Reducing Abdominal CT Radiation Dose With Adaptive Statistical Iterative Reconstruction Technique

被引:401
|
作者
Prakash, Priyanka [1 ,2 ]
Kalra, Mannudeep K. [1 ,2 ]
Kambadakone, Avinash K. [1 ,2 ]
Pien, Homer [1 ,2 ]
Hsieh, Jiang [3 ]
Blake, Michael A. [1 ,2 ]
Sahani, Dushyant V. [1 ,2 ]
机构
[1] Massachusetts Gen Hosp, Dept Radiol, Boston, MA 02114 USA
[2] Harvard Univ, Sch Med, Boston, MA 02114 USA
[3] GE Healthcare, Waukesha, WI USA
关键词
abdominal CT; interative reconstruction; ASIR; radiation dose; COMPUTED-TOMOGRAPHY; IMAGE-QUALITY; ROW CT; REDUCTION; ANGIOGRAPHY; NOISE;
D O I
10.1097/RLI.ob013e3181dzfeec
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To assess radiation dose reduction for abdominal computed tomography (CT) examinations with adaptive statistical iterative reconstruction (ASIR) technique. Materials and Methods: With institutional review board approval, retrospective review of weight adapted abdominal CT exams were performed in 156 consecutive patients with ASIR and in 66 patients with filtered back projection (FBP) on a 64-slice MDCT. Patients were categorized into 3 groups of < 60 kg (n = 42), 61 to 90 kg (n = 100), and >= 91 kg (n = 80) for weight-based adjustment of automatic exposure control technique. Remaining scan parameters were held constant at 1.375:1 pitch, 120 kVp, 55 mm table feed per rotation, 5 mm section thickness. Two radiologists reviewed all CT examinations for image noise and diagnostic acceptability. CT dose index volume, and dose length product were recorded. Image noise and transverse abdominal diameter were measured in all patients. Data were analyzed using analysis of variance. Results: ASIR allowed for an overall average decrease of 25.1% in CT dose index volume compared with the FBP technique (ASIR, 11.9 +/- 3.6 mGy; FBP, 15.9 +/- 4.3 mGy) (P < 0.0001). In each of the 3 weight categories, CT examinations reconstructed with ASIR technique were associated with significantly lower radiation dose compared with FBP technique (P < 0.0001). There was also significantly less objective image noise with ASIR (6.9 +/- 2.2) than with FBP (9.5 +/- 2.0) (P < 0.0001). For the subjective analysis, all ASIR and FBP reconstructed abdominal CTs had optimal or less noise. However, 9% of FBP and 3.8% of ASIR reconstructed CT examinations were diagnostically unacceptable because of the presence of artifacts. Use of ASIR reconstruction kernel results in a blotchy pixilated appearance in 39% of CT sans which however, was mild and did not affect the diagnostic acceptability of images. The critical reproduction of visually sharp anatomic structures was preserved in all but one ASIR 40% reconstructed CT examination. Conclusion: ASIR technique allows radiation dose reduction for abdominal CT examinations whereas improving image noise compared with the FBP technique.
引用
收藏
页码:202 / 210
页数:9
相关论文
共 50 条
  • [1] Reducing abdominal CT radiation dose with the adaptive statistical iterative reconstruction technique in children: a feasibility study
    Vorona, Gregory A.
    Ceschin, Rafael C.
    Clayton, Barbara L.
    Sutcavage, Tom
    Tadros, Sameh S.
    Panigrahy, Ashok
    PEDIATRIC RADIOLOGY, 2011, 41 (09) : 1174 - 1182
  • [2] Reducing abdominal CT radiation dose with the adaptive statistical iterative reconstruction technique in children: a feasibility study
    Gregory A. Vorona
    Rafael C. Ceschin
    Barbara L. Clayton
    Tom Sutcavage
    Sameh S. Tadros
    Ashok Panigrahy
    Pediatric Radiology, 2011, 41 : 1174 - 1182
  • [3] The adaptive statistical iterative reconstruction-V technique for radiation dose reduction in abdominal CT: comparison with the adaptive statistical iterative reconstruction technique
    Kwon, Heejin
    Cho, Jinhan
    Oh, Jongyeong
    Kim, Dongwon
    Cho, Junghyun
    Kim, Sanghyun
    Lee, Sangyun
    Lee, Jihyun
    BRITISH JOURNAL OF RADIOLOGY, 2015, 88 (1054):
  • [4] Reducing dose in SPECT/CT using adaptive statistical iterative reconstruction technique
    Choi, Jinwook
    Choi, Hyeonjun
    Park, Chan Rok
    Cho, Sung Wook
    Kim, Jin Eui
    Lee, Jae Sung
    Lee, Dong Soo
    JOURNAL OF NUCLEAR MEDICINE, 2013, 54
  • [5] Reducing the radiation dose with the adaptive statistical iterative reconstruction technique for chest CT in adults: a parameter study
    Liu Wenyun
    Ding Xiaobo
    Kong Boyu
    Fan Baoyan
    Chen Liang
    中华医学杂志(英文版), 2014, (07) : 1284 - 1288
  • [6] Reducing the radiation dose with the adaptive statistical iterative reconstruction technique for chest CT in adults: a parameter study
    Liu Wenyun
    Ding Xiaobo
    Kong Boyu
    Fan Baoyan
    Chen Liang
    CHINESE MEDICAL JOURNAL, 2014, 127 (07) : 1284 - 1288
  • [7] The adaptive statistical iterative reconstruction-V technique for radiation dose reduction in abdominal CT: comparison with the adaptive statistical iterative reconstruction technique (vol 88, 20150463, 2015)
    Kwon, H.
    Cho, J.
    Oh, J.
    Kim, D.
    Cho, J.
    Kim, S.
    BRITISH JOURNAL OF RADIOLOGY, 2016, 89 (1058):
  • [8] Reducing the Radiation Dose for CT Colonography Using Adaptive Statistical Iterative Reconstruction: A Pilot Study
    Flicek, Kristina T.
    Hara, Amy K.
    Silva, Alvin C.
    Wu, Qing
    Peter, Mary B.
    Johnson, C. Daniel
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2010, 195 (01) : 126 - 131
  • [9] Model-based iterative reconstruction technique for radiation dose reduction in chest CT: comparison with the adaptive statistical iterative reconstruction technique
    Masaki Katsura
    Izuru Matsuda
    Masaaki Akahane
    Jiro Sato
    Hiroyuki Akai
    Koichiro Yasaka
    Akira Kunimatsu
    Kuni Ohtomo
    European Radiology, 2012, 22 : 1613 - 1623
  • [10] Model-based iterative reconstruction technique for radiation dose reduction in chest CT: comparison with the adaptive statistical iterative reconstruction technique
    Katsura, Masaki
    Matsuda, Izuru
    Akahane, Masaaki
    Sato, Jiro
    Akai, Hiroyuki
    Yasaka, Koichiro
    Kunimatsu, Akira
    Ohtomo, Kuni
    EUROPEAN RADIOLOGY, 2012, 22 (08) : 1613 - 1623