Comparison of pencil beam algorithm and Monte Carlo dose calculation for proton therapy of paranasal sinus cancer

被引:1
|
作者
Jiang, H [1 ]
Adams, J [1 ]
Rosenthal, S [1 ]
Kollipara, S [1 ]
Paganetti, H [1 ]
机构
[1] Massachusetts Gen Hosp, Boston, MA 02114 USA
关键词
D O I
10.1118/1.1998068
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To verify the accuracy of the pencil beam algorithm implemented in the FOCUS (CMS) proton treatment planning program with a GEANT4 based Monte Carlo code. Due to the presence of large air cavities and tissue inhomogeneities, paranasal sinus (PNS) cancer brings challenges to radiotherapy treatment planning. Method and Materials: GEANT4 based Monte Carlo methods have been used to simulate multiple PNS cases for the purpose of examining the reliability of the pencil beam algorithm. To guarantee the accuracy of the results by Monte Carlo, the proton treatment nozzle and the patient geometry were modeled in great details, and all related physics processes were included. Different conversion methods for assigning material properties to different Hounsfield units were applied and tested. Electron densities in the Monte Carlo were normalized to the ones used by FOCUS. Results: Monte Carlo and FOCUS present a very good agreement in dose distributions, except for in low‐density air cavities. Monte Carlo reports a significantly lower dose in air than FOCUS, primarily due to a much lower mass stopping power in air than in water. Air cavities, included accidentally in planning contours can cause significant errors in DVHs. With air regions excluded, the DVHs for target structures of Monte Carlo and FOCUS show a good agreement. Differences could be seen in low dose regions and close to material interfaces. However, they are insignificant in most cases. Important, in particular for proton therapy with sharp dose fall‐offs, is the fact that the beam ranges agree very well. Conclusion: This work indicates that the pencil beam algorithm in FOCUS (CMS) is reliable for cases involving large air cavities and bony tissues. However, air cavities should not be included when volumes are drawn for treatment planning. © 2005, American Association of Physicists in Medicine. All rights reserved.
引用
收藏
页码:2028 / 2028
页数:1
相关论文
共 50 条
  • [1] Dose Comparison between Proton Pencil Beam and Monte Carlo Dose Calculation Algorithm in Lung Cancer Patients
    Maes, D.
    Bowen, S. R.
    Fung, A.
    Saini, J.
    Bloch, C.
    Egan, A.
    Zeng, J.
    Rengan, R.
    Wong, T. P.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2017, 99 (02): : E694 - E694
  • [2] Accuracy of Patient Dose Calculation in Proton Therapy of Lung Cancer: A Comparison of Monte Carlo and Pencil Beam Computations
    Mirkovic, D.
    Tit, U.
    Mohan, R.
    [J]. MEDICAL PHYSICS, 2011, 38 (06)
  • [3] Performance of a Hybrid Monte Carlo-Pencil Beam Dose Algorithm for Proton Therapy
    Montero, A. Barragan
    Souris, K.
    Sanchez-Parcerisa, D.
    Lee, J.
    Sterpin, E.
    [J]. MEDICAL PHYSICS, 2017, 44 (06) : 2994 - 2994
  • [4] Clinical validation of Monte Carlo dose calculation for pencil beam scanning proton therapy.
    Widesott, L.
    Lorentini, S.
    Fracchiolla, F.
    Farace, P.
    Schwarz, M.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2018, 127 : S45 - S46
  • [5] A Monte Carlo dose calculation algorithm for proton therapy
    Fippel, M
    Soukup, M
    [J]. MEDICAL PHYSICS, 2004, 31 (08) : 2263 - 2273
  • [6] Monte Carlo Dose Verification of Pencil Beam Scanning Proton Therapy
    Giantsoudi, D.
    Clasie, B.
    Grassberger, C.
    Dowdell, S.
    Depauw, N.
    Madden, T.
    Kooy, H.
    Paganetti, H.
    [J]. MEDICAL PHYSICS, 2013, 40 (06)
  • [7] Monte Carlo vs. pencil-beam dose calculation for uncertainty estimation in proton therapy
    Wahl, N.
    Wieser, H.
    Burigo, L.
    Bangert, M.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2020, 152 : S731 - S731
  • [8] Improvements in pencil beam scanning proton therapy dose calculation accuracy in brain tumor cases with a commercial Monte Carlo algorithm
    Widesott, Lamberto
    Lorentini, Stefano
    Fracchiolla, Francesco
    Farace, Paolo
    Schwarz, Marco
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2018, 63 (14):
  • [9] Performance of a hybrid Monte Carlo-Pencil Beam dose algorithm for proton therapy inverse planning
    Montero, Ana Maria Barragan
    Souris, Kevin
    Sanchez-Parcerisa, Daniel
    Sterpin, Edmond
    Lee, John Aldo
    [J]. MEDICAL PHYSICS, 2018, 45 (02) : 846 - 862
  • [10] Characterization and validation of a Monte Carlo code for independent dose calculation in proton therapy treatments with pencil beam scanning
    Fracchiolla, F.
    Lorentini, S.
    Widesott, L.
    Schwarz, M.
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2015, 60 (21): : 8601 - 8619