Reducing Abdominal CT Radiation Dose With Adaptive Statistical Iterative Reconstruction Technique

被引:401
|
作者
Prakash, Priyanka [1 ,2 ]
Kalra, Mannudeep K. [1 ,2 ]
Kambadakone, Avinash K. [1 ,2 ]
Pien, Homer [1 ,2 ]
Hsieh, Jiang [3 ]
Blake, Michael A. [1 ,2 ]
Sahani, Dushyant V. [1 ,2 ]
机构
[1] Massachusetts Gen Hosp, Dept Radiol, Boston, MA 02114 USA
[2] Harvard Univ, Sch Med, Boston, MA 02114 USA
[3] GE Healthcare, Waukesha, WI USA
关键词
abdominal CT; interative reconstruction; ASIR; radiation dose; COMPUTED-TOMOGRAPHY; IMAGE-QUALITY; ROW CT; REDUCTION; ANGIOGRAPHY; NOISE;
D O I
10.1097/RLI.ob013e3181dzfeec
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To assess radiation dose reduction for abdominal computed tomography (CT) examinations with adaptive statistical iterative reconstruction (ASIR) technique. Materials and Methods: With institutional review board approval, retrospective review of weight adapted abdominal CT exams were performed in 156 consecutive patients with ASIR and in 66 patients with filtered back projection (FBP) on a 64-slice MDCT. Patients were categorized into 3 groups of < 60 kg (n = 42), 61 to 90 kg (n = 100), and >= 91 kg (n = 80) for weight-based adjustment of automatic exposure control technique. Remaining scan parameters were held constant at 1.375:1 pitch, 120 kVp, 55 mm table feed per rotation, 5 mm section thickness. Two radiologists reviewed all CT examinations for image noise and diagnostic acceptability. CT dose index volume, and dose length product were recorded. Image noise and transverse abdominal diameter were measured in all patients. Data were analyzed using analysis of variance. Results: ASIR allowed for an overall average decrease of 25.1% in CT dose index volume compared with the FBP technique (ASIR, 11.9 +/- 3.6 mGy; FBP, 15.9 +/- 4.3 mGy) (P < 0.0001). In each of the 3 weight categories, CT examinations reconstructed with ASIR technique were associated with significantly lower radiation dose compared with FBP technique (P < 0.0001). There was also significantly less objective image noise with ASIR (6.9 +/- 2.2) than with FBP (9.5 +/- 2.0) (P < 0.0001). For the subjective analysis, all ASIR and FBP reconstructed abdominal CTs had optimal or less noise. However, 9% of FBP and 3.8% of ASIR reconstructed CT examinations were diagnostically unacceptable because of the presence of artifacts. Use of ASIR reconstruction kernel results in a blotchy pixilated appearance in 39% of CT sans which however, was mild and did not affect the diagnostic acceptability of images. The critical reproduction of visually sharp anatomic structures was preserved in all but one ASIR 40% reconstructed CT examination. Conclusion: ASIR technique allows radiation dose reduction for abdominal CT examinations whereas improving image noise compared with the FBP technique.
引用
收藏
页码:202 / 210
页数:9
相关论文
共 50 条
  • [31] Adaptive statistical iterative reconstruction: reducing dose while preserving image quality in the pediatric head CT examination
    McKnight, Colin D.
    Watcharotone, Kuanwong
    Ibrahim, Mohannad
    Christodoulou, Emmanuel
    Baer, Aaron H.
    Parmar, Hemant A.
    PEDIATRIC RADIOLOGY, 2014, 44 (08) : 997 - 1003
  • [32] Iterative reconstruction reduces abdominal CT dose
    Martinsen, Anne Catrine Traegde
    Saether, Hilde Kjernlie
    Hol, Per Kristian
    Olsen, Dag Rune
    Skaane, Per
    EUROPEAN JOURNAL OF RADIOLOGY, 2012, 81 (07) : 1483 - 1487
  • [33] Radiation Dose Reduction in Temporal Bone CT with Iterative Reconstruction Technique
    Niu, Y. T.
    Mehta, D.
    Zhang, Z. R.
    Zhang, Y. X.
    Liu, Y. F.
    Kang, T. L.
    Xian, J. F.
    Wang, Z. C.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2012, 33 (06) : 1020 - 1026
  • [34] Model-Based Iterative Reconstruction Technique for Ultralow-Dose Chest CT Comparison of Pulmonary Nodule Detectability With the Adaptive Statistical Iterative Reconstruction Technique
    Katsura, Masaki
    Matsuda, Izuru
    Akahane, Masaaki
    Yasaka, Koichiro
    Hanaoka, Shohei
    Akai, Hiroyuki
    Sato, Jiro
    Kunimatsu, Akira
    Ohtomo, Kuni
    INVESTIGATIVE RADIOLOGY, 2013, 48 (04) : 206 - 212
  • [35] The impact of iterative reconstruction on image quality and radiation dose in thoracic and abdominal CT
    Kalmar, Peter I.
    Quehenberger, Franz
    Steiner, Juergen
    Lutfi, Andre
    Bohlsen, Dennis
    Talakic, Emina
    Hassler, Eva Maria
    Schoellnast, Helmut
    EUROPEAN JOURNAL OF RADIOLOGY, 2014, 83 (08) : 1416 - 1420
  • [36] Feasibility Study of Using Gemstone Spectral Imaging (GSI) and Adaptive Statistical Iterative Reconstruction (ASIR) for Reducing Radiation and Iodine Contrast Dose in Abdominal CT Patients with High BMI Values
    Zhu, Zheng
    Zhao, Xin-ming
    Zhao, Yan-feng
    Wang, Xiao-yi
    Zhou, Chun-wu
    PLOS ONE, 2015, 10 (06):
  • [37] Radiation dose reduction and image quality in pediatric abdominal CT with kVp and mAs modulation and an iterative reconstruction technique
    Kim, Jun-Hwee
    Kim, Myung-Joon
    Kim, Ha Yan
    Lee, Mi-Jung
    CLINICAL IMAGING, 2014, 38 (05) : 710 - 714
  • [38] Impact of adaptive statistical iterative reconstruction on radiation dose in evaluation of trauma patients
    Maxfield, Mark W.
    Schuster, Kevin M.
    McGillicuddy, Edward A.
    Young, Calvin J.
    Ghita, Monica
    Bokhari, S. A. Jamal
    Oliva, Isabel B.
    Brink, James A.
    Davis, Kimberly A.
    JOURNAL OF TRAUMA AND ACUTE CARE SURGERY, 2012, 73 (06): : 1406 - 1411
  • [39] Radiation dose reduction in CT with adaptive statistical iterative reconstruction (ASIR) for patients with bronchial carcinoma and intrapulmonary metastases
    Schaefer, M. -L.
    Luedemann, L.
    Boening, G.
    Kahn, J.
    Fuchs, S.
    Hamm, B.
    Streitparth, F.
    CLINICAL RADIOLOGY, 2016, 71 (05) : 442 - 449
  • [40] Estimated Radiation Dose Reduction Using Adaptive Statistical Iterative Reconstruction in Coronary CT Angiography: The ERASIR Study
    Leipsic, Jonathon
    LaBounty, Troy M.
    Heilbron, Brett
    Min, James K.
    Mancini, G. B. John
    Lin, Fay Y.
    Taylor, Carolyn
    Dunning, Allison
    Earls, James P.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2010, 195 (03) : 655 - 660