Dose Comparison between Proton Pencil Beam and Monte Carlo Dose Calculation Algorithm in Lung Cancer Patients

被引:6
|
作者
Maes, D. [1 ]
Bowen, S. R. [2 ]
Fung, A. [3 ]
Saini, J. [1 ]
Bloch, C. [4 ]
Egan, A. [1 ]
Zeng, J. [5 ]
Rengan, R. [5 ]
Wong, T. P. [1 ]
机构
[1] Seattle Canc Care Alliance Proton Therapy Ctr, Seattle, WA USA
[2] Univ Washington, Radiat Oncol & Radiol, Seattle, WA 98195 USA
[3] SCCA Proton Therapy Ctr, Seattle, WA USA
[4] Univ Washington, Dept Radiat Oncol, Seattle, WA 98195 USA
[5] Univ Washington, Seattle, WA 98195 USA
关键词
D O I
10.1016/j.ijrobp.2017.06.2275
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
3654
引用
收藏
页码:E694 / E694
页数:1
相关论文
共 50 条
  • [1] Comparison of pencil beam algorithm and Monte Carlo dose calculation for proton therapy of paranasal sinus cancer
    Jiang, H
    Adams, J
    Rosenthal, S
    Kollipara, S
    Paganetti, H
    [J]. MEDICAL PHYSICS, 2005, 32 (06) : 2028 - 2028
  • [2] Accuracy of Patient Dose Calculation in Proton Therapy of Lung Cancer: A Comparison of Monte Carlo and Pencil Beam Computations
    Mirkovic, D.
    Tit, U.
    Mohan, R.
    [J]. MEDICAL PHYSICS, 2011, 38 (06)
  • [3] Evaluating Pencil Beam Dose Algorithm in Lung with Monte Carlo
    Depauw, N.
    Seco, J.
    Adams, J.
    Panahandeh, H.
    Paganetti, H.
    Kooy, H.
    [J]. MEDICAL PHYSICS, 2011, 38 (06)
  • [4] SRS Dose Calculation Accuracy Comparison Between Pencil Beam and Monte Carlo Algorithms
    Stathakis, S.
    Defoor, D.
    Saenz, D.
    Kirby, N.
    Mavroidis, P.
    Papanikolaou, N.
    [J]. MEDICAL PHYSICS, 2016, 43 (06) : 3655 - 3655
  • [5] Comparison of Dose Calculation for Brain, Lung, Pelvis and Abdomen Targets with Monte Carlo Simulation and Eclipse Pencil Beam Algorithm
    Prusator, M.
    Muller, L.
    Ahmad, S.
    Chen, Y.
    [J]. MEDICAL PHYSICS, 2018, 45 (06) : E261 - E262
  • [6] Performance of a Hybrid Monte Carlo-Pencil Beam Dose Algorithm for Proton Therapy
    Montero, A. Barragan
    Souris, K.
    Sanchez-Parcerisa, D.
    Lee, J.
    Sterpin, E.
    [J]. MEDICAL PHYSICS, 2017, 44 (06) : 2994 - 2994
  • [7] A comparison of electron beam dose calculation accuracy between treatment planning systems using either a pencil beam or a Monte Carlo algorithm
    Ding, GX
    Cygler, JE
    Yu, CW
    Kalach, NI
    Daskalov, G
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2005, 63 (02): : 622 - 633
  • [8] Clinical validation of Monte Carlo dose calculation for pencil beam scanning proton therapy.
    Widesott, L.
    Lorentini, S.
    Fracchiolla, F.
    Farace, P.
    Schwarz, M.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2018, 127 : S45 - S46
  • [9] Accuracy of patient dose calculation for lung IMRT: A comparison of Monte Carlo, convolution/superposition, and pencil beam computations
    Vanderstraeten, Barbara
    Reynaert, Nick
    Paelinck, Leen
    Madani, Indira
    De Wagter, Carlos
    De Gersem, Werner
    De Neve, Wilfried
    Thierens, Hubert
    [J]. MEDICAL PHYSICS, 2006, 33 (09) : 3149 - 3158
  • [10] A Monte Carlo dose calculation algorithm for proton therapy
    Fippel, M
    Soukup, M
    [J]. MEDICAL PHYSICS, 2004, 31 (08) : 2263 - 2273