Biomechanical design of Less Invasive Stabilization System femoral plates: Computational evaluation of the fracture environment

被引:8
|
作者
Reina-Romo, Esther [1 ]
Giraldez-Sanchez, M. A. [2 ]
Mora-Macias, J. [1 ]
Cano-Luis, P. [2 ]
Dominguez, Jaime [1 ]
机构
[1] Univ Seville, Dept Mech Engn, Seville 41092, Spain
[2] Hosp Univ Virgen del Rocio, Dept Traumatol, Seville, Spain
关键词
Less Invasive Stabilization System; femoral plate; biomechanics; finite element; femoral fracture; TROCHANTERIC GAMMA-NAIL; FINITE-ELEMENT-ANALYSIS; LOCKING PLATE; MECHANICAL CONDITIONS; KNEE ARTHROPLASTY; INTERNAL-FIXATION; FEMUR FRACTURES; SCREW PLACEMENT; LISS; BONE;
D O I
10.1177/0954411914554634
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Less Invasive Stabilization System femoral plates are currently accepted as a suitable fixation technique for supra-intercondylar femoral fractures. However, general agreement does not exist regarding the optimum design of this fixator type. Therefore, the aim of this article is to reduce the intrinsic Less Invasive Stabilization System complications by clarifying, from a biomechanical point of view, how the number of screws, the screw connection type (unicortical or bicortical), or the structured position of the screws can influence the outcome of the fracture site. These studies include a specific finite element analysis that determines how several biomechanical variables, such as the movement at the fracture site, are influenced by the preconditions of bone healing. The results of this study show that the screw type affects the mechanical stabilization of the femur to a greater extent than the material type of the Less Invasive Stabilization System femoral plates. The most significant differences among all the analyzed configurations are observed in the shear interfragmentary strain between screw types. Values are approximately 50% higher with unicortical screws than with bicortical ones.
引用
收藏
页码:1043 / 1052
页数:10
相关论文
共 50 条
  • [1] Biomechanical evaluation of the less invasive stabilization system for the internal fixation of distal femur fractures
    Marti, A
    Fankhauser, C
    Frenk, A
    Cordey, J
    Gasser, B
    JOURNAL OF ORTHOPAEDIC TRAUMA, 2001, 15 (07) : 482 - 487
  • [2] External Fixation Using Femoral Less Invasive Stabilization System Plate in Tibial Proximal Metaphyseal Fracture
    Zhang, Jingwei
    Ebraheim, Nabil
    Li, Ming
    He, Xianfeng
    Liu, Jiayong
    Zhu, Limei
    Yu, Yihui
    CLINICS IN ORTHOPEDIC SURGERY, 2015, 7 (01) : 8 - 14
  • [3] Distal femoral fracture fixation utilizing the Less Invasive Stabilization System (LISS): The technique and early results
    Kregor, PJ
    Stannard, J
    Zlowodzki, M
    Cole, PA
    Alonso, J
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2001, 32 : 32 - 47
  • [4] Comparative biomechanical study of reversed less invasive stabilization system and proximal femoral nail antirotation for unstable intertrochanteric fractures
    Chen Ying
    Liu Shouyao
    Lin Peng
    Wang Yunting
    Wang Jinhui
    Tao Jianfeng
    Cai Rongrong
    CHINESE MEDICAL JOURNAL, 2014, 127 (23) : 4124 - 4129
  • [5] Comparative biomechanical study of reversed less invasive stabilization system and proximal femoral nail antirotation for unstable intertrochanteric fractures
    Chen Ying
    Liu Shouyao
    Lin Peng
    Wang Yunting
    Wang Jinhui
    Tao Jianfeng
    Cai Rongrong
    中华医学杂志(英文版), 2014, (23) : 4124 - 4129
  • [6] Biomechanical Evaluation of Retrograde Intramedullary Stabilization for Femoral Fractures The Effect of Fracture Level
    Goodwin, Ryan
    Mahar, Andrew T.
    Oka, Richard
    Steinman, Suzanne
    Newton, Peter O.
    JOURNAL OF PEDIATRIC ORTHOPAEDICS, 2007, 27 (08) : 873 - 876
  • [7] Less-Invasive Stabilization of Rib Fractures by Intramedullary Fixation: A Biomechanical Evaluation
    Bottlang, Michael
    Helzel, Inga
    Long, William
    Fitzpatrick, Daniel
    Madey, Steven
    JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE, 2010, 68 (05): : 1218 - 1224
  • [8] Comparison of Less Invasive Stabilization System Plate and Retrograde Intramedullary Nail in the Fixation of Femoral Supracondylar Fractures in the Elderly: A Biomechanical Study
    Du, Yu-ren
    Ma, Jian-xiong
    Wang, Shuo
    Sun, Lei
    Wang, Ying
    Lu, Bin
    Bai, Hao-hao
    Hu, Yong-cheng
    Ma, Xin-long
    ORTHOPAEDIC SURGERY, 2019, 11 (02) : 311 - 317
  • [9] Treatment of distal femoral fractures with the Less Invasive Stabilization System (LISS) in paraplegics
    Badke A.
    Höntzsch D.
    Kaps H.-P.
    Weise K.
    European Journal of Trauma, 2005, 31 (5): : 499 - 502
  • [10] Treatment of Distal Femoral Fracture by Minimally Invasive Percutaneous Plate Osteosynthesis: Comparison Between the Dynamic Condylar Screw and the Less Invasive Stabilization System
    Kao, Feng C.
    Tu, Yuan K.
    Su, Juin Y.
    Hsu, Kuo Y.
    Wu, Chin H.
    Chou, Ming C.
    JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE, 2009, 67 (04): : 719 - 726