Model-based iterative reconstruction technique for radiation dose reduction in chest CT: comparison with the adaptive statistical iterative reconstruction technique

被引:247
|
作者
Katsura, Masaki [1 ]
Matsuda, Izuru [1 ]
Akahane, Masaaki [1 ]
Sato, Jiro [1 ]
Akai, Hiroyuki [1 ]
Yasaka, Koichiro [1 ]
Kunimatsu, Akira [1 ]
Ohtomo, Kuni [1 ]
机构
[1] Univ Tokyo, Grad Sch Med, Dept Radiol, Bunkyo Ku, Tokyo 1138655, Japan
关键词
Model-based iterative reconstruction; Adaptive statistical iterative reconstruction; Radiation dose reduction; Image noise; Spatial resolution; FILTERED BACK-PROJECTION; IMAGE QUALITY; COMPUTED-TOMOGRAPHY; EXPOSURE; KERNEL; NOISE;
D O I
10.1007/s00330-012-2452-z
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
To prospectively evaluate dose reduction and image quality characteristics of chest CT reconstructed with model-based iterative reconstruction (MBIR) compared with adaptive statistical iterative reconstruction (ASIR). One hundred patients underwent reference-dose and low-dose unenhanced chest CT with 64-row multidetector CT. Images were reconstructed with 50 % ASIR-filtered back projection blending (ASIR50) for reference-dose CT, and with ASIR50 and MBIR for low-dose CT. Two radiologists assessed the images in a blinded manner for subjective image noise, artefacts and diagnostic acceptability. Objective image noise was measured in the lung parenchyma. Data were analysed using the sign test and pair-wise Student's t-test. Compared with reference-dose CT, there was a 79.0 % decrease in dose-length product with low-dose CT. Low-dose MBIR images had significantly lower objective image noise (16.93 +/- 3.00) than low-dose ASIR (49.24 +/- 9.11, P < 0.01) and reference-dose ASIR images (24.93 +/- 4.65, P < 0.01). Low-dose MBIR images were all diagnostically acceptable. Unique features of low-dose MBIR images included motion artefacts and pixellated blotchy appearances, which did not adversely affect diagnostic acceptability. Diagnostically acceptable chest CT images acquired with nearly 80 % less radiation can be obtained using MBIR. MBIR shows greater potential than ASIR for providing diagnostically acceptable low-dose CT images without severely compromising image quality. aEuro cent Model-based iterative reconstruction (MBIR) creates high-quality low-dose CT images. aEuro cent MBIR significantly improves image noise and artefacts over adaptive statistical iterative techniques. aEuro cent MBIR shows greater potential than ASIR for diagnostically acceptable low-dose CT. aEuro cent The prolonged processing time of MBIR may currently limit its routine use in clinical practice.
引用
收藏
页码:1613 / 1623
页数:11
相关论文
共 50 条
  • [41] Model-based Iterative Reconstruction and Adaptive Statistical Iterative Reconstruction Techniques in Abdominal CT: Comparison of Image Quality in the Detection of Colorectal Liver Metastases
    Volders, David
    Bols, Alain
    Haspeslagh, Marc
    Coenegrachts, Kenneth
    RADIOLOGY, 2013, 269 (02) : 468 - 473
  • [42] Clinical evaluation of image quality and radiation dose reduction in upper abdominal computed tomography using model-based iterative reconstruction; comparison with filtered back projection and adaptive statistical iterative reconstruction
    Nakamoto, Atsushi
    Kim, Tonsok
    Hori, Masatoshi
    Onishi, Hiromitsu
    Tsuboyama, Takahiro
    Sakane, Makoto
    Tatsumi, Mitsuaki
    Tomiyama, Noriyuki
    EUROPEAN JOURNAL OF RADIOLOGY, 2015, 84 (09) : 1715 - 1723
  • [43] Dose reduction in chest CT: Comparison of the adaptive iterative dose reduction 3D, adaptive iterative dose reduction, and filtered back projection reconstruction techniques
    Yamada, Yoshitake
    Jinzaki, Masahiro
    Hosokawa, Takahiro
    Tanami, Yutaka
    Sugiura, Hiroaki
    Abe, Takayuki
    Kuribayashi, Sachio
    EUROPEAN JOURNAL OF RADIOLOGY, 2012, 81 (12) : 4185 - 4195
  • [44] Filtered Back Projection, Adaptive Statistical Iterative Reconstruction, and a Model-based Iterative Reconstruction in Abdominal CT: An Experimental Clinical Study
    Deak, Zsuzsanna
    Grimm, Jochen M.
    Treitl, Marcus
    Geyer, Lucas L.
    Linsenmaier, Ulrich
    Koerner, Markus
    Reiser, Maximilian F.
    Wirth, Stefan
    RADIOLOGY, 2013, 266 (01) : 197 - 206
  • [45] CT angiography after carotid artery stenting: assessment of the utility of adaptive statistical iterative reconstruction and model-based iterative reconstruction
    Keita Kuya
    Yuki Shinohara
    Makoto Sakamoto
    Naoki Iwata
    Junichi Kishimoto
    Shinya Fujii
    Toshio Kaminou
    Takashi Watanabe
    Toshihide Ogawa
    Neuroradiology, 2014, 56 : 947 - 953
  • [46] CT angiography after carotid artery stenting: assessment of the utility of adaptive statistical iterative reconstruction and model-based iterative reconstruction
    Kuya, Keita
    Shinohara, Yuki
    Sakamoto, Makoto
    Iwata, Naoki
    Kishimoto, Junichi
    Fujii, Shinya
    Kaminou, Toshio
    Watanabe, Takashi
    Ogawa, Toshihide
    NEURORADIOLOGY, 2014, 56 (11) : 947 - 953
  • [47] Image Quality and Radiation Dose in CT Venography Using Model-Based Iterative Reconstruction at 80 kVp versus Adaptive Statistical Iterative Reconstruction-V at 70 kVp
    Park, Chankue
    Choo, Ki Seok
    Kim, Jin Hyeok
    Nam, Kyung Jin
    Lee, Ji Won
    Kim, Jin You
    KOREAN JOURNAL OF RADIOLOGY, 2019, 20 (07) : 1167 - 1175
  • [48] A Prospective Evaluation of Dose Reduction and Image Quality in Chest CT Using Adaptive Statistical Iterative Reconstruction
    Leipsic, Jonathon
    Nguyen, Giang
    Brown, Jaqueline
    Sin, Don
    Mayo, John R.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2010, 195 (05) : 1095 - 1099
  • [49] Estimation of Statistical Weights for Model-Based Iterative CT Reconstruction
    Haase, V
    Stierstorfer, K.
    Hahn, K.
    Schoendube, H.
    Maier, A.
    Noo, F.
    MEDICAL IMAGING 2021: PHYSICS OF MEDICAL IMAGING, 2021, 11595
  • [50] Comparison of the image qualities of filtered back-projection, adaptive statistical iterative reconstruction, and model-based iterative reconstruction for CT venography at 80 kVp
    Kim, Jin Hyeok
    Choo, Ki Seok
    Moon, Tae Yong
    Lee, Jun Woo
    Jeon, Ung Bae
    Kim, Tae Un
    Hwang, Jae Yeon
    Yun, Myeong-Ja
    Jeong, Dong Wook
    Lim, Soo Jin
    EUROPEAN RADIOLOGY, 2016, 26 (07) : 2055 - 2063