Minimally invasive screw plates for surgery of unstable intertrochanteric femoral fractures: A biomechanical comparative study

被引:16
|
作者
Ropars, Mickael [1 ,2 ]
Mitton, David [2 ]
Skalli, Wafa [2 ]
机构
[1] Hosp Sud Univ, Orthopaed & Reconstruct Surg Unit, Ctr Trauma, Orthopaed & Reconstruct Surg Dept, F-35056 Rennes, France
[2] CNRS, ENSAM, Biomech Lab, F-75013 Paris, France
关键词
Intertrochanteric fracture; Minimally invasive surgery; Sliding hip screw; Biomechanical study;
D O I
10.1016/j.clinbiomech.2008.04.018
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Background. This Study presents the first biomechanical comparison of two minimal invasive screw plates used in the treatment of intertrochanteric fractures of the femur. Methods. Six fresh cadaveric pairs of human femur were included, following dual energy X-ray absorbsiometry analysis to obtain two cohorts of homogenous femurs. In each pair, unstable four-part trochanteric fractures were created and reduced. In each cohort, one femur was randomly selected to undergo instrumentation using one of the two minimal invasive devices, and the other femur was instrumented using the other device (minimally invasive screw system (MISS) or per cutaneous compression plate (PCCP)). Femurs were positioned at 25 degrees of adduction in order to simulate the anatomical loading during one-legged stance. Biomechanical tests were performed C using a single vertical compressive load applied oil the femoral head. Cycling loading wits applied with three-dimensional fracture motions with stereophotogrammetric analysis and global displacement analysis throughout the cyclic test. Intact femurs after Cyclic loading were tested to failure. Failure mode was diagnosed with macroscopic or radiographic analysis. Findings. Significant difference were detected between PCCP and MISS in sliding of the lap screw. Global vertical displacement of the femoral head during cyclic loading was higher for the PCCP. No statistically significant difference was noted in three-dimensional inter fragmentary displacement and load to failure between these two devices. Failure mode in both devices mainly consisted in fracture impaction, but no cut-out was noted. Interpretation. PCCP and MISS appear to be mechanical devices that may improve clinical outcomes and reduce the risk of co-morbidities associated With Unstable trochanteric fractures without increased risk of mechanical failure. (C) 2008 Elsevier Ltd. All rights reserved.
引用
收藏
页码:1012 / 1017
页数:6
相关论文
共 50 条
  • [1] Minimally Invasive Dynamic Hip Screw Fixation in Stable and Unstable Intertrochanteric Fractures
    Jana, Kanailal
    Jha, Dipak Kumar
    Chakraburtty, Tapas
    Mullick, Sunny Kumar
    Duttagupta, Swarnava
    INTERNATIONAL JOURNAL OF SCIENTIFIC STUDY, 2016, 4 (07) : 71 - 74
  • [2] Comparative biomechanical study of reversed less invasive stabilization system and proximal femoral nail antirotation for unstable intertrochanteric fractures
    Chen Ying
    Liu Shouyao
    Lin Peng
    Wang Yunting
    Wang Jinhui
    Tao Jianfeng
    Cai Rongrong
    中华医学杂志(英文版), 2014, (23) : 4124 - 4129
  • [3] Comparative biomechanical study of reversed less invasive stabilization system and proximal femoral nail antirotation for unstable intertrochanteric fractures
    Chen Ying
    Liu Shouyao
    Lin Peng
    Wang Yunting
    Wang Jinhui
    Tao Jianfeng
    Cai Rongrong
    CHINESE MEDICAL JOURNAL, 2014, 127 (23) : 4124 - 4129
  • [4] Biomechanical study on different lengths of PFNA fixation for unstable intertrochanteric femoral fractures
    Hong, J-B.
    Dan, Y.
    Ouyang, L.
    Liu, Y.
    Xiong, L-M.
    Li, S.
    Feng, X-B.
    Shao, Z-W.
    Yan, C.
    Yang, S. H.
    Liu, P.
    JOURNAL OF MUSCULOSKELETAL & NEURONAL INTERACTIONS, 2017, 17 (04) : 299 - 302
  • [5] A Comparative Study of Screw and Helical Proximal Femoral Nails for the Treatment of Intertrochanteric Fractures
    Park, Jung Ho
    Lee, Yong Seuk
    Park, Jong Woong
    Wang, Joon Ho
    Kim, Jae Gyoon
    ORTHOPEDICS, 2010, 33 (02) : 81 - 85
  • [6] Comparative efficacy of proximal femoral nail vs dynamic condylar screw in treating unstable intertrochanteric fractures
    Mohamed, Ahmed Mohamed Yousif
    Salih, Monzir
    Abdulgadir, Mohanad
    Abbas, Ayman E.
    Turjuman, Duha Lutfi
    WORLD JOURNAL OF ORTHOPEDICS, 2024, 15 (08):
  • [7] Minimally Invasive Surgery for Unstable Pelvic Ring Fractures: Transiliac Rod and Screw Fixation
    Toda, Kazukiyo
    Yagata, Yukihisa
    Kikuchi, Takeshi
    Takigawa, Tomoyuki
    Ito, Yasuo
    ACTA MEDICA OKAYAMA, 2020, 74 (01) : 27 - 32
  • [8] Intramedullary hip screw versus sliding hip screw for unstable intertrochanteric femoral fractures in the elderly
    Harrington, P
    Nihal, A
    Singhania, AK
    Howell, FR
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2002, 33 (01): : 23 - 28
  • [9] Minimally invasive management of unstable proximal femoral extracapsular fractures using reverse LISS femoral locking plates
    Ozkaya, Ufuk
    Bilgili, Fuat
    Kilic, Ayhan
    Parmaksizoglu, Atilla Sancar
    Kabukcuoglu, Yavuz
    HIP INTERNATIONAL, 2009, 19 (02) : 141 - 147
  • [10] Proximal femoral locking plate versus dynamic hip screw for unstable intertrochanteric femoral fractures
    Upadhyay, Sachin
    Raza, H. K. T.
    JOURNAL OF ORTHOPAEDIC SURGERY, 2014, 22 (01) : 130 - 131