Comparison of Dose Calculation for Brain, Lung, Pelvis and Abdomen Targets with Monte Carlo Simulation and Eclipse Pencil Beam Algorithm

被引:0
|
作者
Prusator, M. [1 ]
Muller, L. [1 ]
Ahmad, S. [1 ]
Chen, Y. [1 ]
机构
[1] Univ Oklahoma, Hlth Sci Ctr, Oklahoma City, OK USA
关键词
D O I
暂无
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
SU-I-GPD-T
引用
收藏
页码:E261 / E262
页数:2
相关论文
共 50 条
  • [1] Dose Comparison between Proton Pencil Beam and Monte Carlo Dose Calculation Algorithm in Lung Cancer Patients
    Maes, D.
    Bowen, S. R.
    Fung, A.
    Saini, J.
    Bloch, C.
    Egan, A.
    Zeng, J.
    Rengan, R.
    Wong, T. P.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2017, 99 (02): : E694 - E694
  • [2] Evaluating Pencil Beam Dose Algorithm in Lung with Monte Carlo
    Depauw, N.
    Seco, J.
    Adams, J.
    Panahandeh, H.
    Paganetti, H.
    Kooy, H.
    [J]. MEDICAL PHYSICS, 2011, 38 (06)
  • [3] Comparison of pencil beam algorithm and Monte Carlo dose calculation for proton therapy of paranasal sinus cancer
    Jiang, H
    Adams, J
    Rosenthal, S
    Kollipara, S
    Paganetti, H
    [J]. MEDICAL PHYSICS, 2005, 32 (06) : 2028 - 2028
  • [4] Accuracy of patient dose calculation for lung IMRT: A comparison of Monte Carlo, convolution/superposition, and pencil beam computations
    Vanderstraeten, Barbara
    Reynaert, Nick
    Paelinck, Leen
    Madani, Indira
    De Wagter, Carlos
    De Gersem, Werner
    De Neve, Wilfried
    Thierens, Hubert
    [J]. MEDICAL PHYSICS, 2006, 33 (09) : 3149 - 3158
  • [5] Accuracy of Patient Dose Calculation in Proton Therapy of Lung Cancer: A Comparison of Monte Carlo and Pencil Beam Computations
    Mirkovic, D.
    Tit, U.
    Mohan, R.
    [J]. MEDICAL PHYSICS, 2011, 38 (06)
  • [6] SRS Dose Calculation Accuracy Comparison Between Pencil Beam and Monte Carlo Algorithms
    Stathakis, S.
    Defoor, D.
    Saenz, D.
    Kirby, N.
    Mavroidis, P.
    Papanikolaou, N.
    [J]. MEDICAL PHYSICS, 2016, 43 (06) : 3655 - 3655
  • [7] A comparison of electron beam dose calculation accuracy between treatment planning systems using either a pencil beam or a Monte Carlo algorithm
    Ding, GX
    Cygler, JE
    Yu, CW
    Kalach, NI
    Daskalov, G
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2005, 63 (02): : 622 - 633
  • [8] Improvements in pencil beam scanning proton therapy dose calculation accuracy in brain tumor cases with a commercial Monte Carlo algorithm
    Widesott, Lamberto
    Lorentini, Stefano
    Fracchiolla, Francesco
    Farace, Paolo
    Schwarz, Marco
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2018, 63 (14):
  • [9] Dose to Proximal Bronchial Tree in Lung SBRT Treatments: Comparison of Pencil Beam and Monte Carlo Dose Distributions
    Altunbas, C.
    Miften, M.
    Stuhr, K.
    Gaspar, L.
    Kavanagh, B.
    [J]. MEDICAL PHYSICS, 2010, 37 (06) : 3276 - +
  • [10] Evaluation of the AAA Treatment Planning Algorithm for SBRT Lung Treatment: Comparison with Monte Carlo and Homogeneous Pencil Beam Dose Calculations
    Gete, Ermias
    Teke, Tony
    Kwa, William
    [J]. JOURNAL OF MEDICAL IMAGING AND RADIATION SCIENCES, 2012, 43 (01) : 26 - 33