Initial phantom studies for an office-based low-field MR system for prostate biopsy

被引:4
|
作者
Chiragzada, Selin [1 ]
Hellman, Eva [1 ]
Michael, Duncan [1 ]
Narayanan, Ram [1 ]
Nacev, Aleksandar [1 ]
Kumar, Dinesh [1 ]
机构
[1] Promaxo Inc, Oakland, CA 94607 USA
关键词
Targeted prostate biopsy; Low-field MRI; Office-based MRI; Navigation accuracy; Prostate cancer; MR-guided biopsy; ULTRASOUND; BRACHYTHERAPY; ACCURACY; GUIDANCE; FUSION; TIME;
D O I
10.1007/s11548-021-02364-7
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Purpose Prostate cancer is the second most prevalent cancer in US men, with about 192,000 new cases and 33,000 deaths predicted for 2020. With only a 31% 5-year survival rate for patients with an initial diagnosis of stage-four prostate cancer, the necessity for early screening and diagnosis is clear. In this paper, we present navigation accuracy results for Promaxo's MR system intended to be used in a physician's office for image-guided transperineal prostate biopsy. Methods The office-based low-field MR system was used to acquire images of prostate phantoms with needles inserted through a transperineal template. Coordinates of the estimated sample core locations in the office-based MR system were compared to ground truth needle coordinates identified in a 1.5T external reference scan. The error was measured as the distance between the planned target and the ground truth core center and as the shortest perpendicular distance between the planned target and the ground truth trajectory of the whole core. Results The average error between the planned target and the ground truth core center was 2.57 +/- 1.02 mm, [1.93-3.21] 95% CI. The average error between the planned target to the actual core segment was 2.05 +/- 1.24 mm, [1.53-2.56] 95% CI. Conclusion The average navigation errors were below the clinically significant threshold of 5 mm. The initial phantom results demonstrate the feasibility of the office-based system for prostate biopsy.
引用
收藏
页码:741 / 748
页数:8
相关论文
共 50 条
  • [21] Quantifying Liver Fat Using a Low-Field Unilateral MR System
    von Morze, Cornelius
    Blazey, Tyler
    Conradi, Mark S.
    APPLIED MAGNETIC RESONANCE, 2023, 54 (11-12) : 1365 - 1376
  • [22] Quantifying Liver Fat Using a Low-Field Unilateral MR System
    Cornelius von Morze
    Tyler Blazey
    Mark S. Conradi
    Applied Magnetic Resonance, 2023, 54 : 1365 - 1376
  • [23] Feasibility and preliminary clinical tolerability of low-field MRI-guided prostate biopsy
    Sze, Christina
    Singh, Zorawar
    Punyala, Ananth
    Satya, Poorvi
    Sadinski, Molly
    Narayan, Ramkrishnan
    Nacev, Aleksander
    Kumar, Dinesh
    Adams Jr, John
    Nicholas, Kathryn
    Margolis, Daniel
    Chughtai, Bilal
    PROSTATE, 2023, 83 (07): : 656 - 662
  • [24] Open low-field magnetic resonance (MR) imaging in prostate radiotherapy treatment planning
    Dipasquale, G
    Rouzoud, M
    Nouet, P
    Jargy, C
    Ares, C
    Miralbell, R
    STRAHLENTHERAPIE UND ONKOLOGIE, 2004, 180 : 103 - 103
  • [25] Information integration for field workers and office-based professionals: 3 case studies
    Bauer, M
    Siegel, J
    INFORMATION AND PROCESS INTEGRATION IN ENTERPRISES: RETHINKING DOCUMENTS, 1998, 428 : 95 - 108
  • [26] Assessment of Gradient Nonlinearity Distortions in a Low-Field MR-Linac Using a Modular Large Field of View Phantom
    Nejad-Davarani, S. P.
    Barberi, E.
    Cole, M.
    Glide-Hurst, C.
    MEDICAL PHYSICS, 2018, 45 (06) : E481 - E481
  • [27] Iron oxide magnetic nanoparticles based low-field MR thermometry
    Zhang, Yapeng
    Guo, Silin
    Zhang, Pu
    Zhong, Jing
    Liu, Wenzhong
    NANOTECHNOLOGY, 2020, 31 (34)
  • [28] Initial experience and cancer detection rates of office-based transperineal magnetic resonance imaging-ultrasound fusion prostate biopsy under local anesthesia
    Kozel, Zachary
    Martin, Clay
    Mikhail, David
    Smith, Aaron
    Griffiths, Luke
    Nethala, Daniel
    Vira, Manish
    Schwartz, Michael
    CUAJ-CANADIAN UROLOGICAL ASSOCIATION JOURNAL, 2022, 16 (07): : E350 - E356
  • [29] MR arthrography in chondromalacia patellae diagnosis on a low-field open magnet system
    Harman, M
    Ipeksoy, U
    Dogan, A
    Arslan, H
    Etlik, O
    CLINICAL IMAGING, 2003, 27 (03) : 194 - 199
  • [30] T2 Mapping on Low-field MR System Based on T2NR
    Dai, Ruibin
    Zhao, Cong
    Zhou, Xiaodong
    Xie, Guoxi
    Liu, Xin
    Zheng, Hairong
    2010 3RD INTERNATIONAL CONFERENCE ON BIOMEDICAL ENGINEERING AND INFORMATICS (BMEI 2010), VOLS 1-7, 2010, : 597 - 600