Comparison of dose response functions for EBT3 model GafChromic™ film dosimetry system

被引:28
|
作者
Aldelaijan, Saad [1 ,2 ,3 ,4 ]
Devic, Slobodan [1 ,2 ,5 ]
机构
[1] Jewish Gen Hosp, Radiat Oncol Dept, Montreal, PQ H3T 1E2, Canada
[2] McGill Univ, Med Phys Unit, Montreal, PQ H4A 3J1, Canada
[3] Montreal Neurol Inst, Biol & Biomed Engn Dept, Montreal, PQ H3A 2B4, Canada
[4] King Faisal Specialist Hosp & Res Ctr, Biomed Phys Dept, Riyadh, Saudi Arabia
[5] McGill Univ, Jewish Gen Hosp, Segal Canc Ctr, Montreal, PQ, Canada
基金
加拿大自然科学与工程研究理事会;
关键词
Radiochromic film dosimetry system; Response function; PROTOCOL;
D O I
10.1016/j.ejmp.2018.05.014
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objective: Different dose response functions of EBT3 model GafChromic (TM) film dosimetry system have been compared in terms of sensitivity as well as uncertainty vs. error analysis. We also made an assessment of the necessity of scanning film pieces before and after irradiation. Methods: Pieces of EBT3 film model were irradiated to different dose values in Solid Water (SW) phantom. Based on images scanned in both reflection and transmission mode before and after irradiation, twelve different response functions were calculated. For every response function, a reference radiochromic film dosimetry system was established by generating calibration curve and by performing the error vs. uncertainty analysis. Results: Response functions using pixel values from the green channel demonstrated the highest sensitivity in both transmission and reflection mode. All functions were successfully fitted with rational functional form, and provided an overall one-sigma uncertainty of better than 2% for doses above 2 Gy. Use of pre-scanned images to calculate response functions resulted in negligible improvement in dose measurement accuracy. Conclusion: Although reflection scanning mode provides higher sensitivity and could lead to a more widespread use of radiochromic film dosimetry, it has fairly limited dose range and slightly increased uncertainty when compared to transmission scan based response functions. Double-scanning technique, either in transmission or reflection mode, shows negligible improvement in dose accuracy as well as a negligible increase in dose uncertainty. Normalized pixel value of the images scanned in transmission mode shows linear response in a dose range of up to 11 Gy.
引用
收藏
页码:112 / 118
页数:7
相关论文
共 50 条
  • [41] Feasibility of Gafchromic EBT3 film for measuring out-of-field dose in radiotherapy
    Viren, T.
    Saikkonen, A.
    Niemela, J.
    Keyrilainen, J.
    Salomaa, S.
    Seppala, J.
    RADIOTHERAPY AND ONCOLOGY, 2018, 127 : S1002 - S1003
  • [42] A diffuse reflectance spectrophotometer for radiation dosimetry of EBT3 GAFchromic films
    Piliero, Maria A.
    Pupillo, Francesco
    Presilla, Stefano
    RADIATION MEASUREMENTS, 2022, 154
  • [43] Comparative analysis of dosimetric uncertainty using Gafchromic™ EBT4 and EBT3 films in radiochromic film dosimetry
    Akdeniz, Yucel
    RADIATION PHYSICS AND CHEMISTRY, 2024, 220
  • [44] The combination of the error correction methods of GAFCHROMIC EBT3 film
    Li, Yinghui
    Chen, Lixin
    Zhu, Jinhan
    Liu, Xiaowei
    PLOS ONE, 2017, 12 (07):
  • [45] Gafchromic EBT3 film dosimetry in electron beams - energy dependence and improved film read-out
    Sipila, Petri
    Ojala, Jarkko
    Kaijaluoto, Sampsa
    Jokelainen, Ilkka
    Kosunen, Antti
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2016, 17 (01): : 360 - 373
  • [46] UNLAMINATED GAFCHROMIC EBT3 FILM FOR ULTRAVIOLET RADIATION MONITORING
    Welch, David
    Randers-Pehrson, Gerhard
    Spotnitz, Henry M.
    Brenner, David J.
    RADIATION PROTECTION DOSIMETRY, 2017, 176 (04) : 341 - 346
  • [47] Temperature dependent dose readout of Gafchromic EBT3 and EBT-XD film and clinical relevance in SRT
    Buchauer, K.
    Plasswilm, L.
    Schiefer, J.
    RADIOTHERAPY AND ONCOLOGY, 2017, 123 : S807 - S808
  • [48] Absolute dosimetry with EBT3 Gafchromic films in a pulsed electron beam at high dose-rate
    Jaccard, M.
    Petersson, K.
    Buchillier, T.
    Bailat, C.
    Germond, J. F.
    Moeckli, R.
    Bourhis, J.
    Vozenin, M. C.
    Bochud, F.
    RADIOTHERAPY AND ONCOLOGY, 2016, 119 : S690 - S690
  • [49] Evaluation of the Dose-Rate Dependency of GAFCHROMIC EBT3
    Twork, G.
    Sarfehnia, A.
    MEDICAL PHYSICS, 2013, 40 (06)
  • [50] In vivo dosimetry and shielding disk alignment verification by EBT3 GAFCHROMIC film in breast IOERT treatment
    Severgnini, Mara
    de Denaro, Mario
    Bortul, Marina
    Vidali, Cristiana
    Beorchia, Aulo
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2015, 16 (01): : 112 - 120