Radiation dose reduction with the adaptive statistical iterative reconstruction (ASIR) technique for chest CT in children: An intra-individual comparison

被引:38
|
作者
Lee, Seung Hyun [1 ,2 ]
Kim, Myung-Joon [1 ,2 ]
Yoon, Choon-Sik [3 ]
Lee, Mi-Jung [1 ,2 ]
机构
[1] Yonsei Univ, Coll Med, Dept Radiol, Severance Childrens Hosp, Seoul 120752, South Korea
[2] Yonsei Univ, Coll Med, Res Inst Radiol Sci, Severance Childrens Hosp, Seoul 120752, South Korea
[3] Yonsei Univ, Coll Med, Gangnam Severance Hosp, Dept Radiol, Seoul 120752, South Korea
关键词
Adaptive statistical iterative reconstruction; Image quality; Radiation dose; Reconstruction algorithm; CT; TUBE CURRENT MODULATION; IMPROVED IMAGE QUALITY; COMPUTED-TOMOGRAPHY; FEASIBILITY; EXPERIENCE; ALGORITHM; EXPOSURE;
D O I
10.1016/j.ejrad.2012.06.013
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objective: To retrospectively compare radiation dose and image quality of pediatric chest CT using a routine dose protocol reconstructed with filtered back projection (FBP) (the Routine study) and a low-dose protocol with 50% adaptive statistical iterative reconstruction (ASIR) (the ASIR study). Materials and methods: We retrospectively reviewed chest CT performed in pediatric patients who underwent both the Routine study and the ASIR study on different days between January 2010 and August 2011. Volume CT dose indices (CTDIvol), dose length products (DLP), and effective doses were obtained to estimate radiation dose. The image quality was evaluated objectively as noise measured in the descending aorta and paraspinal muscle, and subjectively by three radiologists for noise, sharpness, artifacts, and diagnostic acceptability using a four-point scale. The paired Student's t-test and the Wilcoxon signed-rank test were used for statistical analysis. Results: Twenty-six patients (M: F = 13: 13, mean age 11.7) were enrolled. The ASIR studies showed 60.3%, 56.2%, and 55.2% reductions in CTDIvol (from 18.73 to 7.43 mGy, P < 0.001), DLP (from 307.42 to 134.51 mGy x cm, P < 0.001), and effective dose (from 4.12 to 1.84 mSv, P < 0.001), respectively, compared with the Routine studies. The objective noise was higher in the paraspinal muscle of the ASIR studies (20.81 vs. 16.67, P = 0.004), but was not different in the aorta (18.23 vs. 18.72, P = 0.726). The subjective image quality demonstrated no difference between the two studies. Conclusion: A low-dose protocol with 50% ASIR allows radiation dose reduction in pediatric chest CT by more than 55% while maintaining image quality. (C) 2012 Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:E938 / E943
页数:6
相关论文
共 50 条
  • [21] Model-Based Iterative Reconstruction Technique for Ultralow-Dose Chest CT Comparison of Pulmonary Nodule Detectability With the Adaptive Statistical Iterative Reconstruction Technique
    Katsura, Masaki
    Matsuda, Izuru
    Akahane, Masaaki
    Yasaka, Koichiro
    Hanaoka, Shohei
    Akai, Hiroyuki
    Sato, Jiro
    Kunimatsu, Akira
    Ohtomo, Kuni
    INVESTIGATIVE RADIOLOGY, 2013, 48 (04) : 206 - 212
  • [22] The use of adaptive statistical iterative reconstruction (ASiR) technique in evaluation of patients with cervical spine trauma: impact on radiation dose reduction and image quality
    Patro, Satya N.
    Chakraborty, Santanu
    Sheikh, Adnan
    BRITISH JOURNAL OF RADIOLOGY, 2016, 89 (1060):
  • [23] Dose reduction in chest CT: Comparison of the adaptive iterative dose reduction 3D, adaptive iterative dose reduction, and filtered back projection reconstruction techniques
    Yamada, Yoshitake
    Jinzaki, Masahiro
    Hosokawa, Takahiro
    Tanami, Yutaka
    Sugiura, Hiroaki
    Abe, Takayuki
    Kuribayashi, Sachio
    EUROPEAN JOURNAL OF RADIOLOGY, 2012, 81 (12) : 4185 - 4195
  • [24] Evaluation of pulmonary nodules and infection on chest CT with radiation dose equivalent to chest radiography: Prospective intra-individual comparison study to standard dose CT
    Martini, K.
    Barth, B. K.
    Nguyen-Kim, T. D. L.
    Baumueller, S.
    Alkadhi, H.
    Frauenfelder, T.
    EUROPEAN JOURNAL OF RADIOLOGY, 2016, 85 (02) : 360 - 365
  • [25] A Prospective Evaluation of Dose Reduction and Image Quality in Chest CT Using Adaptive Statistical Iterative Reconstruction
    Leipsic, Jonathon
    Nguyen, Giang
    Brown, Jaqueline
    Sin, Don
    Mayo, John R.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2010, 195 (05) : 1095 - 1099
  • [26] Dose reduction for chest CT: comparison of two iterative reconstruction techniques
    Pourjabbar, Sarvenaz
    Singh, Sarabjeet
    Kulkarni, Naveen
    Muse, Victorine
    Digumarthy, Subba R.
    Deedar, Ranish
    Khawaja, Ali
    Padole, Atul
    Do, Synho
    Kalra, Mannudeep K.
    ACTA RADIOLOGICA, 2015, 56 (06) : 688 - 695
  • [27] Diffuse Lung Disease: CT of the Chest with Adaptive Statistical Iterative Reconstruction Technique
    Prakash, Priyanka
    Kalra, Mannudeep K.
    Ackman, Jeanne B.
    Digumarthy, Subba R.
    Hsieh, Jiang
    Do, Synho
    Shepard, Jo-Anne O.
    Gilman, Matthew D.
    RADIOLOGY, 2010, 256 (01) : 261 - 269
  • [28] Dose reduction with adaptive statistical iterative reconstruction for paediatric CT: phantom study and clinical experience on chest and abdomen CT
    Gay, F.
    Pavia, Y.
    Pierrat, N.
    Lasalle, S.
    Neuenschwander, S.
    Brisse, H. J.
    EUROPEAN RADIOLOGY, 2014, 24 (01) : 102 - 111
  • [29] Dose reduction with adaptive statistical iterative reconstruction for paediatric CT: phantom study and clinical experience on chest and abdomen CT
    F. Gay
    Y. Pavia
    N. Pierrat
    S. Lasalle
    S. Neuenschwander
    H. J. Brisse
    European Radiology, 2014, 24 : 102 - 111
  • [30] CT of the chest with model-based, fully iterative reconstruction: comparison with adaptive statistical iterative reconstruction
    Yasutaka Ichikawa
    Kakuya Kitagawa
    Naoki Nagasawa
    Shuichi Murashima
    Hajime Sakuma
    BMC Medical Imaging, 13