effective dose (from 4.12 to 1.84 mSv, P < 0.001), respectively, compared with the Routine studies. The objective noise was higher in the paraspinal muscle of the ASIR studies (20.81 vs. 16.67, P = 0.004), but was not different in the aorta (18.23 vs. 18.72, P = 0.726). The subjective image quality demonstrated no difference between the two studies. Conclusion: A low-dose protocol with 50% ASIR allows radiation dose reduction in pediatric chest CT by more than 55% while maintaining image quality. (C) 2012 Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:E938 / E943
页数:6
相关论文
共 50 条
  • [1] Model-based iterative reconstruction technique for radiation dose reduction in chest CT: comparison with the adaptive statistical iterative reconstruction technique
    Masaki Katsura
    Izuru Matsuda
    Masaaki Akahane
    Jiro Sato
    Hiroyuki Akai
    Koichiro Yasaka
    Akira Kunimatsu
    Kuni Ohtomo
    European Radiology, 2012, 22 : 1613 - 1623
  • [2] Model-based iterative reconstruction technique for radiation dose reduction in chest CT: comparison with the adaptive statistical iterative reconstruction technique
    Katsura, Masaki
    Matsuda, Izuru
    Akahane, Masaaki
    Sato, Jiro
    Akai, Hiroyuki
    Yasaka, Koichiro
    Kunimatsu, Akira
    Ohtomo, Kuni
    EUROPEAN RADIOLOGY, 2012, 22 (08) : 1613 - 1623
  • [3] Adaptive Statistical Iterative Reconstruction Technique for Radiation Dose Reduction in Chest CT: A Pilot Study
    Singh, Sarabjeet
    Kalra, Mannudeep K.
    Gilman, Matthew D.
    Hsieh, Jiang
    Pien, Homer H.
    Digumarthy, Subba R.
    Shepard, Jo-Anne O.
    RADIOLOGY, 2011, 259 (02) : 565 - 573
  • [4] The adaptive statistical iterative reconstruction-V technique for radiation dose reduction in abdominal CT: comparison with the adaptive statistical iterative reconstruction technique
    Kwon, Heejin
    Cho, Jinhan
    Oh, Jongyeong
    Kim, Dongwon
    Cho, Junghyun
    Kim, Sanghyun
    Lee, Sangyun
    Lee, Jihyun
    BRITISH JOURNAL OF RADIOLOGY, 2015, 88 (1054):
  • [5] Radiation dose reduction in soft tissue neck CT using adaptive statistical iterative reconstruction (ASIR)
    Vachha, Behroze
    Brodoefel, Harald
    Wilcox, Carol
    Hackney, David B.
    Moonis, Gul
    EUROPEAN JOURNAL OF RADIOLOGY, 2013, 82 (12) : 2222 - 2226
  • [6] Radiation dose reduction for CT assessment of urolithiasis using iterative reconstruction: A prospective intra-individual study
    Annemarie M. den Harder
    Martin J. Willemink
    Pieter J. van Doormaal
    Frank J. Wessels
    M. T. W. T. Lock
    Arnold M. R. Schilham
    Ricardo P. J. Budde
    Tim Leiner
    Pim A. de Jong
    European Radiology, 2018, 28 : 143 - 150
  • [7] Radiation dose reduction for CT assessment of urolithiasis using iterative reconstruction: A prospective intra-individual study
    den Harder, Annemarie M.
    Willemink, Martin J.
    van Doormaal, Pieter J.
    Wessels, Frank J.
    Lock, M. T. W. T.
    Schilham, Arnold M. R.
    Budde, Ricardo P. J.
    Leiner, Tim
    de Jong, Pim A.
    EUROPEAN RADIOLOGY, 2018, 28 (01) : 143 - 150
  • [8] Radiation dose reduction in CT with adaptive statistical iterative reconstruction (ASIR) for patients with bronchial carcinoma and intrapulmonary metastases
    Schaefer, M. -L.
    Luedemann, L.
    Boening, G.
    Kahn, J.
    Fuchs, S.
    Hamm, B.
    Streitparth, F.
    CLINICAL RADIOLOGY, 2016, 71 (05) : 442 - 449
  • [9] The adaptive statistical iterative reconstruction-V technique for radiation dose reduction in abdominal CT: comparison with the adaptive statistical iterative reconstruction technique (vol 88, 20150463, 2015)
    Kwon, H.
    Cho, J.
    Oh, J.
    Kim, D.
    Cho, J.
    Kim, S.
    BRITISH JOURNAL OF RADIOLOGY, 2016, 89 (1058):
  • [10] New scanning technique using Adaptive Statistical Iterative Reconstruction (ASIR) significantly reduced the radiation dose of cardiac CT
    Tumur, Odgerel
    Soon, Kean
    Brown, Fraser
    Mykytowycz, Marcus
    JOURNAL OF MEDICAL IMAGING AND RADIATION ONCOLOGY, 2013, 57 (03) : 292 - 296