MR arthrography in chondromalacia patellae diagnosis on a low-field open magnet system

被引:12
|
作者
Harman, M
Ipeksoy, U
Dogan, A
Arslan, H
Etlik, O
机构
[1] Univ Yuzuncu Yil, Fac Med, Dept Radiol, Van, Turkey
[2] Univ Yuzuncu Yil, Fac Med, Dept Orthoped Surg, Van, Turkey
关键词
MR arthrography; chondromalacia patellae; low-field MRI;
D O I
10.1016/S0899-7071(02)00521-1
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objective: The purpose of this study was to compare the diagnostic efficacy conventional MRI and MR arthrography (MRA) in the diagnosis of chondromalacia patella (CP) on a low-field open magnet system (LFOMS), correlated with arthroscopy. Subjects and methods: Forty-two patients (50 knees) with pain in the anterior part of the knee were prospectively examined with LFOMS, including T1-weighted, proton density-weighted and T2-weighted sequences. All were also examined T1-weighted MRI after intraarticular injection of dilue gadopentetate dimeglumine. Two observers, who reached a consensus interpretation, evaluated each imaging technique independently. Thirty-six of the 50 facets examined had chondromalacia shown by arthroscopy, which was used as the standard of reference. The sensitivity, specificity and accuracy of each imaging technique in the diagnosis of each stage of CP were determined and compared by using the McNemar two-tailed analysis. Results: Arthroscopy showed that 16 facets were normal. Four (30%) of 13 grade 1 lesions were detected with T1. Four lesions (30%) with T2 and three lesions (23%) with proton-weighted images were detected. Seven (53%) of 13 grade 1 lesions were detected with MRA. Grade 2 abnormalities were diagnosed in two (33%) of six facets with proton density-weighted pulse sequences, two (33%) of six facets with T1-weighted pulse sequences, in three (50%) of six facets with T2-weighted pulse sequences, in five (83%) of six facets with MRA sequences. Grade 3 abnormalities were diagnosed in three (71%) of seven facets with proton density- and T1-weighted images, five (71%) of seven facets with T2-weighted pulse sequences, six (85%) of seven facets with MRA sequences. Grade 4 CP was detected with equal sensitivity with T1-, proton density- and T2-weighted pulse sequences, all showing seven (87%) of the eight lesions. MRA again showed these findings in all eight patients. All imaging techniques were insensitive to grade 1 lesions and highly sensitive to grade 4 lesion, so that no significant difference among the techniques could be shown. Conclusion: All imaging technique studied had high specificity and accuracy in the detection and grading of CP; however, MRA was more sensitive than T1-weighted and proton density-weighted MR imaging on a LFOMS. Although the arthrographic techniques were not significantly better than T2-weighted imaging, the number of false-positive diagnosis was greatest with T2-weighted MRI. (C) 2003 Elsevier Science Inc. All rights reserved.
引用
收藏
页码:194 / 199
页数:6
相关论文
共 50 条
  • [41] The low-field permanent magnet electrostatic plasma lens
    Goncharov, A
    Gorshkov, V
    Maslov, V
    Zadorozhny, V
    Brown, I
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2004, 75 (05): : 1662 - 1664
  • [42] MRI of the equine digit with a dedicated low-field magnet
    Choquet, P
    Sick, H
    Constantinesco, A
    VETERINARY RECORD, 2000, 146 (21) : 616 - 617
  • [43] Retrospective 5-Year Analysis of MR-Guided Biopsies in a Low-Field MR System
    Zangos, S.
    Mueller, C.
    Mayer, F.
    Naguib, N. N.
    Nour-Eldin, N-E. A.
    Hansmann, M-L.
    Herzog, C.
    Hammerstingl, R. M.
    Thalhammer, A.
    Mack, M.
    Vogl, T. J.
    Eichler, K.
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2009, 181 (07): : 658 - 663
  • [44] LOW-FIELD ROOM BUILT AT HIGH-FIELD MAGNET LAB
    不详
    PHYSICS TODAY, 1970, 23 (06) : 56 - &
  • [45] Performance of an open low-field MR unit in routine examination of knee lesions and comparison with high field systems
    Vahlensieck, M
    Schnieber, O
    ORTHOPADE, 2003, 32 (02): : 175 - 178
  • [46] High-versus low-field MR imaging
    Tavernier, T
    Cotten, A
    RADIOLOGIC CLINICS OF NORTH AMERICA, 2005, 43 (04) : 673 - +
  • [47] Characterization and 3D correction of geometric distortion in low-field open-magnet MRI
    Viard, Romain
    Betrouni, Nacirn
    Vermandel, Maximilien
    Mordon, Serge
    Rousseau, Jean
    2008 30TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-8, 2008, : 3649 - 3652
  • [48] Intraoperative low-field MR imaging in epilepsy surgery
    Buchfelder, M
    Nimsky, C
    ARQUIVOS DE NEURO-PSIQUIATRIA, 2003, 61 : 115 - 122
  • [49] MaRCoS, an open-source electronic control system for low-field MRI
    Negnevitsky, Vlad
    Vives-Gilabert, Yolanda
    Algarin, Jose M.
    Craven-Brightman, Lincoln
    Pellicer-Guridi, Ruben
    O'Reilly, Thomas
    Stockmann, Jason P.
    Webb, Andrew
    Alonso, Joseba
    Menkuec, Benjamin
    JOURNAL OF MAGNETIC RESONANCE, 2023, 350
  • [50] Comparison and Validation of Distortion Correction on a Low-Field MR-Guided Radiotherapy System
    Gao, Y.
    Pham, J.
    Kalbasi, A.
    Raldow, A.
    Hu, P.
    Yang, Y.
    MEDICAL PHYSICS, 2020, 47 (06) : E414 - E415