Evaluation of various low-dose cone-beam computed tomography protocols in the diagnosis of specific condylar defects

被引:0
|
作者
Jager, Fabian [1 ]
Jaeger, Antje [1 ]
Temming, Alexa
Rehm, Phillip [1 ]
Bumann, Axel [1 ]
机构
[1] MESANTIS 3D Dent RADIOLOGICUM, Georgenstr 25, D-10117 Berlin, Germany
关键词
D O I
10.1016/j.ajodo.2020.01.021
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Introduction: This study aimed to determine the identifiability and measurement accuracy of defined bony defects of the temporomandibular joint (TMJ) in cone-beam computed tomographies, depending on different milliampere-second (mAs)-reduced protocols. Methods: Defined artificial defects were prepared on 30 condyles from 15 intact pig heads, with a maximum of surrounding soft tissue preserved. Three-dimensional imaging was performed using ProMax 3D Mid (Planmeca, Helsinki, Finland). The scan protocol with maximum resolution and without mAs-reduction was defined as control. Twenty-six mAs-reduced imaging protocols were analyzed by 1 examiner regarding the protocol-specific measurement accuracy. Defect depth (DD) was divided into 3 categories: I, <2 mm; II, 2-3 mm; and III, >3 mm. The protocol-specific sensitivity and specificity were evaluated in relation to localization and defect size as determined from the results of 3 examiners. Results: There was a significant difference from the control protocol in DD measurement in 8 mAs-reduced protocols, P<0.001-0.027. In most protocols, there was no significant difference in measurement accuracy concerning defect size and localization. The mean sensitivity reached values between 93.3% and 98.6% and differed significantly among protocols (P = 0.002). The mean specificity amounted to 97.0%-98.1% and did not differ among protocols (P = 0.462). The specificity of DD III (99.1%) was higher than DD I (97.7%) and DD II (97.1%). There was a significant difference in specificity and sensitivity concerning defect localization (P<0.001). Conclusions: This study showed that mAs-reduced cone-beam computed tomographies protocols are suitable for the analysis of defined osseous TMJ defects. When 3-dimensional TMJ imaging is indicated because of potential erosive defects, validated mAs-reduced scan protocols should be applied instead of high-definition protocols.
引用
收藏
页码:491 / U39
页数:13
相关论文
共 50 条
  • [1] Do cone-beam computed tomography low-dose protocols affect the evaluation of the temporomandibular joint?
    Reis, Larissa de Oliveira
    Gaeta-Araujo, Hugo
    Lopes Rosado, Lucas P.
    Mouzinho-Machado, Samia
    Oliveira-Santos, Christiano
    Freitas, Deborah Queiroz
    Correr-Sobrinho, Lourenco
    JOURNAL OF ORAL REHABILITATION, 2023, 50 (01) : 1 - 11
  • [2] Low-dose cone-beam computed tomography in simulated condylar erosion detection: a diagnostic accuracy study
    Noha Saleh Abu-Taleb
    Dina Mohamed ElBeshlawy
    Oral Radiology, 2021, 37 : 427 - 435
  • [3] Low-dose cone-beam computed tomography in simulated condylar erosion detection: a diagnostic accuracy study
    Abu-Taleb, Noha Saleh
    ElBeshlawy, Dina Mohamed
    ORAL RADIOLOGY, 2021, 37 (03) : 427 - 435
  • [4] Advances in Imaging (Intraop Cone-Beam Computed Tomography, Synthetic Computed Tomography, Bone Scan, Low-Dose Protocols)
    Jankowski, Pawel P.
    Chan, Justin P.
    NEUROSURGERY CLINICS OF NORTH AMERICA, 2024, 35 (02) : 161 - 172
  • [5] Optimization of orofacial cleft imaging protocols using device-specific low-dose cone-beam computed tomography
    Shujaat, Sohaib
    Vasconcelos, Karla de Faria
    Kesztyus, Artur
    Fontenele, Rocharles Cavalcante
    Oliveira-Santos, Nicolly
    Nagy, Krisztian
    Shaheen, Eman
    Jacobs, Reinhilde
    JOURNAL OF ORAL REHABILITATION, 2024, 51 (09) : 1712 - 1720
  • [6] Imaging furcation defects with low-dose cone beam computed tomography
    Maurice Ruetters
    Holger Gehrig
    Ti-Sun Kim
    Valentin Bartha
    Thomas Bruckner
    Franz Sebastian Schwindling
    Anna Felten
    Christopher Lux
    Sinan Sen
    Scientific Reports, 12
  • [7] Imaging furcation defects with low-dose cone beam computed tomography
    Ruetters, Maurice
    Gehrig, Holger
    Kim, Ti-Sun
    Bartha, Valentin
    Bruckner, Thomas
    Schwindling, Franz Sebastian
    Felten, Anna
    Lux, Christopher
    Sen, Sinan
    SCIENTIFIC REPORTS, 2022, 12 (01)
  • [8] Evaluation of condyle defects using different reconstruction protocols of cone-beam computed tomography
    Bastos, Luana Costa
    Flores Campos, Paulo Sergio
    de Moraes Ramos-Perez, Flavia Maria
    Pontual, Andrea dos Anjos
    Almeida, Solange Maria
    BRAZILIAN ORAL RESEARCH, 2013, 27 (06) : 503 - 509
  • [9] Comparison of cone-beam computed tomography with multislice computed tomography in detection of small osseous condylar defects
    Jones, Elizabeth M.
    Papio, Melissa
    Tee, Boon Ching
    Beck, Frank M.
    Fields, Henry W.
    Sun, Zongyang
    AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2016, 150 (01) : 130 - 139
  • [10] Recent Development of Low-dose X-ray Cone-beam Computed Tomography
    Wang, Jing
    Liang, Zhengrong
    Lu, Hongbing
    Xing, Lei
    CURRENT MEDICAL IMAGING, 2010, 6 (02) : 72 - 81