Analytical model for dental implant insertion torque

被引:7
|
作者
Yang, Baixuan [1 ]
Irastorza-Landa, Ainara [2 ]
Heuberger, Peter [2 ]
Ploeg, Heidi-Lynn [1 ]
机构
[1] Queens Univ Kingston, Dept Mech & Mat Engn, McLaughlin Hall,130 Stuart St, Kingston, ON K7L 3N6, Canada
[2] Nobel Biocare Serv AG, Balz Zimmermann Str 7, CH-8302 Kloten, Switzerland
基金
加拿大自然科学与工程研究理事会;
关键词
Dental implant; Torque; Model; PRIMARY STABILITY; BONE-DENSITY; OSSEOINTEGRATION; MECHANICS;
D O I
10.1016/j.jmbbm.2022.105223
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Maximum insertion torque (IT) for threaded dental implants is a primary clinical measurement to assess implant anchorage, and strongly influences the clinical outcome. Insertion torque is influenced by surgical technique, implant designs, and patient factors such as bone density and quality. In this study, an analytical model was proposed for IT to estimate contributions from the thread and taper separately. The purpose of this study was to test if the analytical model could 1. differentiate the parallel-walled and tapered implant; and, 2. represent four factors: bone surrogate density, drill protocol, implant surface finish and cutting flute. The IT was modeled as the sum of the torques from the thread's inclined plane and interface shear stress from the tapered body integrated over the surface area, respectively, with two main parameters: effective force, F ', F ' and effective pressure, p '. The effective force, relates to the clamping force from the thread, while the effective pressure, p ', associates with the contact pressure at the bone-implant interface. The model performed well (R2 = 0.88-1.0) and differentiated between the parallel-walled (p ' = 0) and tapered implants (p ' = 0.12). The model's parameters could individually represent the effects of the four factors. High bone surrogate density, two-step drill protocol, and rough surface increased both F ' and p '. The cutting flute had opposing effects on F ' and p ' (beta 4 = 0.35 and -0.24, respectively); and therefore, had the lowest net effect on IT. The proposed analytical model therefore improves the understanding of the principal contributors to dental implant IT by considering thread and taper mechanics independently.
引用
收藏
页数:8
相关论文
共 50 条
  • [1] Oblique Cutting Based Mechanical Model for Insertion Torque of Dental Implant
    Li, Luli
    Zhang, Song
    Li, Quhao
    Bian, Cuirong
    Zhang, Airong
    CHINESE JOURNAL OF MECHANICAL ENGINEERING, 2022, 35 (01)
  • [2] Oblique Cutting Based Mechanical Model for Insertion Torque of Dental Implant
    Luli Li
    Song Zhang
    Quhao Li
    Cuirong Bian
    Airong Zhang
    Chinese Journal of Mechanical Engineering, 2022, 35 (03) : 106 - 119
  • [3] Oblique Cutting Based Mechanical Model for Insertion Torque of Dental Implant
    Luli Li
    Song Zhang
    Quhao Li
    Cuirong Bian
    Airong Zhang
    Chinese Journal of Mechanical Engineering, 2022, 35
  • [4] Experimental study to establishing the insertion torque on dental implant
    Isabel Lopez-Gualdron, Clara
    Fernando Galeano-Arrieta, Carlos
    Cesar Pinillos, Julio
    Carlos Moreno, Juan
    REVISTA ITECKNE, 2014, 11 (01): : 17 - 26
  • [5] Insertion Torque Function Analysis of Novel Dental Implant Geometry
    Pammer, D.
    Bognar, E.
    FIRST EUROPEAN BIOMEDICAL ENGINEERING CONFERENCE FOR YOUNG INVESTIGATORS, 2015, 50 : 83 - 86
  • [6] Insertion torque and resonance frequency analysis of dental implant systems in an animal model with loaded implants
    Al-Nawas, Bilal
    Wagner, Wilfried
    Groetz, Knut A.
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2006, 21 (05) : 726 - 732
  • [7] Insertion torque and resonance frequency analysis of dental implant systems in an animal model with loaded implants
    Al-Nawas, Bilal
    Wagner, Wilfried
    Groetz, Knut A.
    IMPLANTOLOGIE, 2008, 16 (01): : 11 - 20
  • [8] Effect of insertion factors on dental implant insertion torque/energy-experimental results
    Yang, Baixuan
    Irastorza-Landa, Ainara
    Heuberger, Peter
    Ploeg, Heidi-Lynn
    JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS, 2020, 112
  • [9] Measurement of bone deformation and insertion torque during dental implant installation
    Nascimento, Larissa Ramos Xavier Coutinho
    Torelly, Guilherme Monteiro
    Elias, Carlos Nelson
    ORAL AND MAXILLOFACIAL SURGERY-HEIDELBERG, 2024, 29 (01):
  • [10] Microstructure-based numerical computational method for the insertion torque of dental implant
    Li, Luli
    Zhang, Song
    Li, Quhao
    Bian, Cuirong
    Zhang, Airong
    JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS, 2019, 98 : 137 - 147