Evaluation of various low-dose cone-beam computed tomography protocols in the diagnosis of specific condylar defects

被引:0
|
作者
Jager, Fabian [1 ]
Jaeger, Antje [1 ]
Temming, Alexa
Rehm, Phillip [1 ]
Bumann, Axel [1 ]
机构
[1] MESANTIS 3D Dent RADIOLOGICUM, Georgenstr 25, D-10117 Berlin, Germany
关键词
D O I
10.1016/j.ajodo.2020.01.021
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Introduction: This study aimed to determine the identifiability and measurement accuracy of defined bony defects of the temporomandibular joint (TMJ) in cone-beam computed tomographies, depending on different milliampere-second (mAs)-reduced protocols. Methods: Defined artificial defects were prepared on 30 condyles from 15 intact pig heads, with a maximum of surrounding soft tissue preserved. Three-dimensional imaging was performed using ProMax 3D Mid (Planmeca, Helsinki, Finland). The scan protocol with maximum resolution and without mAs-reduction was defined as control. Twenty-six mAs-reduced imaging protocols were analyzed by 1 examiner regarding the protocol-specific measurement accuracy. Defect depth (DD) was divided into 3 categories: I, <2 mm; II, 2-3 mm; and III, >3 mm. The protocol-specific sensitivity and specificity were evaluated in relation to localization and defect size as determined from the results of 3 examiners. Results: There was a significant difference from the control protocol in DD measurement in 8 mAs-reduced protocols, P<0.001-0.027. In most protocols, there was no significant difference in measurement accuracy concerning defect size and localization. The mean sensitivity reached values between 93.3% and 98.6% and differed significantly among protocols (P = 0.002). The mean specificity amounted to 97.0%-98.1% and did not differ among protocols (P = 0.462). The specificity of DD III (99.1%) was higher than DD I (97.7%) and DD II (97.1%). There was a significant difference in specificity and sensitivity concerning defect localization (P<0.001). Conclusions: This study showed that mAs-reduced cone-beam computed tomographies protocols are suitable for the analysis of defined osseous TMJ defects. When 3-dimensional TMJ imaging is indicated because of potential erosive defects, validated mAs-reduced scan protocols should be applied instead of high-definition protocols.
引用
收藏
页码:491 / U39
页数:13
相关论文
共 50 条
  • [21] Reproducibility of three-dimensional cephalometric landmarks in cone-beam and low-dose computed tomography
    R. Olszewski
    L. Frison
    M. Wisniewski
    J. M. Denis
    S. Vynckier
    G. Cosnard
    F. Zech
    H. Reychler
    Clinical Oral Investigations, 2013, 17 : 285 - 292
  • [22] Evaluation of cone-beam computed tomography in the diagnosis of simulated small osseous defects in the mandibular condyle
    Patel, Alpesh
    Tee, Boon Ching
    Fields, Henry
    Jones, Elizabeth
    Chaudhry, Jahanzeb
    Sun, Zongyang
    AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2014, 145 (02) : 143 - 156
  • [23] A Comparative Study of Noise-Reduction Algorithms for Low-Dose Cone-Beam Computed Tomography
    Mukherjee, S.
    Yao, W.
    MEDICAL PHYSICS, 2015, 42 (06) : 3201 - 3201
  • [24] Reproducibility of three-dimensional cephalometric landmarks in cone-beam and low-dose computed tomography
    Olszewski, R.
    Frison, L.
    Wisniewski, M.
    Denis, J. M.
    Vynckier, S.
    Cosnard, G.
    Zech, F.
    Reychler, H.
    CLINICAL ORAL INVESTIGATIONS, 2013, 17 (01) : 285 - 292
  • [25] Low-dose Multidetector Computed Tomographic and Cone-beam Computed Tomographic Protocols for Volumetric Measurement of Simulated Periapical Lesions
    Trindade, Jessica Lopes
    Liedke, Gabriela Salatino
    Tiburcio-Machado, Camilla dos Santos
    Silva Barcelos, Raquel Cristine
    Dotto, Gustavo Nogara
    Souza Bier, Carlos Alexandre
    JOURNAL OF ENDODONTICS, 2021, 47 (07) : 1144 - 1148
  • [26] Cone-Beam Computed Tomography (CBCT)-Based Diagnosis of Dental Bone Defects
    Alshomrani, Faisal
    DIAGNOSTICS, 2024, 14 (13)
  • [27] Kilovoltage cone-beam computed tomography imaging dose estimation and optimization: Need of daily cone-beam computed tomography
    Trivedi, Gaurav
    Dixit, Chandra K.
    Oinam, Arun S.
    Kapoor, Rakesh
    Bahl, Amit
    JOURNAL OF CANCER RESEARCH AND THERAPEUTICS, 2019, 15 (03) : 470 - 474
  • [28] Assessment of optimal condylar position with limited cone-beam computed tomography
    Ikeda, Kazumi
    Kawamura, Akira
    AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2009, 135 (04) : 495 - 501
  • [29] Detectability of Osseous Lesions with a Pre-Programmed Low-Dose Protocol for Cone-Beam Computed Tomography
    Dobelin, Quirin
    Stadlinger, Bernd
    Wiedemeier, Daniel B.
    Bichsel, Dominique
    Rucker, Martin
    Valdec, Silvio
    APPLIED SCIENCES-BASEL, 2020, 10 (14):
  • [30] Fast, Iterative, Low-Dose, Cone-Beam Computed Tomography Reconstruction Using a Gradient Projection Algorithm
    Park, J.
    Song, B.
    Kim, J.
    Park, S.
    Kim, H.
    Suh, T.
    Liu, Z.
    Song, W.
    MEDICAL PHYSICS, 2011, 38 (06)