Radiation dose reduction with the adaptive statistical iterative reconstruction (ASIR) technique for chest CT in children: An intra-individual comparison

被引:38
|
作者
Lee, Seung Hyun [1 ,2 ]
Kim, Myung-Joon [1 ,2 ]
Yoon, Choon-Sik [3 ]
Lee, Mi-Jung [1 ,2 ]
机构
[1] Yonsei Univ, Coll Med, Dept Radiol, Severance Childrens Hosp, Seoul 120752, South Korea
[2] Yonsei Univ, Coll Med, Res Inst Radiol Sci, Severance Childrens Hosp, Seoul 120752, South Korea
[3] Yonsei Univ, Coll Med, Gangnam Severance Hosp, Dept Radiol, Seoul 120752, South Korea
关键词
Adaptive statistical iterative reconstruction; Image quality; Radiation dose; Reconstruction algorithm; CT; TUBE CURRENT MODULATION; IMPROVED IMAGE QUALITY; COMPUTED-TOMOGRAPHY; FEASIBILITY; EXPERIENCE; ALGORITHM; EXPOSURE;
D O I
10.1016/j.ejrad.2012.06.013
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objective: To retrospectively compare radiation dose and image quality of pediatric chest CT using a routine dose protocol reconstructed with filtered back projection (FBP) (the Routine study) and a low-dose protocol with 50% adaptive statistical iterative reconstruction (ASIR) (the ASIR study). Materials and methods: We retrospectively reviewed chest CT performed in pediatric patients who underwent both the Routine study and the ASIR study on different days between January 2010 and August 2011. Volume CT dose indices (CTDIvol), dose length products (DLP), and effective doses were obtained to estimate radiation dose. The image quality was evaluated objectively as noise measured in the descending aorta and paraspinal muscle, and subjectively by three radiologists for noise, sharpness, artifacts, and diagnostic acceptability using a four-point scale. The paired Student's t-test and the Wilcoxon signed-rank test were used for statistical analysis. Results: Twenty-six patients (M: F = 13: 13, mean age 11.7) were enrolled. The ASIR studies showed 60.3%, 56.2%, and 55.2% reductions in CTDIvol (from 18.73 to 7.43 mGy, P < 0.001), DLP (from 307.42 to 134.51 mGy x cm, P < 0.001), and effective dose (from 4.12 to 1.84 mSv, P < 0.001), respectively, compared with the Routine studies. The objective noise was higher in the paraspinal muscle of the ASIR studies (20.81 vs. 16.67, P = 0.004), but was not different in the aorta (18.23 vs. 18.72, P = 0.726). The subjective image quality demonstrated no difference between the two studies. Conclusion: A low-dose protocol with 50% ASIR allows radiation dose reduction in pediatric chest CT by more than 55% while maintaining image quality. (C) 2012 Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:E938 / E943
页数:6
相关论文
共 50 条
  • [31] CT of the chest with model-based, fully iterative reconstruction: comparison with adaptive statistical iterative reconstruction
    Ichikawa, Yasutaka
    Kitagawa, Kakuya
    Nagasawa, Naoki
    Murashima, Shuichi
    Sakuma, Hajime
    BMC MEDICAL IMAGING, 2013, 13
  • [32] Model-based iterative reconstruction in ultra-low-dose pediatric chest CT: comparison with adaptive statistical iterative reconstruction
    Kim, Hae Jin
    Yoo, So-Young
    Jeon, Tae Yeon
    Kim, Ji Hye
    CLINICAL IMAGING, 2016, 40 (05) : 1018 - 1022
  • [33] A usefulness evaluation of adaptive statistical iterative reconstruction (ASIR) in PET/CT to reduce radiation exposure of patients
    Ji, Hye-ryung
    Kim, Jung-yul
    Kang, Chun Goo
    Park, Min Soo
    Bahn, Yung Kag
    Lim, Han Sang
    Lee, Chang Ho
    JOURNAL OF NUCLEAR MEDICINE, 2012, 53
  • [34] Radiation Dose Reduction in Temporal Bone CT with Iterative Reconstruction Technique
    Niu, Y. T.
    Mehta, D.
    Zhang, Z. R.
    Zhang, Y. X.
    Liu, Y. F.
    Kang, T. L.
    Xian, J. F.
    Wang, Z. C.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2012, 33 (06) : 1020 - 1026
  • [35] Impact of the Adaptive Statistical Iterative Reconstruction Technique on Radiation Dose and Image Quality in Bone SPECT/CT
    Sibille, Louis
    Chambert, Benjamin
    Alonso, Sandrine
    Barrau, Corinne
    D'Estanque, Emmanuel
    Al Tabaa, Yassine
    Collombier, Laurent
    Demattei, Christophe
    Kotzki, Pierre-Olivier
    Boudousq, Vincent
    JOURNAL OF NUCLEAR MEDICINE, 2016, 57 (07) : 1091 - 1095
  • [36] Effects of adaptive statistical iterative reconstruction on radiation dose reduction and diagnostic accuracy of pediatric abdominal CT
    Sohi Bae
    Myung-Joon Kim
    Choon-Sik Yoon
    Dong Wook Kim
    Jung Hwa Hong
    Mi-Jung Lee
    Pediatric Radiology, 2014, 44 : 1541 - 1547
  • [37] Cranial CT with Adaptive Statistical Iterative Reconstruction: Improved Image Quality with Concomitant Radiation Dose Reduction
    Rapalino, O.
    Kamalian, Shervin
    Kamalian, Shahmir
    Payabvash, S.
    Souza, L. C. S.
    Zhang, D.
    Mukta, J.
    Sahani, D. V.
    Lev, M. H.
    Pomerantz, S. R.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2012, 33 (04) : 609 - 615
  • [38] Effects of adaptive statistical iterative reconstruction on radiation dose reduction and diagnostic accuracy of pediatric abdominal CT
    Bae, Sohi
    Kim, Myung-Joon
    Yoon, Choon-Sik
    Kim, Dong Wook
    Hong, Jung Hwa
    Lee, Mi-Jung
    PEDIATRIC RADIOLOGY, 2014, 44 (12) : 1541 - 1547
  • [39] MDCT Arthrography of the Hip: Value of the Adaptive Statistical Iterative Reconstruction Technique and Potential for Radiation Dose Reduction
    Tobalem, Frank
    Dugert, Eric
    Verdun, Francis R.
    Dunet, Vincent
    Ott, Julien G.
    Rudiger, Hannes A.
    Cherix, Stephane
    Meuli, Reto
    Becce, Fabio
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2014, 203 (06) : W665 - W673
  • [40] Image quality of iterative reconstruction in cranial CT imaging: comparison of model-based iterative reconstruction (MBIR) and adaptive statistical iterative reconstruction (ASiR)
    S. Notohamiprodjo
    Z. Deak
    F. Meurer
    F. Maertz
    F. G. Mueck
    L. L. Geyer
    S. Wirth
    European Radiology, 2015, 25 : 140 - 146