Evaluation of various low-dose cone-beam computed tomography protocols in the diagnosis of specific condylar defects

被引:0
|
作者
Jager, Fabian [1 ]
Jaeger, Antje [1 ]
Temming, Alexa
Rehm, Phillip [1 ]
Bumann, Axel [1 ]
机构
[1] MESANTIS 3D Dent RADIOLOGICUM, Georgenstr 25, D-10117 Berlin, Germany
关键词
D O I
10.1016/j.ajodo.2020.01.021
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Introduction: This study aimed to determine the identifiability and measurement accuracy of defined bony defects of the temporomandibular joint (TMJ) in cone-beam computed tomographies, depending on different milliampere-second (mAs)-reduced protocols. Methods: Defined artificial defects were prepared on 30 condyles from 15 intact pig heads, with a maximum of surrounding soft tissue preserved. Three-dimensional imaging was performed using ProMax 3D Mid (Planmeca, Helsinki, Finland). The scan protocol with maximum resolution and without mAs-reduction was defined as control. Twenty-six mAs-reduced imaging protocols were analyzed by 1 examiner regarding the protocol-specific measurement accuracy. Defect depth (DD) was divided into 3 categories: I, <2 mm; II, 2-3 mm; and III, >3 mm. The protocol-specific sensitivity and specificity were evaluated in relation to localization and defect size as determined from the results of 3 examiners. Results: There was a significant difference from the control protocol in DD measurement in 8 mAs-reduced protocols, P<0.001-0.027. In most protocols, there was no significant difference in measurement accuracy concerning defect size and localization. The mean sensitivity reached values between 93.3% and 98.6% and differed significantly among protocols (P = 0.002). The mean specificity amounted to 97.0%-98.1% and did not differ among protocols (P = 0.462). The specificity of DD III (99.1%) was higher than DD I (97.7%) and DD II (97.1%). There was a significant difference in specificity and sensitivity concerning defect localization (P<0.001). Conclusions: This study showed that mAs-reduced cone-beam computed tomographies protocols are suitable for the analysis of defined osseous TMJ defects. When 3-dimensional TMJ imaging is indicated because of potential erosive defects, validated mAs-reduced scan protocols should be applied instead of high-definition protocols.
引用
收藏
页码:491 / U39
页数:13
相关论文
共 50 条
  • [41] Evaluation of the pharyngeal recess with cone-beam computed tomography
    Erdem, Sule
    Zengin, Ayse Zeynep
    Erdem, Suheda
    SURGICAL AND RADIOLOGIC ANATOMY, 2020, 42 (11) : 1307 - 1313
  • [42] Evaluation of the pharyngeal recess with cone-beam computed tomography
    Şule Erdem
    Ayşe Zeynep Zengin
    Şuheda Erdem
    Surgical and Radiologic Anatomy, 2020, 42 : 1307 - 1313
  • [43] Compensators for dose and scatter management in cone-beam computed tomography
    Graham, S. A.
    Moseley, D. J.
    Siewerdsen, J. H.
    Jaffray, D. A.
    MEDICAL PHYSICS, 2007, 34 (07) : 2691 - 2703
  • [44] Evaluation of horizontal condylar angle in malocclusions with mandibular lateral displacement using cone-beam computed tomography
    Velasquez, Roberto L.
    Coro, Jorge C.
    Bustillo, Jose M.
    Sato, Sadao
    ANGLE ORTHODONTIST, 2021, 91 (06) : 815 - 821
  • [45] Could Low-dose Cone-beam CT be Used for Endodontic Intraoperative Diagnosis?
    de Lima, Joao Pedro
    Mazzi-Chaves, Jardel Francisco
    de Sousa-Neto, Manoel Damiao
    Candemil, Amanda Pelegrin
    JOURNAL OF ENDODONTICS, 2023, 49 (09) : 1161 - 1168
  • [46] Dose indices of kilovoltage cone beam computed tomography for various image guided radiotherapy protocols
    Gazdag-Hegyesi, Szilvia
    Galdi, Adam
    Major, Tibor
    Pesznyak, Csilla
    RADIATION PROTECTION DOSIMETRY, 2023, 199 (8-9) : 983 - 988
  • [47] Automated dose evaluation on daily cone-beam computed tomography for breast cancer patients
    Koerkamp, Maureen Groot
    Stijnman, Peter
    Houweling, Antonetta
    Zachiu, Cornel
    Kotte, Alexis
    Raaymakers, Bas
    RADIOTHERAPY AND ONCOLOGY, 2024, 200
  • [48] Cone-beam computed tomography for routine orthodontic treatment planning: A radiation dose evaluation
    Garcia Silva, Maria Alves
    Wolf, Ulrich
    Heinicke, Frank
    Bumann, Axel
    Visser, Heiko
    Hirsch, Edgar
    AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2008, 133 (05) : 640.e1 - 640.e5
  • [49] Evaluation of a cone-beam computed tomography system calibrated for accurate radiotherapy dose calculation
    Bogowicz, Marta
    Lustermans, Didier
    Taasti, Vicki Trier
    Hazelaar, Colien
    Verhaegen, Frank
    Fonseca, Gabriel Paiva
    van Elmpt, Wouter
    PHYSICS & IMAGING IN RADIATION ONCOLOGY, 2024, 29
  • [50] Cone-Beam Computed Tomography - A Useful Tool in Orthodontic Diagnosis
    Anistoroaei, Daniela
    Zegan, Georgeta
    Golovcencu, Loredana
    Cernei, Eduard Radu
    Sodor-Botezatu, Alina
    Saveanu, Iulia Catalina
    2019 E-HEALTH AND BIOENGINEERING CONFERENCE (EHB), 2019,