MR arthrography in chondromalacia patellae diagnosis on a low-field open magnet system

被引:12
|
作者
Harman, M
Ipeksoy, U
Dogan, A
Arslan, H
Etlik, O
机构
[1] Univ Yuzuncu Yil, Fac Med, Dept Radiol, Van, Turkey
[2] Univ Yuzuncu Yil, Fac Med, Dept Orthoped Surg, Van, Turkey
关键词
MR arthrography; chondromalacia patellae; low-field MRI;
D O I
10.1016/S0899-7071(02)00521-1
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objective: The purpose of this study was to compare the diagnostic efficacy conventional MRI and MR arthrography (MRA) in the diagnosis of chondromalacia patella (CP) on a low-field open magnet system (LFOMS), correlated with arthroscopy. Subjects and methods: Forty-two patients (50 knees) with pain in the anterior part of the knee were prospectively examined with LFOMS, including T1-weighted, proton density-weighted and T2-weighted sequences. All were also examined T1-weighted MRI after intraarticular injection of dilue gadopentetate dimeglumine. Two observers, who reached a consensus interpretation, evaluated each imaging technique independently. Thirty-six of the 50 facets examined had chondromalacia shown by arthroscopy, which was used as the standard of reference. The sensitivity, specificity and accuracy of each imaging technique in the diagnosis of each stage of CP were determined and compared by using the McNemar two-tailed analysis. Results: Arthroscopy showed that 16 facets were normal. Four (30%) of 13 grade 1 lesions were detected with T1. Four lesions (30%) with T2 and three lesions (23%) with proton-weighted images were detected. Seven (53%) of 13 grade 1 lesions were detected with MRA. Grade 2 abnormalities were diagnosed in two (33%) of six facets with proton density-weighted pulse sequences, two (33%) of six facets with T1-weighted pulse sequences, in three (50%) of six facets with T2-weighted pulse sequences, in five (83%) of six facets with MRA sequences. Grade 3 abnormalities were diagnosed in three (71%) of seven facets with proton density- and T1-weighted images, five (71%) of seven facets with T2-weighted pulse sequences, six (85%) of seven facets with MRA sequences. Grade 4 CP was detected with equal sensitivity with T1-, proton density- and T2-weighted pulse sequences, all showing seven (87%) of the eight lesions. MRA again showed these findings in all eight patients. All imaging techniques were insensitive to grade 1 lesions and highly sensitive to grade 4 lesion, so that no significant difference among the techniques could be shown. Conclusion: All imaging technique studied had high specificity and accuracy in the detection and grading of CP; however, MRA was more sensitive than T1-weighted and proton density-weighted MR imaging on a LFOMS. Although the arthrographic techniques were not significantly better than T2-weighted imaging, the number of false-positive diagnosis was greatest with T2-weighted MRI. (C) 2003 Elsevier Science Inc. All rights reserved.
引用
收藏
页码:194 / 199
页数:6
相关论文
共 50 条
  • [1] DIAGNOSIS OF CHONDROMALACIA PATELLAE USING CT-ARTHROGRAPHY
    REISER, M
    KARPF, PM
    BERNETT, P
    EUROPEAN JOURNAL OF RADIOLOGY, 1982, 2 (03) : 181 - 186
  • [2] CHONDROMALACIA PATELLAE - DIAGNOSIS WITH MR IMAGING
    MCCAULEY, TR
    KIER, R
    LYNCH, KJ
    JOKL, P
    AMERICAN JOURNAL OF ROENTGENOLOGY, 1992, 158 (01) : 101 - 105
  • [3] Low-field MR arthrography of the shoulder: early results using an open 0.2 T MR system.
    Low, R
    Kreitner, KF
    Runkel, M
    Zollner, J
    Thelen, M
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 1998, 168 (04): : 316 - 322
  • [4] DETECTION AND STAGING OF CHONDROMALACIA PATELLAE - RELATIVE EFFICACIES OF CONVENTIONAL NIR IMAGING, MR ARTHROGRAPHY, AND CT ARTHROGRAPHY
    GAGLIARDI, JA
    CHUNG, EM
    CHANDNANI, VP
    KESLING, KL
    CHRISTENSEN, KP
    NULL, RN
    RADVANY, MG
    HANSEN, MF
    AMERICAN JOURNAL OF ROENTGENOLOGY, 1994, 163 (03) : 629 - 636
  • [5] Detection of chondromalacia patellae: Comparison of conventional MRI imaging, and MR and CT arthrography in cadavers
    Rand, T
    Brossmann, J
    Pedowitz, RA
    Ahn, JM
    Haghigi, P
    Resnick, DL
    RADIOLOGY, 1999, 213P : 374 - 374
  • [6] Low-field MR arthrography of the shoulder joint: technique, indications, and clinical results
    K.-F. Kreitner
    R. Loew
    M. Runkel
    J. Zöllner
    M. Thelen
    European Radiology, 2003, 13 : 320 - 329
  • [7] Low-field MR arthrography of the shoulder joint:: technique, indications, and clinical results
    Kreitner, KF
    Loew, R
    Runkel, M
    Zöllner, J
    Thelen, M
    EUROPEAN RADIOLOGY, 2003, 13 (02) : 320 - 329
  • [8] Low-field MR arthrography of the shoulder joint: Results of a prospective, surgically controlled study
    Kreitner, KF
    Loew, R
    Kalden, PR
    Runkel, M
    Thelen, M
    RADIOLOGY, 2002, 225 : 654 - 654
  • [9] Contrast-enhanced breast MR imaging of claustrophobic or oversized patients using an open low-field magnet
    Calabrese, M.
    Brizzi, D.
    Carbonaro, L.
    Chiaramondia, M.
    Kirchin, M. A.
    Sardanelli, F.
    RADIOLOGIA MEDICA, 2009, 114 (02): : 267 - 285
  • [10] Diffusion weighted MR imaging on a low-field open magnet in stroke - Evaluation in a consecutive series of 60 patients
    Somon, T
    Kelekis, A
    Wetzel, S
    Mehdizade, A
    Martin, JB
    Stajzel, R
    Lovblad, KO
    Ruefenacht, DA
    Delavelle, J
    RIVISTA DI NEURORADIOLOGIA, 2003, 16 (05): : 1005 - 1008