Biomechanical design of Less Invasive Stabilization System femoral plates: Computational evaluation of the fracture environment

被引:8
|
作者
Reina-Romo, Esther [1 ]
Giraldez-Sanchez, M. A. [2 ]
Mora-Macias, J. [1 ]
Cano-Luis, P. [2 ]
Dominguez, Jaime [1 ]
机构
[1] Univ Seville, Dept Mech Engn, Seville 41092, Spain
[2] Hosp Univ Virgen del Rocio, Dept Traumatol, Seville, Spain
关键词
Less Invasive Stabilization System; femoral plate; biomechanics; finite element; femoral fracture; TROCHANTERIC GAMMA-NAIL; FINITE-ELEMENT-ANALYSIS; LOCKING PLATE; MECHANICAL CONDITIONS; KNEE ARTHROPLASTY; INTERNAL-FIXATION; FEMUR FRACTURES; SCREW PLACEMENT; LISS; BONE;
D O I
10.1177/0954411914554634
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Less Invasive Stabilization System femoral plates are currently accepted as a suitable fixation technique for supra-intercondylar femoral fractures. However, general agreement does not exist regarding the optimum design of this fixator type. Therefore, the aim of this article is to reduce the intrinsic Less Invasive Stabilization System complications by clarifying, from a biomechanical point of view, how the number of screws, the screw connection type (unicortical or bicortical), or the structured position of the screws can influence the outcome of the fracture site. These studies include a specific finite element analysis that determines how several biomechanical variables, such as the movement at the fracture site, are influenced by the preconditions of bone healing. The results of this study show that the screw type affects the mechanical stabilization of the femur to a greater extent than the material type of the Less Invasive Stabilization System femoral plates. The most significant differences among all the analyzed configurations are observed in the shear interfragmentary strain between screw types. Values are approximately 50% higher with unicortical screws than with bicortical ones.
引用
收藏
页码:1043 / 1052
页数:10
相关论文
共 50 条
  • [41] Minimally invasive screw plates for surgery of unstable intertrochanteric femoral fractures: A biomechanical comparative study
    Ropars, Mickael
    Mitton, David
    Skalli, Wafa
    CLINICAL BIOMECHANICS, 2008, 23 (08) : 1012 - 1017
  • [42] Biomechanical Evaluation of an Interfacet Joint Decompression and Stabilization System
    Leasure, Jeremi M.
    Buckley, Jenni
    JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 2014, 136 (07):
  • [43] Computational evaluation of the biomechanical effects of position changes in the femoral neck system on Pauwels type III femoral neck fractures: an in silico study
    Zhang, Xiang
    Zhang, Shenghang
    Zhong, Zhou
    Zhang, Wen
    Xiong, Zhongwei
    FRONTIERS IN BIOENGINEERING AND BIOTECHNOLOGY, 2025, 13
  • [44] The development of the distal femur Less Invasive Stabilization System (LISS)
    Frigg, R
    Appenzeller, A
    Christensen, R
    Frenk, A
    Gilbert, S
    Schavan, R
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2001, 32 : 24 - 31
  • [45] Less invasive stabilization system for the management of proximal tibia fractures
    Devkota P.
    Manandhar H.K.
    Khadka P.B.
    Mainali L.P.
    Khan J.A.
    Acharya B.M.
    Pradhan N.S.
    Shrestha S.K.
    European Journal of Orthopaedic Surgery & Traumatology, 2014, 24 (6) : 993 - 998
  • [46] Technical Problems and Complications in the Removal of the Less Invasive Stabilization System
    Suzuki, Takashi
    Smith, Wade R.
    Stahel, Philip F.
    Morgan, Steven J.
    Baron, Andrea J.
    Hak, David J.
    JOURNAL OF ORTHOPAEDIC TRAUMA, 2010, 24 (06) : 369 - 373
  • [47] Use of the Less Invasive Stabilization System (LISS) in patients with distal femoral (AO33) fractures: a prospective multicenter study
    Michael Schütz
    Mathias Müller
    Pietro Regazzoni
    Dankward Höntzsch
    Christian Krettek
    Christian Van der Werken
    Norbert Haas
    Archives of Orthopaedic and Trauma Surgery, 2005, 125 : 102 - 108
  • [48] Biomechanical Evaluation of Cannulated Screw Optimization for Stabilization of Pauwels Type Femoral Neck Fractures
    Verim, Ozgur
    APPLIED SCIENCES-BASEL, 2024, 14 (07):
  • [49] Use of the Less Invasive Stabilization System (LISS) in patients with distal femoral (AO33) fractures:: a prospective multicenter study
    Schütz, M
    Müller, M
    Regazzoni, P
    Höntzsch, D
    Krettek, C
    Van der Werken, C
    Haas, N
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2005, 125 (02) : 102 - 108
  • [50] Reverse polyaxial less invasive stabilization systems for treatment of femoral intertrochanteric fractures of the distal femur
    Shen, Longxiang
    Li, Xiaolin
    Wang, Tao
    Luo, Congfeng
    Zeng, Bingfang
    Ding, Jian