Dose performance and image quality: Dual source CT versus single source CT in cardiac CT angiography

被引:21
|
作者
Wang, Min [1 ]
Qi, Heng-Tao
Wang, Xi-Ming
Wang, Tao
Chen, Jiu-Hong [2 ]
Liu, Cheng [1 ]
机构
[1] Shandong Univ, Coll Med, Shandong Med Imaging Res Inst, Jinan 250012, Shandong, Peoples R China
[2] Siemens Ltd China, Beijing 100102, Peoples R China
关键词
Dual source CT; Single source CT; Cardiac CT angiography; Radiation dose; Image quality; MULTIDETECTOR ROW CT; TOMOGRAPHY CORONARY-ANGIOGRAPHY; HEART-RATE-VARIABILITY; COMPUTED-TOMOGRAPHY; 64-SECTION CT; RECONSTRUCTION; EXPERIENCE; ACCURACY; ARTERIES;
D O I
10.1016/j.ejrad.2008.08.010
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objective: To evaluate dose performance and image quality of 64-slice dual source CT(DSCT) in comparison to 64-slice single source CT (SSCT) in cardiac CT angiography (CTA). Methods: 100 patients examined by DSCT and 60 patients scanned by SSCT were included in this study. Objective indices such as image noise, contrast-to-noise ratio and signal-to-noise ratio were analyzed. Subjective image quality was assessed by two cardiovascular radiologists in consensus using a four-point scale (1 = excellent to 4 = not acceptable). Estimation of effective dose was performed on the basis of dose length product (DLP). Results: At low heart rates (<70 bpm), image quality of SSCT was equivalent to that of DSCT (P>0.05), but, at high heart rates (>70 bpm), DSCT provided robust image quality (P<0.05). The average effective dose of SSCT was 9.3 +/- 0.9 mSv at low heart rates (<70 bpm) while, the average estimated effective doses of DSCT were 9.1 +/- 1.3 mSv, 8.3 +/- 1.1 mSv, 7.9 +/- 1.1 mSv, 6.9 +/- 0.7 mSv, and 5.9 +/- 1.3 mSv, corresponding to heart rates of 50-59 bpm, 60-69 bpm, 70-79 bpm, 80-89 bpm, and 90-100 bpm. Conclusion: For cardiac CTA, both DSCT and SSCT can get good image quality at low heart rates (<70 bpm) with a similar radiation dose, but, at high heart rates (>70 bpm), DSCT is able to provide robust diagnostic image quality at doses far below that of SSCT. (C) 2008 Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:396 / 400
页数:5
相关论文
共 50 条
  • [41] TRI-PICCS in Single Source and Dual Source CT
    Maass, Clemens
    Hofmann, Christian
    Kachelriess, Marc
    2010 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD (NSS/MIC), 2010, : 2805 - 2810
  • [42] Comparison of image quality and radiation dose of different pulmonary CTA protocols on a 128-slice CT: high-pitch dual source CT, dual energy CT and conventional spiral CT
    Tobias De Zordo
    Klemens von Lutterotti
    Christian Dejaco
    Peter F. Soegner
    Renate Frank
    Friedrich Aigner
    Andrea S. Klauser
    Christoph Pechlaner
    U. Joseph Schoepf
    Werner R. Jaschke
    Gudrun M. Feuchtner
    European Radiology, 2012, 22 : 279 - 286
  • [43] Comparison of image quality and radiation dose of different pulmonary CTA protocols on a 128-slice CT: high-pitch dual source CT, dual energy CT and conventional spiral CT
    De Zordo, Tobias
    von Lutterotti, Klemens
    Dejaco, Christian
    Soegner, Peter F.
    Frank, Renate
    Aigner, Friedrich
    Klauser, Andrea S.
    Pechlaner, Christoph
    Schoepf, U. Joseph
    Jaschke, Werner R.
    Feuchtner, Gudrun M.
    EUROPEAN RADIOLOGY, 2012, 22 (02) : 279 - 286
  • [44] Virtual monochromatic imaging in dual-source dual-energy CT: Radiation dose and image quality
    Yu, Lifeng
    Christner, Jodie A.
    Leng, Shuai
    Wang, Jia
    Fletcher, Joel G.
    McCollough, Cynthia H.
    MEDICAL PHYSICS, 2011, 38 (12) : 6371 - 6379
  • [45] Low kVp imaging for dose reduction in dual-source cardiac CT
    María Luaces
    Scott Akers
    Harold Litt
    The International Journal of Cardiovascular Imaging, 2009, 25 : 165 - 175
  • [46] Low kVp imaging for dose reduction in dual-source cardiac CT
    Luaces, Maria
    Akers, Scott
    Litt, Harold
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2009, 25 : 165 - 175
  • [47] Strategies for Dose-Optimized Imaging in Pediatric Cardiac Dual Source CT
    Kuettner, A.
    Gehann, B.
    Spolnik, J.
    Koch, A.
    Achenbach, S.
    Weyand, M.
    Dittrich, S.
    Uder, M.
    Staatz, G.
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2009, 181 (04): : 339 - 348
  • [48] CT colonography with spectral filtration and advanced modeled iterative reconstruction in the thirdgeneration dual-source CT: image quality, radiation dose and performance in clinical utility
    Liu, Jing-juan
    Xue, Hua-dan
    Liu, Wei
    Yan, Jing
    Pan, Wei-dong
    Li, Bin
    Xu, Kai
    Wang, Yun
    Li, Ping
    Xiao, Yi
    Jin, Zheng-yu
    ACADEMIC RADIOLOGY, 2021, 28 (05) : E127 - E136
  • [49] Temporal resolution and motion artifacts in single-source and dual-source cardiac CT
    Schoendube, Harald
    Allmendinger, Thomas
    Stierstorfer, Karl
    Bruder, Herbert
    Flohr, Thomas
    MEDICAL PHYSICS, 2013, 40 (03)
  • [50] Low-Dose Scan Protocols in Dual-Source CT Coronary Angiography
    Li, Min
    Sun, Gang
    RADIOLOGY, 2012, 263 (03) : 937 - 938