Comparison of dose response functions for EBT3 model GafChromic™ film dosimetry system

被引:28
|
作者
Aldelaijan, Saad [1 ,2 ,3 ,4 ]
Devic, Slobodan [1 ,2 ,5 ]
机构
[1] Jewish Gen Hosp, Radiat Oncol Dept, Montreal, PQ H3T 1E2, Canada
[2] McGill Univ, Med Phys Unit, Montreal, PQ H4A 3J1, Canada
[3] Montreal Neurol Inst, Biol & Biomed Engn Dept, Montreal, PQ H3A 2B4, Canada
[4] King Faisal Specialist Hosp & Res Ctr, Biomed Phys Dept, Riyadh, Saudi Arabia
[5] McGill Univ, Jewish Gen Hosp, Segal Canc Ctr, Montreal, PQ, Canada
基金
加拿大自然科学与工程研究理事会;
关键词
Radiochromic film dosimetry system; Response function; PROTOCOL;
D O I
10.1016/j.ejmp.2018.05.014
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objective: Different dose response functions of EBT3 model GafChromic (TM) film dosimetry system have been compared in terms of sensitivity as well as uncertainty vs. error analysis. We also made an assessment of the necessity of scanning film pieces before and after irradiation. Methods: Pieces of EBT3 film model were irradiated to different dose values in Solid Water (SW) phantom. Based on images scanned in both reflection and transmission mode before and after irradiation, twelve different response functions were calculated. For every response function, a reference radiochromic film dosimetry system was established by generating calibration curve and by performing the error vs. uncertainty analysis. Results: Response functions using pixel values from the green channel demonstrated the highest sensitivity in both transmission and reflection mode. All functions were successfully fitted with rational functional form, and provided an overall one-sigma uncertainty of better than 2% for doses above 2 Gy. Use of pre-scanned images to calculate response functions resulted in negligible improvement in dose measurement accuracy. Conclusion: Although reflection scanning mode provides higher sensitivity and could lead to a more widespread use of radiochromic film dosimetry, it has fairly limited dose range and slightly increased uncertainty when compared to transmission scan based response functions. Double-scanning technique, either in transmission or reflection mode, shows negligible improvement in dose accuracy as well as a negligible increase in dose uncertainty. Normalized pixel value of the images scanned in transmission mode shows linear response in a dose range of up to 11 Gy.
引用
收藏
页码:112 / 118
页数:7
相关论文
共 50 条
  • [1] A characterisation of EBT3 Gafchromic film for relative and absolute dosimetry
    Billas, I.
    Bouchard, H.
    Subiel, A.
    Silvestre, I.
    Duane, S.
    RADIOTHERAPY AND ONCOLOGY, 2017, 123 : S414 - S414
  • [2] Precise EBT3 Gafchromic film dosimetry for Grid therapy
    Gholami, Somayeh
    Nedaie, Hassan Ali
    Meigooni, Ali S.
    RADIATION MEASUREMENTS, 2019, 121 : 69 - 76
  • [3] Ion beam dosimetry using Gafchromic EBT3 film
    Hassan, M. G.
    El-Saftawy, A. A.
    Soliman, B. A.
    Abdelrahman, M. M.
    Abdelmageed, K. E.
    Hassouba, M. A.
    APPLIED PHYSICS A-MATERIALS SCIENCE & PROCESSING, 2024, 130 (06):
  • [4] Multichannel absolute film dosimetry for EBT3 GafChromic films
    Ventura, T.
    Lopes, M. C.
    Ferreira, B. C.
    RADIOTHERAPY AND ONCOLOGY, 2014, 111 : S169 - S169
  • [5] Raman scattering for dosimetry using GAFCHROMIC EBT3 radiochromic dosimetry film
    Talarico, Olga S.
    Krylova, Tatyana A.
    Melnik, Nikolay N.
    MEDICAL PHYSICS, 2019, 46 (04) : 1883 - 1887
  • [6] Dosimetric accuracy of Gafchromic EBT2 and EBT3 film for in vivo dosimetry
    Moylan, Rebecca
    Aland, Trent
    Kairn, Tanya
    AUSTRALASIAN PHYSICAL & ENGINEERING SCIENCES IN MEDICINE, 2013, 36 (03) : 331 - 337
  • [7] Dosimetric accuracy of Gafchromic EBT2 and EBT3 film for in vivo dosimetry
    Rebecca Moylan
    Trent Aland
    Tanya Kairn
    Australasian Physical & Engineering Sciences in Medicine, 2013, 36 : 331 - 337
  • [8] Polarized dosimetry method for Gafchromic EBT3
    Perez Azorin, Jose Fernando
    Ramos Garcia, Luis Isaac
    Maza Ozcoidi, Diego
    Almansa, Julio F.
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2016, 32 (08): : 972 - 980
  • [9] Feasibility of Establishing a National Postal Dosimetry System Using EBT3 Gafchromic Film
    Abdel-Rahman, W.
    Mohammed, I.
    Bamajboor, S.
    MEDICAL PHYSICS, 2015, 42 (06) : 3431 - 3431
  • [10] Use of the Monte Carlo Method to Relate GAFCHROMIC® EBT3 Film Response to Absorbed Dose for Alpha Particle Dosimetry
    Martinez, Victor Daniel Diaz
    Cyr, Melodie
    Slobodan, Devic
    Tomic, Nada
    Lewis, David F.
    Enger, Shirin A.
    MEDICAL PHYSICS, 2022, 49 (08) : 5653 - 5653