Model-based iterative reconstruction technique for radiation dose reduction in chest CT: comparison with the adaptive statistical iterative reconstruction technique

被引:247
|
作者
Katsura, Masaki [1 ]
Matsuda, Izuru [1 ]
Akahane, Masaaki [1 ]
Sato, Jiro [1 ]
Akai, Hiroyuki [1 ]
Yasaka, Koichiro [1 ]
Kunimatsu, Akira [1 ]
Ohtomo, Kuni [1 ]
机构
[1] Univ Tokyo, Grad Sch Med, Dept Radiol, Bunkyo Ku, Tokyo 1138655, Japan
关键词
Model-based iterative reconstruction; Adaptive statistical iterative reconstruction; Radiation dose reduction; Image noise; Spatial resolution; FILTERED BACK-PROJECTION; IMAGE QUALITY; COMPUTED-TOMOGRAPHY; EXPOSURE; KERNEL; NOISE;
D O I
10.1007/s00330-012-2452-z
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
To prospectively evaluate dose reduction and image quality characteristics of chest CT reconstructed with model-based iterative reconstruction (MBIR) compared with adaptive statistical iterative reconstruction (ASIR). One hundred patients underwent reference-dose and low-dose unenhanced chest CT with 64-row multidetector CT. Images were reconstructed with 50 % ASIR-filtered back projection blending (ASIR50) for reference-dose CT, and with ASIR50 and MBIR for low-dose CT. Two radiologists assessed the images in a blinded manner for subjective image noise, artefacts and diagnostic acceptability. Objective image noise was measured in the lung parenchyma. Data were analysed using the sign test and pair-wise Student's t-test. Compared with reference-dose CT, there was a 79.0 % decrease in dose-length product with low-dose CT. Low-dose MBIR images had significantly lower objective image noise (16.93 +/- 3.00) than low-dose ASIR (49.24 +/- 9.11, P < 0.01) and reference-dose ASIR images (24.93 +/- 4.65, P < 0.01). Low-dose MBIR images were all diagnostically acceptable. Unique features of low-dose MBIR images included motion artefacts and pixellated blotchy appearances, which did not adversely affect diagnostic acceptability. Diagnostically acceptable chest CT images acquired with nearly 80 % less radiation can be obtained using MBIR. MBIR shows greater potential than ASIR for providing diagnostically acceptable low-dose CT images without severely compromising image quality. aEuro cent Model-based iterative reconstruction (MBIR) creates high-quality low-dose CT images. aEuro cent MBIR significantly improves image noise and artefacts over adaptive statistical iterative techniques. aEuro cent MBIR shows greater potential than ASIR for diagnostically acceptable low-dose CT. aEuro cent The prolonged processing time of MBIR may currently limit its routine use in clinical practice.
引用
收藏
页码:1613 / 1623
页数:11
相关论文
共 50 条
  • [1] Model-based iterative reconstruction technique for radiation dose reduction in chest CT: comparison with the adaptive statistical iterative reconstruction technique
    Masaki Katsura
    Izuru Matsuda
    Masaaki Akahane
    Jiro Sato
    Hiroyuki Akai
    Koichiro Yasaka
    Akira Kunimatsu
    Kuni Ohtomo
    European Radiology, 2012, 22 : 1613 - 1623
  • [2] Model-based iterative reconstruction for reduction of radiation dose in abdominopelvic CT: comparison to adaptive statistical iterative reconstruction
    Yasaka, Koichiro
    Katsura, Masaki
    Akahane, Masaaki
    Sato, Jiro
    Matsuda, Izuru
    Ohtomo, Kuni
    SPRINGERPLUS, 2013, 2 : 1 - 9
  • [3] Model-Based Iterative Reconstruction Technique for Ultralow-Dose Chest CT Comparison of Pulmonary Nodule Detectability With the Adaptive Statistical Iterative Reconstruction Technique
    Katsura, Masaki
    Matsuda, Izuru
    Akahane, Masaaki
    Yasaka, Koichiro
    Hanaoka, Shohei
    Akai, Hiroyuki
    Sato, Jiro
    Kunimatsu, Akira
    Ohtomo, Kuni
    INVESTIGATIVE RADIOLOGY, 2013, 48 (04) : 206 - 212
  • [4] The adaptive statistical iterative reconstruction-V technique for radiation dose reduction in abdominal CT: comparison with the adaptive statistical iterative reconstruction technique
    Kwon, Heejin
    Cho, Jinhan
    Oh, Jongyeong
    Kim, Dongwon
    Cho, Junghyun
    Kim, Sanghyun
    Lee, Sangyun
    Lee, Jihyun
    BRITISH JOURNAL OF RADIOLOGY, 2015, 88 (1054):
  • [5] CT of the chest with model-based, fully iterative reconstruction: comparison with adaptive statistical iterative reconstruction
    Yasutaka Ichikawa
    Kakuya Kitagawa
    Naoki Nagasawa
    Shuichi Murashima
    Hajime Sakuma
    BMC Medical Imaging, 13
  • [6] CT of the chest with model-based, fully iterative reconstruction: comparison with adaptive statistical iterative reconstruction
    Ichikawa, Yasutaka
    Kitagawa, Kakuya
    Nagasawa, Naoki
    Murashima, Shuichi
    Sakuma, Hajime
    BMC MEDICAL IMAGING, 2013, 13
  • [7] Adaptive Statistical Iterative Reconstruction Technique for Radiation Dose Reduction in Chest CT: A Pilot Study
    Singh, Sarabjeet
    Kalra, Mannudeep K.
    Gilman, Matthew D.
    Hsieh, Jiang
    Pien, Homer H.
    Digumarthy, Subba R.
    Shepard, Jo-Anne O.
    RADIOLOGY, 2011, 259 (02) : 565 - 573
  • [8] Model-based iterative reconstruction in ultra-low-dose pediatric chest CT: comparison with adaptive statistical iterative reconstruction
    Kim, Hae Jin
    Yoo, So-Young
    Jeon, Tae Yeon
    Kim, Ji Hye
    CLINICAL IMAGING, 2016, 40 (05) : 1018 - 1022
  • [9] The adaptive statistical iterative reconstruction-V technique for radiation dose reduction in abdominal CT: comparison with the adaptive statistical iterative reconstruction technique (vol 88, 20150463, 2015)
    Kwon, H.
    Cho, J.
    Oh, J.
    Kim, D.
    Cho, J.
    Kim, S.
    BRITISH JOURNAL OF RADIOLOGY, 2016, 89 (1058):
  • [10] Radiation dose reduction with the adaptive statistical iterative reconstruction (ASIR) technique for chest CT in children: An intra-individual comparison
    Lee, Seung Hyun
    Kim, Myung-Joon
    Yoon, Choon-Sik
    Lee, Mi-Jung
    EUROPEAN JOURNAL OF RADIOLOGY, 2012, 81 (09) : E938 - E943