Evaluation of various low-dose cone-beam computed tomography protocols in the diagnosis of specific condylar defects

被引:0
|
作者
Jager, Fabian [1 ]
Jaeger, Antje [1 ]
Temming, Alexa
Rehm, Phillip [1 ]
Bumann, Axel [1 ]
机构
[1] MESANTIS 3D Dent RADIOLOGICUM, Georgenstr 25, D-10117 Berlin, Germany
关键词
D O I
10.1016/j.ajodo.2020.01.021
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Introduction: This study aimed to determine the identifiability and measurement accuracy of defined bony defects of the temporomandibular joint (TMJ) in cone-beam computed tomographies, depending on different milliampere-second (mAs)-reduced protocols. Methods: Defined artificial defects were prepared on 30 condyles from 15 intact pig heads, with a maximum of surrounding soft tissue preserved. Three-dimensional imaging was performed using ProMax 3D Mid (Planmeca, Helsinki, Finland). The scan protocol with maximum resolution and without mAs-reduction was defined as control. Twenty-six mAs-reduced imaging protocols were analyzed by 1 examiner regarding the protocol-specific measurement accuracy. Defect depth (DD) was divided into 3 categories: I, <2 mm; II, 2-3 mm; and III, >3 mm. The protocol-specific sensitivity and specificity were evaluated in relation to localization and defect size as determined from the results of 3 examiners. Results: There was a significant difference from the control protocol in DD measurement in 8 mAs-reduced protocols, P<0.001-0.027. In most protocols, there was no significant difference in measurement accuracy concerning defect size and localization. The mean sensitivity reached values between 93.3% and 98.6% and differed significantly among protocols (P = 0.002). The mean specificity amounted to 97.0%-98.1% and did not differ among protocols (P = 0.462). The specificity of DD III (99.1%) was higher than DD I (97.7%) and DD II (97.1%). There was a significant difference in specificity and sensitivity concerning defect localization (P<0.001). Conclusions: This study showed that mAs-reduced cone-beam computed tomographies protocols are suitable for the analysis of defined osseous TMJ defects. When 3-dimensional TMJ imaging is indicated because of potential erosive defects, validated mAs-reduced scan protocols should be applied instead of high-definition protocols.
引用
收藏
页码:491 / U39
页数:13
相关论文
共 50 条
  • [11] Evaluation and Correlation of Condylar Cortication by Cone-Beam Computed Tomography: A Retrospective Study
    Muthlakshmi, K. Sethna
    Krithika, C.
    Asokan, Kannan
    CONTEMPORARY CLINICAL DENTISTRY, 2022, 13 (01) : 30 - 34
  • [12] EVALUATION OF DOSE HOMOGENEITY IN CONE-BEAM BREAST COMPUTED TOMOGRAPHY
    Mettivier, Giovanni
    Costa, Matilde
    Lanconelli, Nico
    Ianiro, Anna
    Pugliese, Mariagabriella
    Quarto, Maria
    Russo, Paolo
    RADIATION PROTECTION DOSIMETRY, 2017, 175 (04) : 473 - 481
  • [13] Evaluation of a low-dose protocol for cone beam computed tomography of the temporomandibular joint
    Iskanderani, Durer
    Nilsson, Mats
    Alstergren, Per
    Shi, Xie-Qi
    Hellen-Halme, Kristina
    DENTOMAXILLOFACIAL RADIOLOGY, 2021, 50 (01)
  • [14] Evaluation of a low-dose protocol for cone beam computed tomography of the temporomandibular joint
    Iskanderani, Durer
    Nilsson, Mats
    Alstergren, Per
    Shi, Xie-Qi
    Hellen-Halme, Kristina
    DENTOMAXILLOFACIAL RADIOLOGY, 2020, 49 (06)
  • [15] Cone-Beam Computed Tomography Study of Mandibular Condylar Morphology
    Yalcin, Eda Didem
    Ararat, Emine
    JOURNAL OF CRANIOFACIAL SURGERY, 2019, 30 (08) : 2621 - 2624
  • [16] Cone-beam computed tomography for the diagnosis of mandibular condylar fractures: 11 case reports
    Kunihito Matsumoto
    Kunihiko Sawada
    Shigeo Kameoka
    Yoshiyuki Yonehara
    Kazuya Honda
    Oral Radiology, 2013, 29 : 80 - 86
  • [17] Cone-beam computed tomography for the diagnosis of mandibular condylar fractures: 11 case reports
    Matsumoto, Kunihito
    Sawada, Kunihiko
    Kameoka, Shigeo
    Yonehara, Yoshiyuki
    Honda, Kazuya
    ORAL RADIOLOGY, 2013, 29 (01) : 80 - 86
  • [18] Image quality assessment of low-dose protocols in cone beam computed tomography of the anterior maxilla
    Ihlis, Randi Lynds
    Kadesjo, Nils
    Tsilingaridis, Georgios
    Benchimol, Daniel
    Shi, Xie Qi
    ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY, 2022, 133 (04): : 483 - 491
  • [19] Cone beam computed tomography for dental and maxillofacial imaging: technique improvement and low-dose protocols
    Feragalli, Beatrice
    Rampado, Osvaldo
    Abate, Cecilia
    Macri, Monica
    Festa, Felice
    Stromei, Francesco
    Caputi, Sergio
    Guglielmi, Giuseppe
    RADIOLOGIA MEDICA, 2017, 122 (08): : 581 - 588
  • [20] Cone beam computed tomography for dental and maxillofacial imaging: technique improvement and low-dose protocols
    Beatrice Feragalli
    Osvaldo Rampado
    Cecilia Abate
    Monica Macrì
    Felice Festa
    Francesco Stromei
    Sergio Caputi
    Giuseppe Guglielmi
    La radiologia medica, 2017, 122 : 581 - 588