Dose performance and image quality: Dual source CT versus single source CT in cardiac CT angiography

被引:21
|
作者
Wang, Min [1 ]
Qi, Heng-Tao
Wang, Xi-Ming
Wang, Tao
Chen, Jiu-Hong [2 ]
Liu, Cheng [1 ]
机构
[1] Shandong Univ, Coll Med, Shandong Med Imaging Res Inst, Jinan 250012, Shandong, Peoples R China
[2] Siemens Ltd China, Beijing 100102, Peoples R China
关键词
Dual source CT; Single source CT; Cardiac CT angiography; Radiation dose; Image quality; MULTIDETECTOR ROW CT; TOMOGRAPHY CORONARY-ANGIOGRAPHY; HEART-RATE-VARIABILITY; COMPUTED-TOMOGRAPHY; 64-SECTION CT; RECONSTRUCTION; EXPERIENCE; ACCURACY; ARTERIES;
D O I
10.1016/j.ejrad.2008.08.010
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objective: To evaluate dose performance and image quality of 64-slice dual source CT(DSCT) in comparison to 64-slice single source CT (SSCT) in cardiac CT angiography (CTA). Methods: 100 patients examined by DSCT and 60 patients scanned by SSCT were included in this study. Objective indices such as image noise, contrast-to-noise ratio and signal-to-noise ratio were analyzed. Subjective image quality was assessed by two cardiovascular radiologists in consensus using a four-point scale (1 = excellent to 4 = not acceptable). Estimation of effective dose was performed on the basis of dose length product (DLP). Results: At low heart rates (<70 bpm), image quality of SSCT was equivalent to that of DSCT (P>0.05), but, at high heart rates (>70 bpm), DSCT provided robust image quality (P<0.05). The average effective dose of SSCT was 9.3 +/- 0.9 mSv at low heart rates (<70 bpm) while, the average estimated effective doses of DSCT were 9.1 +/- 1.3 mSv, 8.3 +/- 1.1 mSv, 7.9 +/- 1.1 mSv, 6.9 +/- 0.7 mSv, and 5.9 +/- 1.3 mSv, corresponding to heart rates of 50-59 bpm, 60-69 bpm, 70-79 bpm, 80-89 bpm, and 90-100 bpm. Conclusion: For cardiac CTA, both DSCT and SSCT can get good image quality at low heart rates (<70 bpm) with a similar radiation dose, but, at high heart rates (>70 bpm), DSCT is able to provide robust diagnostic image quality at doses far below that of SSCT. (C) 2008 Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:396 / 400
页数:5
相关论文
共 50 条
  • [31] Image reconstruction and image quality evaluation for a dual source CT scanner
    Flohr, T. G.
    Bruder, H.
    Stierstorfer, K.
    Petersilka, M.
    Schmidt, B.
    McCollough, C. H.
    MEDICAL PHYSICS, 2008, 35 (12) : 5882 - 5897
  • [32] Single- and dual-energy CT pulmonary angiography using second- and third-generation dual-source CT systems: comparison of radiation dose and image quality
    Lukas Lenga
    Franziska Trapp
    Moritz H. Albrecht
    Julian L. Wichmann
    Addison A. Johnson
    Ibrahim Yel
    Tommaso D’Angelo
    Christian Booz
    Thomas J. Vogl
    Simon S. Martin
    European Radiology, 2019, 29 : 4603 - 4612
  • [33] Dual-source CT coronary angiography: factors determining image quality and diagnostic accuracy
    Yerramasu, A.
    Venuraju, S.
    Atwal, S.
    Goodman, D.
    Lipkin, D.
    Lahiri, A.
    EUROPEAN HEART JOURNAL SUPPLEMENTS, 2011, 13 (0A) : A71 - A71
  • [34] Potential dose reduction and image quality improvement in chest CT with a photon-counting CT compared to a new dual-source CT
    Greffier, Joel
    Dabli, Djamel
    Faby, Sebastian
    Pastor, Maxime
    de Oliveira, Fabien
    Croisille, Cedric
    Erath, Julien
    Beregi, Jean-Paul
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2024, 127
  • [35] High-Pitch CT Pulmonary Angiography in Third Generation Dual-Source CT: Image Quality in an Unselected Patient Population
    Sabel, Bastian O.
    Buric, Kristijan
    Karara, Nora
    Thierfelder, Kolja M.
    Dinkel, Julien
    Sommer, Wieland H.
    Meinel, Felix G.
    PLOS ONE, 2016, 11 (02):
  • [36] The ascending aortic image quality and the whole aortic radiation dose of high-pitch dual-source CT angiography
    Liu, Ying
    Xu, Jian
    Li, Jian
    Ren, Jing
    Liu, Hongtao
    Xu, Junqing
    Wei, Mengqi
    Hao, Yuewen
    Zheng, Minwen
    JOURNAL OF CARDIOTHORACIC SURGERY, 2013, 8
  • [37] The ascending aortic image quality and the whole aortic radiation dose of high-pitch dual-source CT angiography
    Ying Liu
    Jian Xu
    Jian Li
    Jing Ren
    Hongtao Liu
    Junqing Xu
    Mengqi Wei
    Yuewen Hao
    Minwen Zheng
    Journal of Cardiothoracic Surgery, 8
  • [38] Dose levels at coronary CT angiography—a comparison of Dual Energy-, Dual Source- and 16-slice CT
    J. Matthias Kerl
    Ralf W. Bauer
    Tobias B. Maurer
    Rene Aschenbach
    Huedayi Korkusuz
    Thomas Lehnert
    Simon Deseive
    Hanns Ackermann
    Thomas J. Vogl
    European Radiology, 2011, 21 : 530 - 537
  • [39] Radiation Dose Reduction of Chest CT with Iterative Reconstruction in Image Space - Part I: Studies on Image Quality Using Dual Source CT
    Hwang, Hye Jeon
    Seo, Joon Beom
    Lee, Jin Seong
    Song, Jae-Woo
    Kim, Song Soo
    Lee, Hyun Joo
    Lim, Chae Hun
    KOREAN JOURNAL OF RADIOLOGY, 2012, 13 (06) : 711 - 719
  • [40] Feasibility of a single-heart beat scan protocol in dual-source cardiac CT angiography
    Bischoff, B.
    Hein, F.
    Meyer, T.
    Hadamitzky, M.
    Martinoff, S.
    Hausleiter, J.
    EUROPEAN HEART JOURNAL, 2009, 30 : 488 - 489